Loading...
HomeMy WebLinkAbout Fidelity Westlake Solar 15 FT Berm Option14' ROAD WITH 2' SETBACKS & TURNAROUND WETLANDS WITH 100' SETBACK FLOOD ZONE PARCEL LINE 15' SETBACK FROM FENCE 100' SETBACK FROM PARCEL AC PANEL & TRANSFORMER PAD MOUNT PROPOSED POINT OF INTERCONNECTION IN EXISTING SWITCHYARD (SEE E-102 FOR DETAIL) NEW UNDERGROUND 25KV CIRCUIT IN EXISTING RACEWAYS NEW UNDERGROUND 25KV CIRCUIT IN TRENCHED PVC CONDUIT NEW UNDERGROUND 25KV CIRCUIT IN TRENCHED PVC CONDUIT TREE SHADING 182' 245' 175' 195' FIDELITY WESTLAKE TX - OVERALL ARRAY LAYOUT SCALE: 1"=150' WHEN PRINTED 36" x 24" N on the job and this office must be notified of any variations from the dimensions and conditions shown by these drawings.Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditionswithout the written consent of Ameresco. Visual contact with these plans or specifications shall constitute conclusive evidence of acceptance of these restrictions.shall be copied, disclosed to others, or used in connection with any work or project other than the specified project for which they have been prepared and developedCopyright 2005 Ameresco. The above drawings, specifications, ideas, designs, and arrangements are and shall remain the property of Ameresco and no part thereofCHECKED BY:DATE:DRAWN BY:SCALE:111 Speen Street, Suite 410Framingham, Massachusetts 01701(508) 661-2200REVISIONS:10/10/191" = 150' WHEN PRINTED 36" x 24"E-100 PHOTOVOLTAIC ARRAY LAYOUT3075 kWp DC STC PV ARRAY (2324 kW AC)SINGLE AXIS GROUNDMOUNT PV ARRAYWESTLAKE, TXDESTINY WAYFIDELITY WESTLAKE TXCNSNOT FOR CONSTRUCTION NOTES: 1.SHADING PATTERN IS CALCULATED BASED ON JUNE 21ST FROM 7:30AM TO 4:30PM, FEBRUARY 21ST FROM 9AM TO 3PM, AND DECEMBER 21ST AT NOON, TAKING INTO ACCOUNT SITE LATITUDE AND LONGITUDE. 2.SHADING FOR OBJECTS NOT IMPACTING THE PV SYSTEM IS NOT SHOWN. 3.GROUND SNOW LOAD = XX PSF, BASIC WIND SPEED = XXX MPH (RISK CATEGORY XXX), EXPOSURE TYPE X. 1" = 150' 0 150 300 450 600 750 900 670675680685666667668669671672673674676677678679681682683684686689690692687REVISIONSOFNo.Date App.SHEET NO.K:\16335\16335-0002-00 Fidelity Westlake Solar\2 Design Phase\CAD\Plans\16335-0002-00 PLAN SHEETS.dwg cas2: October 18, 2019© 2019 Jones | Carter JOB NO.: SCALE:DESIGNED BY.: CHECKED BY: Texas Board of Professional Engineers Registration No. F-439 ABCDEF1234 DATE: DRAWN BY: 4500 Mercantile Plaza Drive, Suite 210  Fort Worth, Texas 76137  682.268.2200INTERIM REVIEWNot intended for construction,bidding or permit purposes.P.E. Serial No.:Date:Engineer:94247JON M. KROEHLER, P.E.OCTOBER 18, 2019TEXAS811 NOTIFICATION SYSTEMCALL BEFORE YOU DIG!!!www.texas811.orgTexas811 or 1-800-545-6005CONTRACTOR TO VERIFY ELEVATION AND LOCATIONOF ALL EXISTING UTILITIES PRIOR TOCOMMENCEMENT OF ANY NEW CONSTRUCTIONJBP JMK JBP16335-0002-00 OCTOBER 2019 TOWN OF WESTLAKE BENCHMARK-9THE STATION IS A TOP SECURITY ROD MONUMENT WITH 3 14" ALUMINUM CAP STAMPED "TOWN OFWESTLAKE GPS 9" SET IN WELL WITH AN ALUMINUM ACCESS COVER SET FLUSH WITH GROUND.ELEVATION 678.40, NAD 83, NORTH CENTRAL ZONE 4202.TOWN OF WESTLAKE BENCHMARK-10THE STATION IS A TOP SECURITY ROD MONUMENT WITH 3 14" ALUMINUM CAP STAMPED "TOWN OFWESTLAKE GPS 10" SET IN WELL WITH AN ALUMINUM ACCESS COVER SET FLUSH WITH GROUND.ELEVATION 656.67, NAD 83, NORTH CENTRAL ZONE 4202.100-YEAR FLOOD PLAINALL FLOODPLAIN INFORMATION IN THESE PLANS ARE FOR GRAPHICAL DEPICTION ONLY, AS SCALEDOFF OF FIRM PANEL MAP #48439C0080K, REVISED DATED SEPTEMBER 25, 2009 FOR TARRANTCOUNTY, TEXAS. THIS PROPERTY IS IN ZONE X, AREAS DETERMINED TO BE OUTSIDE THE 0.2%ANNUAL CHANCE FLOODPLAIN.C-6FIDELITY SOLAR FARMONE DESTINY WAY GRADING PLAN OPTION 2 - 15' BERM 1"=100' DRAWN BY:ISSUE DATE:CHECKED BY:TITLESHEETED/TDPROJECTDATEDESCRIPTIONCOPYRIGHT 2016BRIGHTVIEW DESIGN GROUPA6JOB NUMBER:10-18-20191730728MHAGENCY SUBMITTAL 54321654321BCDBCDA1715 18th STSANTA MONICA, CA 90404PH 310.829.4707WWW.BRIGHTVIEW.COMBRIGHTVIEW DESIGN GROUP EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION AND CONSENT OF BRIGHTVIEW DESIGN GROUP. 11/14/2018 AGENCY SUBMITTAL FIDELITY INVESTMENTS FIDELITY WESTLAKE SOLAR 2 DESTINY WAY, WESTLAKE, TX LANDSCAPE DEVELOPMENT PLANSSITE KEY MAPL0.001SEE SHEET L4.101SEE SHEET L4.102 CAPITAL PKWYDESTINY WAYPLANTING SCHEDULETREESYMBOLBOTANICAL NAMECOMMON NAMEEXPECTED SIZE ATINSTALLATIONSPACINGCOMMENTSQUANTITYJUNIPERUS VIRGINIANAEASTERN RED CEDAR3" CALIPERPER PLANBALL & BURLAP29PINUS VIRGINIANAEASTERN WHITE PINE4" CALIPERPER PLANBALL & BURLAP45ILEX OPACAAMERICAN HOLLY4" CALIPERPER PLANBALL & BURLAP48MYRICA CERIFERASOUTHERN WAX MYRTLE4" CALIPERPER PLANBALL & BURLAP28PLANTING SCHEDULESEED MIXHATCHCOMPONENTS:BOTANICAL NAMECOMMON NAMERATIOSCOMMENTSTBDTBD-TBDTBD-NOTES:1.USE DRIP IRRIGATION TO BE USED AROUND ALLTREES AND SHRUBS. IRRIGATION SYSTEM TO TIEINTO EXISTING WELL LOCATED SOUTH OF DAM. NOIRRIGATION TO BE USED IN OR AROUND THESOLAR ARRAY.SCALE:1" = 80'80'160'240' DRAWN BY:ISSUE DATE:CHECKED BY:TITLESHEETED/TDPROJECTDATEDESCRIPTIONCOPYRIGHT 2016BRIGHTVIEW DESIGN GROUPA6JOB NUMBER:10-18-20191730728MHAGENCY SUBMITTAL 54321654321BCDBCDA1715 18th STSANTA MONICA, CA 90404PH 310.829.4707WWW.BRIGHTVIEW.COMBRIGHTVIEW DESIGN GROUP EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION AND CONSENT OF BRIGHTVIEW DESIGN GROUP. 11/14/2018 AGENCY SUBMITTAL FIDELITY INVESTMENTS FIDELITY WESTLAKE SOLAR 2 DESTINY WAY, WESTLAKE, TX LANDSCAPE DEVELOPMENT PLANSSITE PLANTINGPLAN - NORTHL4.101MATCHLINE - SEE SHEET L4.102PLANTING SCHEDULETREESYMBOLBOTANICAL NAMECOMMON NAMEJUNIPERUS VIRGINIANAEASTERN RED CEDARPINUS VIRGINIANAEASTERN WHITE PINEILEX OPACAAMERICAN HOLLYMYRICA CERIFERASOUTHERN WAX MYRTLESCALE:1" = 40'40'80'120'PROPOSED BERMAREA TO BE SEEDEDWITH MEADOW MIX DRAWN BY:ISSUE DATE:CHECKED BY:TITLESHEETED/TDPROJECTDATEDESCRIPTIONCOPYRIGHT 2016BRIGHTVIEW DESIGN GROUPA6JOB NUMBER:10-18-20191730728MHAGENCY SUBMITTAL 54321654321BCDBCDA1715 18th STSANTA MONICA, CA 90404PH 310.829.4707WWW.BRIGHTVIEW.COMBRIGHTVIEW DESIGN GROUP EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION AND CONSENT OF BRIGHTVIEW DESIGN GROUP. 11/14/2018 AGENCY SUBMITTAL FIDELITY INVESTMENTS FIDELITY WESTLAKE SOLAR 2 DESTINY WAY, WESTLAKE, TX LANDSCAPE DEVELOPMENT PLANSSITE PLANTINGPLAN - SOUTHL4.102MATCHLINE - SEE SHEET L4.101PLANTING SCHEDULETREESYMBOLBOTANICAL NAMECOMMON NAMEJUNIPERUS VIRGINIANAEASTERN RED CEDARPINUS VIRGINIANAEASTERN WHITE PINEILEX OPACAAMERICAN HOLLYMYRICA CERIFERASOUTHERN WAX MYRTLEL4.201SCALE:1" = 40'40'80'120'PROPOSED BERMAREA TO BE SEEDEDWITH MEADOW MIXAREA TO BE SEEDEDWITH MEADOW MIX DRAWN BY:ISSUE DATE:CHECKED BY:TITLESHEETED/TDPROJECTDATEDESCRIPTIONCOPYRIGHT 2016BRIGHTVIEW DESIGN GROUPA6JOB NUMBER:10-18-20191730728MHAGENCY SUBMITTAL 54321654321BCDBCDA1715 18th STSANTA MONICA, CA 90404PH 310.829.4707WWW.BRIGHTVIEW.COMBRIGHTVIEW DESIGN GROUP EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO A THIRD PARTY WITHOUT FIRST OBTAINING THE WRITTEN PERMISSION AND CONSENT OF BRIGHTVIEW DESIGN GROUP. 11/14/2018 AGENCY SUBMITTAL FIDELITY INVESTMENTS FIDELITY WESTLAKE SOLAR 2 DESTINY WAY, WESTLAKE, TX LANDSCAPE DEVELOPMENT PLANSTYPICAL SEEDMIX PLANENLARGEMENTL4.201PLANTING SCHEDULESEED MIXHATCHCOMPONENTS:BOTANICAL NAMECOMMON NAMETBDTBDACCESS ROADSCALE:1" = 10'10'20'30' WESTLAKE SOLAR FARM SCREENING STUDY 2019-10-16 Key is that hedgerows are tailored to their ecosystem with more or fewer conifers, different tree and shrub species, and dif- ferent compositions of layers. Some hedgerows are planted on berms or banks, some have ditches or fences along the side; some are still laid, trimmed, coppiced and pollarded, some leave tall standard trees at intervals or corners. Layers and species diversity is fundamentally important. DRAWN BY: ISSUE DATE: CHECKED BY: TITLE SHEET ED/TDPROJECTDATEDESCRIPTION COPYRIGHT 2016 BRIGHTVIEW DESIGN GROUP A 6 JOB NUMBER: 10-18-2019 1730728 MHAGENCY SUBMITTAL54321 654321 B C D B C D A 1715 18th ST SANTA MONICA, CA 90404 PH 310.829.4707 WWW.BRIGHTVIEW.COM BRIGHTVIEW DESIGN GROUP EXPRESSLY RESERVESITS COMMON LAW COPYRIGHT AND OTHER PROPERTYRIGHTS IN THESE PLANS. THESE PLANS ARE NOT TO BEREPRODUCED, CHANGED, OR COPIED IN ANY FORM ORMANNER WHATSOEVER, NOR ARE THEY TO BEASSIGNED TO A THIRD PARTY WITHOUT FIRSTOBTAINING THE WRITTEN PERMISSION AND CONSENTOF BRIGHTVIEW DESIGN GROUP.11/14/2018AGENCY SUBMITTALFIDELITY INVESTMENTSFIDELITY WESTLAKE SOLAR2 DESTINY WAY,WESTLAKE, TXLANDSCAPE DEVELOPMENT PLANSSITE KEY MAP L0.001SEE SHEET L4.101SEE SHEET L4.102CAPITAL PKWY DESTINY WAY PLANTING SCHEDULE TREE SYMBOL BOTANICAL NAME COMMON NAME EXPECTED SIZE AT INSTALLATION SPACING COMMENTS QUANTITY JUNIPERUS VIRGINIANA EASTERN RED CEDAR 3" CALIPER PER PLAN BALL & BURLAP 29 PINUS VIRGINIANA EASTERN WHITE PINE 4" CALIPER PER PLAN BALL & BURLAP 45 ILEX OPACA AMERICAN HOLLY 4" CALIPER PER PLAN BALL & BURLAP 48 MYRICA CERIFERA SOUTHERN WAX MYRTLE 4" CALIPER PER PLAN BALL & BURLAP 28 PLANTING SCHEDULE SEED MIX HATCH COMPONENTS: BOTANICAL NAME COMMON NAME RATIOS COMMENTS TBD TBD - TBD TBD - NOTES: 1.USE DRIP IRRIGATION TO BE USED AROUND ALL TREES AND SHRUBS. IRRIGATION SYSTEM TO TIE INTO EXISTING WELL LOCATED SOUTH OF DAM. NO IRRIGATION TO BE USED IN OR AROUND THE SOLAR ARRAY. SCALE:1" = 80' 80'160'240' ABERM & HEDGEROW SOLAR FARM SECTION A SECTION B B