Loading...
HomeMy WebLinkAboutStaff Report Entrada Preliminary Plat presentationSTAFF REPORT TO PLANNING & ZONING COMMISSION/TOWN COUNCIL ENTRADA PRELIMINARY PLAT II. Recommendations Related to the Submitted Preliminary Plat for PD1-2 (Entrada) Staff recommends approval of this Preliminary Plat subject to the following stipulations: 1.Add a note to the Preliminary Plat stating that all public infrastructure, with the exception of water, sewer, and Town duct bank, will be maintained by the Developer and/or HOA and these items will be described in detail in the Developer’s Agreement for this property referred to in Recommendation No. 3 below. 2. This Preliminary Plat does not reflect compliance with the Engineering Design Standards adopted by the Town of Westlake. Engineering Design Standards may be approved for the PD1-2 Zoning District that amend the adopted Engineering Design Standards for the PD1-2 Zoning District only. Prior to approval of this Preliminary Plat by the Town Council, the developer must submit engineering Design Standards for approval by the Town Council as part of the Development Plan. 3. The Preliminary Plat approval is conditioned upon compliance with the Developer’s Agreement for the PD1-2 Development. Said Developer’s Agreement should be approved at or prior to consideration of the Preliminary Plat for approval. STAFF REPORT TO PLANNING & ZONING COMMISSION/TOWN COUNCIL ENTRADA PD SITE PLAN LOT 1 II. Recommendations Related to the Submitted Preliminary Plat for PD1-2 (Entrada) Staff recommends approval of this PD Site Plan for PD1-2 Entrada, Lot 1 subject to the following stipulations: 1.Approval is subject to the building design and architecture as submitted to the P&Z at this meeting. This would include granting the variance that the Applicant/Developer is request to the Town’s building articulation requirements on the building’s side closest SH114. 2. Add a note on the site plan requiring cross access for vehicular traffic on all abutting tracts. 3.While not requiring a solid waste collection (dumpster) location on this Site Plan, add a stipulation that solid waste collection for this Site Plan will be addressed in a joint (i.e consolidated) solid waste collection point for this and adjacent tracts which will be a part of the consideration for approval of Site Plans for the adjacent tracts. 4.A lighting plan must be submitted for this Site Plan that meets the requirements of the Section 14 of zoning ordinance for this site (Ordinance No. 703) as well as Chapter 102 of the Town’s Code of Ordinances. 5.All electrical, plumbing, and mechanical equipment, piping, and metering shall be screened from view. When screening is not possible, painting to match the exterior of the portion of the building in closest proximity to the above mentioned items is required.