Loading...
HomeMy WebLinkAboutRes 18-13 Approving a Site Plan in Planned Development PD 3-11 for Spec's Addition TOWN OF WESTLAKE RESOLUTION NO. 18-13 A RESOLUTION OF THE TOWN COUNCIL OF THE TOWN OF WESTLAKE, TEXAS, APPROVING AND AMENDING A PLANNED DEVELOPMENT SITE PLAN OF AN APPROXIMATELY 2.044-ACRE PORTION OF PLANNED DEVELOPMENT DISTRICT 3,PLANNING AREA 11 (PD 3-11), ESTABLISHED BY ORDINANCE 593 FOR THE PROPERTY GENERALLY LOCATED AT THE NORTHWEST CORNER OF SH-170 AND US HWY 377, COMMONLY KNOWN AS WESTLAKE CORNERS NORTH SUBDIVISION. THE PD SITE PLAN SHOWS AN ADDITION TO THE SPEC'S WINES, SPIRITS & FINER FOODS LOCATED MORE SPECIFICALLY AT 2431 US HWY 377. WHEREAS,the Town of Westlake, Texas is a general law municipality; and WHEREAS, Ordinance 593 established Planned Development District 3, Planning Area 11 (PD3-11); and WHEREAS, Resolution 10-44 established the site plan for the original Spec's Wines, Spirits and Finer Foods store located at 2431 US Hwy 377; and WHEREAS, the Planning and Zoning Commission voted unanimously to approve this site plan on March 12, 2018; and WHEREAS, the Town Council finds that the passage of this Resolution is in the best interest of the citizens of Westlake. NOW, THEREFORE,BE IT RESOLVED BY THE TOWN COUNCIL OF THE TOWN OF WESTLAKE, TEXAS: SECTION 1: That, all matters stated in the Recitals hereinabove are found to be true and correct and are incorporated herein by reference as if copied in their entirety. SECTION 2: That the Town of Westlake Town Council does hereby approve the Planned Development Site Plan, attached as Exhibit A, subject to the following conditions: a) All comments from the property owner's association must be addressed before the issuance of any building permits for the Spec's Addition. b) The applicant must receive written approval from the property owner's association (Hillwood Properties) before the issuance of any building permits for the Spec's Addition. c) Lighting fixtures must reduce the number of lumens per lamp in order to reduce the number of foot-candles at the property lines where appropriate. Resolution 18-13 Page 1 of 2 d) The retail fagade signage and business monument signage must exclude the Spec's Rabbit/Bunny logo to match the already existing signage on the store. SECTION 3: If any portion of this Resolution shall, for any reason, be declared invalid by any court of competent jurisdiction, such invalidity shall not affect the remaining provisions hereof and the Council hereby determines that it would have adopted this Resolution without the invalid provision. SECTION 4: That this resolution shall become effective from and after its date of passage. PASSED AND APPROVED ON THIS 26TH DAY OF MARCH 2018. ATTEST: Laura L. Wheat, Mayor 71�/ l—fie"� BGG Kellyl Edwards,-Town Secretary Thomas E. Arymr, To n Manager APPROVE,D AS TOoF.WES � `mow L. anton Lo yTbvrm Attorney �5 Resolution 18-13 Page 2 of 2 5 6 6 6 2 8 10' B.L .DENTON HIGHWAY(U.S. HIGHWAY 377)( VARIABLE WIDTH RIGHT-OF-WAY )N 71°1 8 ' 3 4 " W 1 9 8 . 9 7 ' S 71°1 8 ' 3 4 " E 3 3 8 . 1 8 ' N 71° 1 8 ' 3 4 " W 52.00'L1L230' B.L.50' B.L.LOT 2, B L O C K 1 46,020 S Q . F T . / 1 . 0 5 6 A C . LOT 1, B L O C K 1 WEST L A K E C O R N E R S N O R T H COUN T Y C L E R K ' S F I L E N O . D2110 3 4 1 8 5 , R . P . R . T . C . T . HILL W O O D A L L I A N C E RESID E N T I A L , L . P . , a Texa s l i m i t e d p a r t n e r s h i p COUN T Y C L E R K ' S F I L E N O . D2051 7 9 1 0 8 , R . P . R . T . C . T . HW 24 2 1 L A N D , L . P . , a Texa s l i m i t e d p a r t n e r s h i p COUN T Y C L E R K ' S F I L E N O . D2091 8 1 3 3 6 , R . P . R . T . C . T . FIRE L A N E FIRE L A N E FIRE LANEFIRE LANEFIRE LANE FIRE LANE (BASIS OF BEARINGS)N 24°25'10" E 251.25'N 71°1 8 ' 3 4 " W 119.27 'CV17 12 EXISTI N G STOR E 7,500 S . F . PROP O S E D ADDITI O N 4,800 S . F . 6 3 7 6 6 6TEXAS AND PACIFIC RAILROAD( 100' RIGHT-OF-WAY )5 4 1 1 2 1 26 5 3 7 7 77 8 9 7 LINE DATA L1 S 18°41'26" W 12.04' L2 N 18°41'26" E 12.04' CURVE DATA NO. RADIUS LENGTH DELTA CHORD CV1 5664.36' 250.11' 02°31'47" N17°05'29"E 250.09' VICINITY MAP N.T.S. C3.0SITE PLAN1 INCH = 30 FEET GRAPHIC SCALE 0 303015 VICINITY MAP N.T.S. SITE PLAN SPECS WINE & SPRITS WESTCOAST HIGHWAY FIREBRAND ADDITION BLOCK 1 LOT 2 2.044 ACRES OUT OF THE WILLIAM HUFF SURVEY, ABSTRACT NO 648 TOWN OF WESTLAKE, TARRANT COUNTY, TEXAS FEBRUARY 2018 SITE DATA TABLE ZONING PLANNED DEVELOPMENT USE RETAIL ACRES 2.044 AC. LAND AREA 89,022 S.F. BUILDING SQUARE FEET 12,300 S.F. LOT COVERAGE 16.78% FLOOR AREA RATIO 0.17:1 MAX. BLDG. HEIGHT (FEET/STORIES) 28'-0" / 1-STORY IMPERVIOUS SURFACE 60,030 S.F. (67%) LANDSCAPE AREA 28,992 S.F. (33%) PARKING REQUIREMENT 62 SPACES (1:200 S.F.) PARKING PROVIDED 86 SPACES HANDICAP PARKING PROVIDED 3 SPACES SITE Front StLitsey Rd Independence PkwyOttinger RdTHESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.comCAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSSITE PLAN KEYNOTES: CONSTRUCT 6" CURB & GUTTER CONSTRUCT 6" CONCRETE PAVEMENT SECTION (RE: GEOTECH) INSTALL 4" CONCRETE SIDEWALK INSTALL HANDICAP VAN AND CAR SIGN (RE: A.D.A. PLAN) 4" WHITE PAVEMENT SOLID PARKING STRIPES HANDICAP VAN PARKING STANDARD AREA LIGHT POLE (RE: PHOTOMETRIC PLAN) INSTALL NEW MAILBOX PER HILLWOOD RECOMMENDATION INSTALL NEW TRAFFIC DIRECTIONAL STRIPING 1 3 4 5 6 7 2 GENERAL NOTES 1. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR HIS MEANS AND METHODS OF CONSTRUCTION, JOB SITE CONDITIONS AND JOB SITE SAFETY, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO WORKING HOURS. THE CONTRACTOR SHALL SAVE, PROTECT, INDEMNIFY DEFEND AND HOLD HARMLESS THE OWNER, THE ARCHITECT AND THE ENGINEER FROM ANY CLAIM OF LIABILITY, REAL OR ALLEGED, ARISING OUT OF THE PERFORMANCE OF ANY WORK ON THIS PROJECT. THE CONTRACTOR SHALL NAME THE OWNER, THE ARCHITECT AND THE ENGINEER AS "ADDITIONAL INSURED" ON HIS INSURANCE POLICIES. 2. EXISTING ABOVE GROUND UTILITIES HAVE BEEN SHOWN BASED ON INFORMATION SHOWN ON A SURVEY OF THE PROPERTY. UNDERGROUND UTILITIES ARE SHOWN BASED ON RECORDED DATA AND MAY NOT BE COMPLETE OR EXACT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATIONS AND DEPTHS OF ALL ABOVE GROUND AND UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING ABOVE GROUND OR UNDERGROUND UTILITIES, INCLUDING THOSE NOT SHOWN ON THE PLANS. THE CONTRACTOR IS ADVISED TO CONTACT THE TOWN AND ALL FRANCHISE UTILITY COMPANIES, EASEMENT HOLDERS, ETC. AT LEAST 48 HOURS PRIOR TO BEGINNING EXCAVATION IN THE VICINITY OF ANY UNDERGROUND UTILITY. 3. THE CONTRACTOR SHALL COMPLY WITH ALL BUILDING CODES AND REGULATIONS, FEDERAL, STATE, COUNTY, AND TOWN SAFETY CODES AND INSPECTION REQUIREMENTS. 4. THE CONTRACTOR SHALL PROVIDE DUST PROTECTION DURING CONSTRUCTION. ALL TRASH AND DEBRIS SHALL BE PICKED UP AT ALL TIMES. COMMERCIAL CONSTRUCTION DEBRIS/SOLID WASTE HAULER PERMIT REQUIRED. 170 170 114 114Henrietta Creek Rd Dove Rd Otti n g e r R d 377 377 Roanoke Rd8 9 Resolution 18-13 SITE Front StLitsey Rd Independence PkwyOttinger Rd170 170Henrietta Creek Rd 377 377 Roanoke RdOt t i n g e r R d THESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.comCAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSSHEET INDEX C1.0 COVER SHEET REPLAT ALTA SURVEY C2.0 DEMOLITION PLAN C3.0 SITE PLAN C4.0 DIMENSION CONTROL PLAN C5.0 UTILITY PLAN C6.0 GRADING PLAN C6.1 GRADING CUT/FILL ANALYSIS C7.0 PAVING PLAN C7.1 PAVING DETAILS C8.0 A.D.A. PLAN C9.0 DRAINAGE AREA MAP C10.0 EROSION CONTROL PLAN C11.0 EROSION CONTROL DETAILS L1.0 LANDSCAPE PLAN L1.1 LANDSCAPE SPECIFICATIONS L2.0 IRRIGATION PLAN L2.1 IRRIGATION SPECIFICATIONS SPEC'S WINE & SPIRITS CIVIL CONSTRUCTION PLANS WEST COAST HIGHWAY FIREBRAND ADDITIONLOT 2R, BLOCK 12341 U.S. 377 TOWN OF WESTLAKE, TEXAS 76262 COVER SHEETENGINEER/APPLICANT THE DIMENSION GROUP Firm Registration # F-8396 10755 Sandhill Road Dallas, Texas 75238 Contact: Sherrelle R. Diggs, PE Tel:(214) 343-9400 DEVELOPER WEST COAST HIGHWAY, LLC 31351 Rancho Viejo Road Suite 105 San Juan Capistrano, CA 92651 Contact: Kent McNaughton Tel:(949) 542-4300 SURVEYOR TEXAS HERITAGE SURVEYING, LLC 10610 Metric Drive Suite 124 Dallas, Texas 75243 Contact: Doug R. Stewart, R.P.L.S. Tel:(214) 340-9700 C1.0 REVIEWED BY: TOWN ENGINEER TOWN ENGINEER Resolution 18-13 Resolution 18-13 FIRE LANEFIRE LANEFIRE L A N E FIRE L A N E FIRE L A N E FIRE LA N E FIRE LANEFIRE LANEC2.0DEMOLITION PLAN 1 INCH = 30 FEETGRAPHIC SCALE0303015DEMOLITION KEYNOTES:EXISTING SIDEWALK, CONCRETE CURB AND PAVEMENT TO BEREMOVED.EXISTING 30' CONCRETE PAVEMENT TO BE REMOVED.EXISTING SIGNS TO BE REMOVED.EXISTING DUMPSTER ENCLOSURE TO BE REMOVED.EXISTING TREES TO ME REMOVED AND/OR RELOCATED.EXISTING LIGHT POLE TO BE REMOVED.EXISTING CLEAN-OUT TO BE REMOVEDEXISTING IRRIGATION VALVES TO BE REMOVED.EXISTING ASPHALT ROAD TO BE REMOVEDEXISTING MAILBOX TO BE REMOVED12345THESE PLANS ARE INSTRUMENTS OFPROFESSIONAL SERVICE AND ARE PROTECTEDBY COMMON LAW, STATUTORY AND OTHERRESERVED RIGHTS INCLUDING COPYRIGHT.THEY MAY NOT BE REPRODUCED OR USEDFOR ANY PURPOSE WITHOUT THE WRITTENCONSENT OF THE DIMENSION GROUP.SHEETNo. DATE REVISION DESCRIPTION project no.:drawn: approved:date: ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING 10755 SANDHILL ROAD, DALLAS, TEXAS 75238 TEL: 214-343-9400 www.dimensiongrp.com CAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R 16-703 02/12/18 2341 U.S. 377TOWN OF WESLAKE, TEXAS 76262 LOT 2R, BLOCK 1 WESTCOAST HIGHWAY FIREBRAND ADDITION SPEC'S WINE & SPIRITS 678910Resolution 18-13 5 6 LOT 2, B L O C K 1 46,020 S Q . F T . / 1 . 0 5 6 A C . FIRE L A N E FIRE L A N E FIRE LANEFIRE LANEFIRE LANE FIRE LANE 7 12 PROP O S E D ADDITI O N 4,800 S . F . 6 3 7 6 6 6 5 4 1 1 2 1 26 5 3 7 7 7 7 8 9 7 VICINITY MAP N.T.S. C3.0SITE PLAN1 INCH = 30 FEET GRAPHIC SCALE 0 303015 VICINITY MAP N.T.S. SITE PLAN SPECS WINE & SPRITS WESTCOAST HIGHWAY FIREBRAND ADDITION BLOCK 1 LOT 2 2.044 ACRES OUT OF THE WILLIAM HUFF SURVEY, ABSTRACT NO 648 TOWN OF WESTLAKE, TARRANT COUNTY, TEXAS FEBRUARY 2018 SITE DATA TABLE ZONING PLANNED DEVELOPMENT USE RETAIL ACRES 2.044 AC. LAND AREA 89,022 S.F. BUILDING SQUARE FEET 12,300 S.F. LOT COVERAGE 16.78% FLOOR AREA RATIO 0.17:1 MAX. BLDG. HEIGHT (FEET/STORIES) 28'-0" / 1-STORY IMPERVIOUS SURFACE 60,030 S.F. (67%) LANDSCAPE AREA 28,992 S.F. (33%) PARKING REQUIREMENT 62 SPACES (1:200 S.F.) PARKING PROVIDED 86 SPACES HANDICAP PARKING PROVIDED 3 SPACES THESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.comCAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSSITE PLAN KEYNOTES: CONSTRUCT 6" CURB & GUTTER CONSTRUCT 6" CONCRETE PAVEMENT SECTION (RE: GEOTECH) INSTALL 4" CONCRETE SIDEWALK INSTALL HANDICAP VAN AND CAR SIGN (RE: A.D.A. PLAN) 4" WHITE PAVEMENT SOLID PARKING STRIPES HANDICAP VAN PARKING STANDARD AREA LIGHT POLE (RE: PHOTOMETRIC PLAN) INSTALL NEW MAILBOX PER HILLWOOD RECOMMENDATION INSTALL NEW TRAFFIC DIRECTIONAL STRIPING 1 3 4 5 6 7 2 377 377 8 9 Resolution 18-13 C4.0DIMENSION CONTROL PLAN1 INCH = 30 FEET GRAPHIC SCALE 0 303015 HORIZONTAL CONTROL NOTES: 1. DIMENSIONS ARE MEASURED TO BACK OF CURB AS SHOWN. IF IN DOUBT AS TO THE INTENT OF ANY DIMENSION, CONTACT THE ENGINEER/ARCHITECT FOR A CLARIFICATION. 2. REFER TO ARCHITECTURAL FLOOR PLAN FOR EXACT BUILDING DIMENSIONS. 3. STREET LIGHTS SHALL BE INSTALLED 3-1/2' TO 4' BEHIND BACK OF CURB AS REQUIRED BUT SHALL NOT ENCROACH ON ANY SIDEWALK, OR IN ANY UTILITY EASEMENT OR RIGHT-OF-WAY. THESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.comCAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSResolution 18-13 10' B.L .DENTON HIGHWAY(U.S. HIGHWAY 377)( VARIABLE WIDTH RIGHT-OF-WAY )30' B.L.50' B.L.FIRE L A N E FIRE L A N E FIRE LANEFIRE LANEFIRE LANE FIRE LANE TEXAS AND PACIFIC RAILROAD( 100' RIGHT-OF-WAY )WATER METER SCHEDULE UTILITY NOTES: 1. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR HIS MEANS AND METHODS OF CONSTRUCTION, JOB SITE CONDITIONS AND JOB SITE SAFETY, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO WORKING HOURS. THE CONTRACTOR SHALL SAVE, PROTECT, INDEMNIFY, DEFEND AND HOLD HARMLESS THE OWNER, THE ARCHITECT AND THE ENGINEER FROM ANY CLAIM OF LIABILITY, REAL OR ALLEGED, ARISING OUT OF THE PERFORMANCE OF ANY WORK ON THIS PROJECT. THE CONTRACTOR SHALL NAME THE OWNER, THE ARCHITECT AND THE ENGINEER AS "ADDITIONAL INSURED" ON HIS INSURANCE POLICIES. 2. EXISTING ABOVE GROUND UTILITIES HAVE BEEN SHOWN BASED ON INFORMATION SHOWN ON A SURVEY OF THE PROPERTY BY OTHERS. UNDERGROUND UTILITIES ARE SHOWN BASED ON RECORD DATA AND MAY NOT BE COMPLETE OR EXACT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATIONS AND DEPTHS OF ALL ABOVE GROUND AND UNDERGROUND UTILITIES AND ESTABLISHING THEIR EXACT LOCATION AND DEPTH PRIOR TO SETTING ANY FINISH GRADE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING ABOVE GROUND OR UNDERGROUND UTILITIES, INCLUDING THOSE NOT SHOWN ON THE PLANS. THE CONTRACTOR IS ADVISED TO CONTACT THE CITY AND ALL FRANCHISE UTILITY COMPANIES, EASEMENT HOLDERS, ETC. AT LEAST 48 HOURS PRIOR TO BEGINNING EXCAVATION IN THE VICINITY OF ANY UNDERGROUND UTILITY. 3. WHEN WATER AND SEWER LINES ARE INSTALLED IN PROXIMITY TO ONE ANOTHER, SUCH INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE RULES AND REGULATIONS OF THE TEXAS COMMISSION ON ENVIRONMENTAL QUALITY AND THE TEXAS DEPARTMENT OF HEALTH. SPECIAL ATTENTION IS CALLED TO REQUIREMENTS FOR BOTH LATERAL AND VERTICAL SEPARATION BETWEEN WATER AND SEWER FACILITIES. 4. THIS PROJECT TO BE BUILT IN ACCORDANCE WITH WESTLAKE TOWN STANDARDS, SPECIFICATIONS AND DETAILS FOR WATER AND SEWER CONSTRUCTION. 5. THE CONTRACTOR SHALL COMPLY WITH ALL BUILDING CODES AND REGULATIONS, FEDERAL STATE, COUNTY AND CITY SAFETY CODES AND INSPECTION REQUIREMENTS. 6. THE CONTRACTOR SHALL PROVIDE DUST PROTECTION DURING CONSTRUCTION. ALL TRASH AND DEBRIS SHALL BE PICKED UP AT ALL TIMES. 7. TRENCH SAFETY: IF ANY TRENCH ON THIS JOB SITE, INCLUDING OPEN EXCAVATIONS WHOSE DIMENSIONS CAUSE THEM TO BE CONSIDERED TRENCHES BY OSHA, REGARDLESS OF WHETHER FOR THE INSTALLATION OF UTILITIES, FOUNDATIONS OR ANY OTHER SITE ELEMENT, IS EQUAL TO OR GREATER THAN 5.00' DEPTH, THEN THE CONTRACTOR SHALL NOT PERFORM ANY TRENCHING ON THIS SITE UNTIL HE HAS FIRST OBTAINED DETAILED PLANS AND SPECIFICATIONS FOR TRENCH SAFETY SYSTEMS CONFORMING TO OSHA REQUIREMENTS. SUCH PLANS AND SPECIFICATIONS SHALL BE PREPARED BY A REGISTERED PROFESSIONAL ENGINEER EMPLOYED BY OR CONTRACTED BY THE CONTRACTOR AND SHALL BE CONSIDERED A PART OF THE CONTRACTOR'S MEANS AND METHOD'S OF CONSTRUCTION. IF THIS PROJECT IS OFFERED FOR BID, THE BIDS MUST CONTAIN A SEPARATE UNIT PRICE PAY ITEM FOR TRENCH SAFETY. 8. WATER MAIN MATERIALS SHALL BE IN ACCORDANCE WITH TOWN OF WESTLAKE STANDARD WATER SYSTEM DESIGN REQUIREMENTS. CLASS 200. 9. SANITARY SEWER LINE MATERIAL SHALL BE IN ACCORDANCE WITH TOWN OF WESTLAKE STANDARD SANITARY SEWER DESIGN REQUIREMENTS. 10. ANY WATER OR SANITARY SEWER SERVICE LOCATED OUTSIDE OF A STREET, ALLEY OR EASEMENT SHALL BE INSTALLED BY A PLUMBER AND BE INSPECTED BY CODE ENFORCEMENT. 11. BLUE EMS DISKS SHALL BE PLACED ON THE WATER LINE AT EVERY CHANGE IN DIRECTION, VALVES AND SERVICES. GREEN EMS DISKS SHALL BE PLACED ON THE SEWER LINE AT EVERY MANHOLE, CLEANOUT AND SERVICE. C5.0UTILITY PLANGRAPHIC SCALE 0 1 INCH = 30 FEET 303015 DOMESTIC 1" 1"IRRIGATION SIZE REMARKTYPEID EXISTING L E G E N D EXISTING WATER MAIN EXISTING SANITARY SEWER EXISTING SEWER MANHOLE EXISTING FIRE HYDRANT EXISTING WATER METER EXISTING OVERHEAD ELECTRIC EXISTING ELECTRIC VAULT EXISTING FIBER OPTIC MARKER EXISTING POWER POLE EXISTING STORM SEWER EXISTING TOWN OF WESTLAKE GPS MONUMENT NO. 5 THE STATION IS A TOP SECURITY ROD MONUMENT WITH 3-1/4" ALUMINUM CAP STAMPED "TOWN OF WESTLAKE GPS 5" SET IN WELL WITH AN ALUMINUM ACCESS COVER SET FLUSH WITH GROUND. NORTHING: 7043290.79 EASTING: 2355747.51 ELEVATION: 662.20 THESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.comCAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSResolution 18-13 DENTON HIGHWAY(U.S. HIGHWAY 377)( VARIABLE WIDTH RIGHT-OF-WAY )N 71°1 8 ' 3 4 " W 1 9 8 . 9 7 ' S 71°1 8 ' 3 4 " E 3 3 8 . 1 8 ' N 71°1 8 ' 3 4 " W 52.00'L1L2(BASIS OF BEARINGS)N 24°25'10" E 251.25'N 71° 1 8 ' 3 4 " W 119.27 'CV1TEXAS AND PACIFIC RAILROAD( 100' RIGHT-OF-WAY )LEGEND TOP OF PAVEMENT ELEVATION TOP OF CURB ELEVATION GUTTER ELEVATION EXISTING SPOT ELEVATION EXISTING CONTOURS PROPOSED CONTOURS GRADING GENERAL NOTES 1. REFER TO GEO-TECHNICHAL ENGINEERING REPORT NO. W180133 BY ALPHA TESTING, INC. ON FEBRUARY 14, 2018 FOR SITE WORK. 2. TRENCH SAFETY: IF ANY TRENCH ON THIS JOB SITE, INCLUDING OPEN EXCAVATIONS WHOSE DIMENSIONS CAUSE THEM TO BE CONSIDERED TRENCHES BY O.S.H.A REGARDLESS OF WHETHER FOR THE INSTALLATION OF UTILITIES, FOUNDATIONS OR ANY OTHER SITE ELEMENT, IS EQUAL TO OR GREATER THAN 5.00' DEPTH, THEN THE CONTRACTOR SHALL NOT PERFORM ANY TRENCHING ON THIS SITE UNTIL HE HAS FIRST OBTAINED DETAILED PLANS AND SPECIFICATIONS FOR TRENCH SAFETY SYSTEMS CONFORMING TO O.S.H.A. REQUIREMENTS. SUCH PLANS AND SPECIFICATIONS SHALL BE PREPARED BY A REGISTERED PROFESSIONAL ENGINEER EMPLOYED BY OR CONTRACTED BY THE CONTRACTOR AND SHALL BE CONSIDERED A PART OF THE CONTRACTOR'S MEANS AND METHOD'S OF CONSTRUCTION. IF THIS PROJECT IS OFFERED FOR BID, THE BIDS MUST CONTAIN A SEPARATE UNIT PRICE PAY ITEM FOR TRENCH SAFETY. 3. ALL SURPLUS EXCAVATION AND WASTE MATERIAL SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND IT SHALL BE HIS SOLE RESPONSIBILITY TO REMOVE SUCH SURPLUS EXCAVATION AND WASTE MATERIAL FROM THE SITE TO A PUBLIC DUMP SITE APPROVED FOR THE DISPOSAL OF SUCH MATERIALS. IF SURPLUS EXCAVATION IS REMOVED FROM THIS SITE TO ANOTHER PROPERTY, IT SHALL BE PLACED ON SUCH PROPERTY WITH THE WRITTEN CONSENT OF THE OWNER(S) OF SUCH PROPERTY. A COPY OF SUCH WRITTEN CONSENT SHALL BE PROVIDED TO THE OWNER. IF THE CONTRACTOR WISHES TO DISPOSE OF SURPLUS EXCAVATION ON-SITE, IT SHALL BE ONLY WITH THE PRIOR APPROVAL OF THE OWNERS PROJECT REPRESENTATIVE AND CARE SHOULD BE TAKEN TO AVOID BLOCKING NATURAL DRAINAGE AND INCREASING STEEP SLOPES. 4. THE CONTRACTOR IS REQUIRED TO PROVIDE HIS OWN STAKING AND TO VERIFY PROJECT ELEVATIONS. "MATCH EXISTING" SHALL BE UNDERSTOOD TO APPLY TO BOTH VERTICAL ELEVATION AND HORIZONTAL ALIGNMENT. 5. ANY EXISTING SITE IMPROVEMENTS OR UTILITIES REMOVED, DAMAGED OR UNDERCUT BY THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED OR REPLACED AS DIRECTED BY THE OWNER'S REPRESENTATIVE AND AS APPROVED BY THE OWNER OF SUCH UTILITY. ANY SUCH REPAIR OR REPLACEMENT SHALL BE AT THE CONTRACTOR'S SOLE EXPENSE. 6. THE CONTRACTOR SHALL PREPARE ALL LANDSCAPE AREAS INCLUDING STREET RIGHT-OF-WAY AREAS TO AN ACCEPTABLE SUB-GRADE CONDITION IN ACCORDANCE WITH THE LANDSCAPE PLANS. IF THE CONTRACTOR IS NOT EMPLOYED TO PROVIDE AND INSTALL LANDSCAPING, HE SHALL PREPARE A FINISHED AND COMPACTED SUB-GRADE IN THE LANDSCAPING AREAS 4" BELOW NOMINAL FINISH GRADE AS SHOWN ON THE PLANS AND SHALL ADD 2" OF TOPSOIL TO BRING LANDSCAPING SUB-GRADE AS PROVIDED TO THE LANDSCAPING CONTRACTOR, TO 2" BELOW NOMINAL FINISH GRADE. 7. THE CONTRACTOR SHALL STOCKPILE AN ADEQUATE QUANTITY OF TOPSOIL, FOR USE BY THE LANDSCAPER TO BRING FINISH GRADE IN THE LANDSCAPED AREAS TO NOMINAL FINISH GRADE AS SHOWN ON THESE PLANS. WHERE SOD IS PLACED, ADJUST GRADES SO THAT TOP OF SOD MATCHES TOP OF CURB AND FLOW LINES OF DRAINAGE SWALES, UNLESS OTHERWISE SPECIFIED ON THESE PLANS. C6.0GRADING PLAN1 INCH = 30 FEET GRAPHIC SCALE 0 303015 NOTE PUBLIC RIGHT OF WAY, EASEMENTS AND COMMON AREAS MUST BE STABILIZED WITH PERENNIAL VEGETATION COVER, FULLY ESTABLISHED WITH 100% COVERAGE, OR OTHER APPROVED STABILIZATION METHOD. THESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.comCAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSTOWN OF WESTLAKE GPS MONUMENT NO. 5 THE STATION IS A TOP SECURITY ROD MONUMENT WITH 3-1/4" ALUMINUM CAP STAMPED "TOWN OF WESTLAKE GPS 5" SET IN WELL WITH AN ALUMINUM ACCESS COVER SET FLUSH WITH GROUND. NORTHING: 7043290.79 EASTING: 2355747.51 ELEVATION: 662.20 Resolution 18-13 5 6 6 6 2 8 10' B. L .DENTON HIGHWAY(U.S. HIGHWAY 377)( VARIABLE WIDTH RIGHT-OF-WAY )N 71° 1 8 ' 3 4 " W 1 9 8 . 9 7 'N 24°25'10" E 125.62'S 71°1 8 ' 3 4 " E 3 3 8 . 1 8 ' N 71° 1 8 ' 3 4 " W 52.00'L1L230' B.L.50' B.L.LOT 2, B L O C K 1 46,020 S Q . F T . / 1 . 0 5 6 A C . LOT 1, B L O C K 1 WEST L A K E C O R N E R S N O R T H COUN T Y C L E R K ' S F I L E N O . D2110 3 4 1 8 5 , R . P . R . T . C . T . HILL W O O D A L L I A N C E RESI D E N T I A L , L . P . , a Texa s l i m i t e d p a r t n e r s h i p COUN T Y C L E R K ' S F I L E N O . D2051 7 9 1 0 8 , R . P . R . T . C . T . HW 2 4 2 1 L A N D , L . P . , a Texa s l i m i t e d p a r t n e r s h i p COUN T Y C L E R K ' S F I L E N O . D2091 8 1 3 3 6 , R . P . R . T . C . T . FIRE L A N E FIRE L A N E FIRE LANEFIRE LANEFIRE LANEFIRE LANEFIRE LAN E FIRE LANE FF=664.74(BASIS OF BEARINGS)N 24°25'10" E 125.63'N 71° 1 8 ' 3 4 " W 119.2 7 ' S 71°1 8 ' 3 4 " E 3 5 5 . 5 9 'CV17 12 EXISTI N G STOR E 7,500 S . F . PROP O S E D ADDITI O N 4,800 S . F . 6 3 7 6 6 6TEXAS AND PACIFIC RAILROAD( 100' RIGHT-OF-WAY )VOLUME NOTES: 1. ALL CUT AND FILL NUMBERS ARE UNADJUSTED - NO SHRINK OR BULK FACTOR. 2. ALL CUT AND FILL NUMBERS ARE TO SUBGRADE BASED ON THESE ASSUMPTIONS: ·THE SUBGRADE BELOW THE BUILDING IS ASSUMED TO BE 6" BELOW FINISHED FLOOR. ·IT IS ASSUMED PAVED AREAS ARE 12" ABOVE SUBGRADE AND SIDEWALK AREAS ARE 4" ABOVE SUBGRADE. 3. NO CALCULATIONS HAVE BEEN MADE FOR STRUCTURAL FILL WITHIN BUILDINGS. 4. NO ADJUSTMENTS HAVE BEEN MADE FOR STRIPPING AWAY TOPSOIL. 5. EXISTING TOPOGRAPHY MAY DIFFER FROM WHAT IS SHOWN ON THIS DRAWING. 6. DUE TO VARYING METHODS AND SOFTWARE, THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING EARTHWORK VOLUMES. GRADING VOLUME TABLE CUT YD³ FILL YD³ NET YD³ 908 619 288 TOTAL DISTURBED ACREAGE = 0.914 ACRES GRADING CUT FILL ANALYSIS1 INCH = 30 FEET GRAPHIC SCALE 0 1530 30 THESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.comCAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262BLOCK 1 LOT 2WESTLAKE CORNERS NORTHSPEC'S WINE & SPIRITSTOWN OF WESTLAKE GPS MONUMENT NO. 5 THE STATION IS A TOP SECURITY ROD MONUMENT WITH 3-1/4" ALUMINUM CAP STAMPED "TOWN OF WESTLAKE GPS 5" SET IN WELL WITH AN ALUMINUM ACCESS COVER SET FLUSH WITH GROUND. NORTHING: 7043290.79 EASTING: 2355747.51 ELEVATION: 662.20 C6.1 GRADING GENERAL NOTES 1. REFER TO GEO-TECHNICHAL ENGINEERING REPORT NO. --------- BY ---------------, INC. ON -------- -, 20-- FOR SITE WORK. 2. TRENCH SAFETY: IF ANY TRENCH ON THIS JOB SITE, INCLUDING OPEN EXCAVATIONS WHOSE DIMENSIONS CAUSE THEM TO BE CONSIDERED TRENCHES BY O.S.H.A REGARDLESS OF WHETHER FOR THE INSTALLATION OF UTILITIES, FOUNDATIONS OR ANY OTHER SITE ELEMENT, IS EQUAL TO OR GREATER THAN 5.00' DEPTH, THEN THE CONTRACTOR SHALL NOT PERFORM ANY TRENCHING ON THIS SITE UNTIL HE HAS FIRST OBTAINED DETAILED PLANS AND SPECIFICATIONS FOR TRENCH SAFETY SYSTEMS CONFORMING TO O.S.H.A. REQUIREMENTS. SUCH PLANS AND SPECIFICATIONS SHALL BE PREPARED BY A REGISTERED PROFESSIONAL ENGINEER EMPLOYED BY OR CONTRACTED BY THE CONTRACTOR AND SHALL BE CONSIDERED A PART OF THE CONTRACTOR'S MEANS AND METHOD'S OF CONSTRUCTION. IF THIS PROJECT IS OFFERED FOR BID, THE BIDS MUST CONTAIN A SEPARATE UNIT PRICE PAY ITEM FOR TRENCH SAFETY. 3. ALL SURPLUS EXCAVATION AND WASTE MATERIAL SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND IT SHALL BE HIS SOLE RESPONSIBILITY TO REMOVE SUCH SURPLUS EXCAVATION AND WASTE MATERIAL FROM THE SITE TO A PUBLIC DUMP SITE APPROVED FOR THE DISPOSAL OF SUCH MATERIALS. IF SURPLUS EXCAVATION IS REMOVED FROM THIS SITE TO ANOTHER PROPERTY, IT SHALL BE PLACED ON SUCH PROPERTY WITH THE WRITTEN CONSENT OF THE OWNER(S) OF SUCH PROPERTY. A COPY OF SUCH WRITTEN CONSENT SHALL BE PROVIDED TO THE OWNER. IF THE CONTRACTOR WISHES TO DISPOSE OF SURPLUS EXCAVATION ON-SITE, IT SHALL BE ONLY WITH THE PRIOR APPROVAL OF THE OWNERS PROJECT REPRESENTATIVE AND CARE SHOULD BE TAKEN TO AVOID BLOCKING NATURAL DRAINAGE AND INCREASING STEEP SLOPES. 4. THE CONTRACTOR IS REQUIRED TO PROVIDE HIS OWN STAKING AND TO VERIFY PROJECT ELEVATIONS. "MATCH EXISTING" SHALL BE UNDERSTOOD TO APPLY TO BOTH VERTICAL ELEVATION AND HORIZONTAL ALIGNMENT. 5. ANY EXISTING SITE IMPROVEMENTS OR UTILITIES REMOVED, DAMAGED OR UNDERCUT BY THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED OR REPLACED AS DIRECTED BY THE OWNER'S REPRESENTATIVE AND AS APPROVED BY THE OWNER OF SUCH UTILITY. ANY SUCH REPAIR OR REPLACEMENT SHALL BE AT THE CONTRACTOR'S SOLE EXPENSE. 6. THE CONTRACTOR SHALL PREPARE ALL LANDSCAPE AREAS INCLUDING STREET RIGHT-OF-WAY AREAS TO AN ACCEPTABLE SUB-GRADE CONDITION IN ACCORDANCE WITH THE LANDSCAPE PLANS. IF THE CONTRACTOR IS NOT EMPLOYED TO PROVIDE AND INSTALL LANDSCAPING, HE SHALL PREPARE A FINISHED AND COMPACTED SUB-GRADE IN THE LANDSCAPING AREAS 4" BELOW NOMINAL FINISH GRADE AS SHOWN ON THE PLANS AND SHALL ADD 2" OF TOPSOIL TO BRING LANDSCAPING SUB-GRADE AS PROVIDED TO THE LANDSCAPING CONTRACTOR, TO 2" BELOW NOMINAL FINISH GRADE. 7. THE CONTRACTOR SHALL STOCKPILE AN ADEQUATE QUANTITY OF TOPSOIL, FOR USE BY THE LANDSCAPER TO BRING FINISH GRADE IN THE LANDSCAPED AREAS TO NOMINAL FINISH GRADE AS SHOWN ON THESE PLANS. WHERE SOD IS PLACED, ADJUST GRADES SO THAT TOP OF SOD MATCHES TOP OF CURB AND FLOW LINES OF DRAINAGE SWALES, UNLESS OTHERWISE SPECIFIED ON THESE PLANS. Resolution 18-13 DENTON HIGHWAY(U.S. HIGHWAY 377)( VARIABLE WIDTH RIGHT-OF-WAY )N 71° 1 8 ' 3 4 " W 1 9 8 . 9 7 ' S 71°1 8 ' 3 4 " E 3 3 8 . 1 8 ' N 71° 1 8 ' 3 4 " W 52.00'L1L2(BASIS OF BEARINGS)N 24°25'10" E 251.25'N 71° 1 8 ' 3 4 " W 119.2 7 'CV1TEXAS AND PACIFIC RAILROAD( 100' RIGHT-OF-WAY )C7.12C7.1 5 3C7.1C7.14C7.1 4 C7.1 3 C7.1 2 C7.1 2 C7.14LEGEND PROPOSED EXPANSION JOINT PROPOSED PAVEMENT SAW CUT C7.0PAVING PLAN1 INCH = 30 FEET GRAPHIC SCALE 0 303015 PAVING NOTES 1. REFER TO GEO-TECHNICHAL ENGINEERING REPORT NO. W180133 BY ALPHA TESTING, INC. ON FEBRUARY 14, 2018 FOR SITE WORK. 2. ALL CONCRETE PAVEMENT TO BE AS FOLLOWS: SIDEWALK AREA 4" THICK CLASS "A" CONCRETE PAVEMENT 4000 P.S.I. #3 REBAR W/6" COMPACTED SUB-GRADE @ 18" O.C.E.W. PARKING AREA 5" THICK CLASS "C" CONCRETE PAVEMENT 3600 P.S.I. #3 REBAR W/5" COMPACTED SUB-GRADE @ 18" O.C.E.W. FIRE LANE 6" THICK CLASS "C" CONCRETE PAVEMENT 4000 P.S.I. #4 REBAR W/6" LIME SUB-GRADE @ 24" O.C.E.W. DUMPSTER PAD 7" THICK CLASS "C" CONCRETE PAVEMENT 4000 P.S.I. #4 REBAR W/6" LIME SUB-GRADE @ 18" O.C.E.W. 3. THE SUB-GRADE SHOULD BE SCARIFIED TO A MINIMUM DEPTH OF 6" AND UNIFORMLY COMPACTED TO A MINIMUM OF 95% OF STANDARD PROCTOR DENSITY (A.S.T.M. D 698), NEAR MINUS 1 TO PLUS 3 PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT DETERMINE BY THE TEST. 4. GEOTECHNICAL REPORT RECOMMEND THAT SUBGRADE STABILIZATION EXTEND TO AT LEAST ONE FOOT BEYOND PAVEMENT EDGES TO AID IN REDUCING PAVEMENT MOVEMENTS AND CRACKING ALONG THE CURB LINE DUE TO SEASONAL MOISTURE VARIATIONS AFTER CONSTRUCTION. 5. REINFORCED PORTLAND CEMENT CONCRETE PAVEMENT SHOULD CONSIST OF PORTLAND CEMENT CONCRETE HAVING A 28-DAY COMPRESSIVE STRENGTH AS STATED ABOVE. THE MIX SHOULD BE DESIGNED IN ACCORDANCE WITH THE A.C.I. CODE 318 USING 3 TO 6 PERCENT AIR ENTRAINMENT. 6. ALL REINFORCEMENT SHALL BE MINIMUM GRADE 60 IN ACCORDANCE WITH A.S.T.M. A-615. PLACE ALL REINFORCING BARS ON PLASTIC CHAIRS TO POSITION THE STEEL AT APPROXIMATELY MID POINT IN THE SLAB. OTHER TYPES OF SUPPORT (ROCKS, BRICKS, ETC.) ARE NOT ALLOWED. 7. SAWED CONTROL JOINTS SHALL BE PLACED AT 15' MAX. SPACING OR AS SHOWN ON THE PLAN. CONTROL JOINTS SHALL BE SAWED WITHIN 3 HOURS AFTER PLACING CONCRETE. JOINTS SHALL BE PROPERLY CLEANED AND SEALED AS SOON AS POSSIBLE AFTER JOINTS ARE CUT. 8. EXPANSION JOINT SPACING TO BE A MAXIMUM OF 60 FEET. CONTROL JOINTS FORMED BY SAWING ARE RECOMMENDED EVERY 12 TO 15 FEET IN BOTH LONGITUDINAL AND TRANSVERSE DIRECTION. 9. ALL PAVEMENTS, SIDEWALKS AND AREA PAVEMENTS SHALL HAVE A MEDIUM BROOM FINISH. 10. THE CONTRACTOR IS REQUIRED TO PROVIDE HIS OWN STAKING AND TO VERIFY PROJECT ELEVATIONS. "MATCH EXISTING" SHALL BE UNDERSTOOD TO APPLY TO BOTH VERTICAL ELEVATION AND HORIZONTAL ALIGNMENT. 11. ANY EXISTING SITE IMPROVEMENTS OR UTILITIES REMOVED, DAMAGED OR UNDERCUT BY THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED OR REPLACED AS DIRECTED BY THE OWNER'S REPRESENTATIVE AND AS APPROVED BY THE OWNER OF SUCH UTILITY. ANY SUCH REPAIR OR REPLACEMENT SHALL BE AT THE CONTRACTOR'S SOLE EXPENSE. 12. SIDEWALK AROUND THE BUILDING SHALL NOT BE STRUCTURALLY CONNECTED TO THE BUILDING FOUNDATION UNLESS IT IS NOTED ON THE STRUCTURAL PLANS. THESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.comCAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSResolution 18-13 C7.1PAVING DETAILSN.T.S. 3 ON-SITE EXPANSION JOINT DETAIL NOTES 1. 1/2" EXPANSION JOINTS SHALL BE SPACED AT 60' INTERVALS, OR AS OTHERWISE SPECIFIED. JOINTS SHALL BE REDWOOD WITH THREE (3) #3 SLIP DOWELS WITH END CAPS AT EQUAL SPACING. 2. TOOL GRADE EVERY 5' ON 5' WALKS AND EVERY 4' ON 4' WALKS. 3. SIDEWALKS SHALL BE CLASS "A" CONCRETE. 4. WHEN CONCRETE WALK IS ADJACENT TO EXISTING CONCRETE, DEPTH OF BITUMINOUS EXPANSION JOINT FILLER SHALL BE SUFFICIENT TO PREVENT CONCRETE TO CONCRETE CONTACT BETWEEN WALK AND CONCRETE. WHEN SIDEWALK IS LOCATED AT THE BACK OF CURB THE NO. 3 REBAR AT 18" O.C. FOR THE SIDEWALK SHOULD EXTEND TO A DEPTH OF APPROXIMATELY 3" INTO THE BACK OF THE CURB AND SHOULD BE ANCHORED IN PLACE WITH EPOXY RESIN. 5. SIDEWALK SUB-GRADE SHALL BE COMPACTED TO MINIMUM 95% STANDARD PROCTOR. 6. A MAXIMUM OF 1" OF SAND MAY BE USED FOR LEVEL UP ONLY. SIDE ELEVATIONSECTION N.T.S. 2 ON-SITE CURB AND GUTTER DETAIL N.T.S. 4 ON-SITE SAWCUT DETAILT PLAN N.T.S. 5 CONCRETE SIDEWALK DETAIL N.T.S. 1 C7.1 TYPICAL BOLLARD DETAILS NOTES 1. INSTALL CONCRETE FOOTING AND BOLLARD PRIOR TO PLACING 6" REINFORCED CONCRETE PAD; GENERAL CONTRACTOR RESPONSIBLE FOR BOLLARD LEVELING AND PLUMB. 2. PRIOR TO PAINTING, ALL GALVANIZED METAL MUST BE PRIMED; PAINT DARK BRONZE. C7.1 C7.1 C7.1C7.1 THESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.com16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSResolution 18-13 10' B. L .DENTON HIGHWAY(U.S. HIGHWAY 377)( VARIABLE WIDTH RIGHT-OF-WAY )N 71° 1 8 ' 3 4 " W 1 9 8 . 9 7 ' S 71°1 8 ' 3 4 " E 3 3 8 . 1 8 ' N 71° 1 8 ' 3 4 " W 52.00'L1L230' B.L.50' B.L.(BASIS OF BEARINGS)N 24°25'10" E 251.25'N 71° 1 8 ' 3 4 " W 119.2 7 'CV1TEXAS AND PACIFIC RAILROAD( 100' RIGHT-OF-WAY )CONSTRUCTION NOTES 1. MAXIMUM SLOPE OF CURB RAMP SHALL BE 1:12 (8.33%) - 5% RECOMMENDED. 2. MAXIMUM SLOPE OF THE CURB RAMP'S "FLARED SIDES" SHALL BE (8.33% MAX). 3. SLOPE AND CROSS-SLOPE OF A SIDEWALK LEADING INTO A CURB RAMP'S SYSTEM SHALL BE A MAXIMUM OF 1:50 (2%). 4. MAXIMUM SLOPE OF A HANDICAPPED ACCESSIBLE ROUTE ALONG A SIDEWALK LEADING INTO A CURB RAMP, BEFORE IT MUST BE CONSIDERED A RAMP IS 1:20 (5%). 5. ALL SLOPED SURFACES AT CURB RAMP SYSTEMS MUST HAVE A "SIGNIFICANT COLOR CONTRAST" FOR THE SEEING IMPAIRED. THEREFORE ALL SUCH SLOPES MUST HAVE "INTEGRAL COLOR IN CONCRETE" OR "STAINED" CONCRETE COMPARED TO THE ADJACENT "FLAT" SIDEWALK/PAVING SURFACE. 6. SLOPED CURB-RAMP SURFACE TO HAVE TEXTURE (IE.-FORMED/SAWCUT GROVES 3/4" WIDE X 1/4" DEEP @ 2" ON-CENTER FORMED PERPENDICULAR TO PATH OF TRAVEL FOR THE BLIND TO FEEL TEXTURE BENEATH THEIR FEET & FOR WHEELCHAIR TRACTION - ARRANGED SO WATER WILL NOT ACCUMULATE. 7. MAXIMUM SLOPE AND CROSS-SLOPE OF HANDICAPPED ACCESSIBLE PARKING SPACE & ADJACENT ACCESS AISLE IS 1:50 (2%) IN ANY DIRECTION. 8. ALL SIDEWALKS SHALL HAVE A 5% MAXIMUM LONGITUDINAL SLOPE WITH A 2% MAXIMUM CROSS SLOPE. 9. DETECTABLE WARNING SURFACE (DOMES TO RUN PARALLEL TO PEDESTRIAN TRAVEL). C8.0ADA PLANC8.0 1 BACKGROUND - WHITE HANDICAP SYMBOL - WHITE ON BLUE ON NUMBER OF REQUIRED SPACES. VERIFY SIGN REQUIREMENTS WITH CITY. LEGEND AND BORDER - GREEN USE SINGLE OR DOUBLE ARROW DEPENDING SIGN COLORS: HANDICAP SIGN NOTES PLAN 2 C8.0 HANDICAP CURB CUT DETAIL C8.0 3 1 INCH = 30 FEET GRAPHIC SCALE 0 303015 SECTION N.T.S. N.T.S. N.T.S. TYPICAL POLE MOUNTED HANDICAP SIGNAGE HANDICAPPED ACCESSIBLE CURB RAMP DETAIL (FRONT APPROACH) BARRIER FREE RAMP (BFR) THESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.com16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSResolution 18-13 DENTON HIGHWAYN 71° 1 8 ' 3 4 " W 1 9 8 . 9 7 ' S 71° 1 8 ' 3 4 " E 3 3 8 . 1 8 ' N 71° 1 8 ' 3 4 " W 52.00'L1L2(BASIS OF BEARINGS)N 24°25'10" E 251.25'N 71° 1 8 ' 3 4 " W 119.2 7 'CV1TEXAS AND PACIFIC RAILROAD( 100' RIGHT-OF-WAY )1.7 0.21B 3.3 0.40A 1.4 0.17C 2.3 2.80D 0.1 0.02E 2.3 0.72F 1.0 0.26G DENTON HIGHWAYN 71° 1 8 ' 3 4 " W 1 9 8 . 9 7 ' S 71° 1 8 ' 3 4 " E 3 3 8 . 1 8 ' N 71° 1 8 ' 3 4 " W 52.00'L1L2(BASIS OF BEARINGS)N 24°25'10" E 251.25'N 71° 1 8 ' 3 4 " W 119.2 7 'CV1TEXAS AND PACIFIC RAILROAD( 100' RIGHT-OF-WAY )3.3 1.40B 3.3 1.40A 3.3 1.40C 3.3 1.40D 0.9 0.11E 6.1 0.74F 1.2 0.15G EXISTING CONTOURS DRAINAGE DIVIDE FLOW DIRECTION ACREAGE A DRAINAGE LEGEND THESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.comCAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSC9.0DRAINAGE AREA MAP1 INCH = 30 FEET GRAPHIC SCALE 0 303015 AREA NO. Q-1001.08 9.7 Resolution 18-13 DENTON HIGHWAY(U.S. HIGHWAY 377)( VARIABLE WIDTH RIGHT-OF-WAY )N 71° 1 8 ' 3 4 " W 1 9 8 . 9 7 ' S 71°1 8 ' 3 4 " E 3 3 8 . 1 8 ' N 71° 1 8 ' 3 4 " W 52.00'L1L2(BASIS OF BEARINGS)N 24°25'10" E 251.25'N 71° 1 8 ' 3 4 " W 119.2 7 'CV1TEXAS AND PACIFIC RAILROAD( 100' RIGHT-OF-WAY )XXXXXXXXXXXX X X X X X X X X X X X X X X X X XXXXXXXXXX X C10.0EROSION CONTROL PLAN1 INCH = 30 FEET GRAPHIC SCALE 0 303015 EROSION GENERAL NOTES 1. EROSION CONTROL DEVICES AS SHOWN ON THE EROSION CONTROL PLAN FOR THE PROJECT SHALL BE INSTALLED PRIOR TO THE START OF LAND DISTURBING ACTIVITIES ON THE PROJECT. 2. ALL EROSION CONTROL DEVICES ARE TO BE INSTALLED IN ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS FOR THE PROJECT. CHANGES ARE TO BE APPROVED BEFORE CONSTRUCTION BY THE DESIGN ENGINEER FOR THE TOWN OF WESTLAKE. 3. IF THE EROSION CONTROL PLANS AS APPROVED CANNOT CONTROL EROSION AND OFF-SITE SEDIMENTATION FROM THE PROJECT, THE EROSION CONTROL PLAN WILL BE REQUIRED TO BE REVISED AND/OR ADDITIONAL EROSION CONTROL DEVICES WILL BE REQUIRED ON SITE. 4. IF OFF-SITE SOIL BORROW OR SPOIL SITES ARE USED IN CONJUNCTION WITH THIS PROJECT, THIS INFORMATION SHALL BE DISCLOSED AND SHOWN ON THE EROSION CONTROL PLAN. OFF-SITE BORROW AND SPOIL AREAS ARE CONSIDERED A PART OF THE PROJECT SITE AND THEREFORE SHALL COMPLY WITH THE TOWN OF WESTLAKE EROSION CONTROL REQUIREMENTS. THESE AREAS SHALL BE STABILIZED WITH PERMANENT GROUND COVER PRIOR TO FINAL APPROVAL OF THE PROJECT. 5. ALL EROSION CONTROL DEVICES SHALL BE INSPECTED WEEKLY BY THE CONTRACTOR AND AFTER ALL MAJOR RAIN EVENTS. 6. ALL NON-IMPERVIOUS AREAS AFTER CONSTRUCTION SHALL BE COVERED WITH SOD OR LANDSCAPED IN ACCORDANCE WITH THE LANDSCAPE DRAWINGS. ALL OTHER REMAINING AREAS SHALL BE HYDRO-MULCHED OR COVERED WITH CURLEX BLANKET (WHERE SHOWN) AND MAINTAINED UNTIL ESTABLISHED. 7. TEMPORARY STONE STABILIZED CONSTRUCTION ENTRANCE SHALL HAVE THE FOLLOWING MINIMUM DIMENSIONS: 25' WIDE X 50' LONG X 6" DEEP. (3"-5" COURSE AGGREGATE). PLACE FILTER FABRIC UNDER STONE PER N.C.T.C.O.G. ITEM 2.23.3. 8. THE STABILIZED CONSTRUCTION ENTRANCE IS TO BE USED AS A VEHICLE WASH DOWN AREA FOR DEBRIS AND SOIL REMOVAL PRIOR TO EXITING THE SITE. THIS STABLIZED ENTRANCE SHALL BE TOP DRESSED WITH ADDITIONAL STONE AS NECESSARY. LOCATION OF STABLIZED ENTRANCE MAY BE MODIFIED IF APPROVED BY THE TOWN OF WESTLAKE AND THE DESIGN ENGINEER. 9. THE CONTRACTOR SHALL BE RESPONSIBLE, AS THE ENTITY EXERCISING OPERATIONAL CONTROL, FOR ALL PERMITTING AS REQUIRED BY THE EPA/TCEQ. THIS INCLUDES, BUT IS NOT LIMITED TO, PREPARATION OF N.O.I. AND NOT AND PAYMENT OF ALL ASSOCIATED FEES. 10.INSPECTIONS SHALL BE MADE WEEKLY AND AFTER RAIN STORM EVENTS TO INSURE THAT THE DEVICES ARE FUNCTIONING PROPERLY. WHEN SEDIMENT OR MUD HAS CLOGGED THE VOID SPACES BETWEEN STONES OR MUD IS BEING TRACKED ONTO A PUBLIC ROADWAY THE AGGREGATE PAD MUST BE WASHED DOWN OR REPLACED. RUNOFF FROM THE WASH DOWN OPERATION SHALL NOT BE ALLOWED TO DRAIN DIRECTLY OFF SITE WITHOUT FIRST FLOWING THROUGH ANOTHER BMP TO CONTROL OFF SITE SEDIMENTATION. PERIODIC RE-GRADING OR THE ADDITION OF NEW STONE MAY BE REQUIRED TO MAINTAIN THE EFFICIENCY OF THE INSTALLATION. 11.CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTAL OF N.O.I., N.O.T. & ANY ADDITIONAL INFORMATION REQUIRED BY THE E.P.A.. CONTRACTOR SHALL COMPLY WITH ALL E.P.A. STORM WATER POLLUTION PREVENTION REQUIREMENTS. 12.EROSION CONTROL MEASURES MAY ONLY BE PLACED IN FRONT OF INLETS, OR IN CHANNELS, DRAINAGEWAYS OR BORROW DITCHES AT RISK OF THE CONTRACTOR. THE CONTRACTOR SHALL REMAIN LIABLE FOR ANY DAMAGE CAUSED BY THE MEASURES, INCLUDING FLOODING DAMAGE, WHICH MAY OCCUR DUE TO BLOCKED DRAINAGE. AT THE CONCLUSION OF ANY PROJECT, ALL CHANNELS, DRAINAGEWAYS AND BORROW DITCHES IN THE WORK ZONE SHALL BE DREDGED OF ANY SEDIMENT GENERATED BY THE PROJECT OR DEPOSITED AS A RESULT OF EROSION CONTROL MEASURES. X L E G E N D SILT FENCE CONSTRUCTION ENTRANCE INLET PROTECTION THESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.comCAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSResolution 18-13 C11.0EROSION CONTROL DETAILSTHESE PLANS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND ARE PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. THEY MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DIMENSION GROUP. SHEETNo. DATEREVISION DESCRIPTIONproject no.:drawn:approved:date:ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING10755 SANDHILL ROAD, DALLAS, TEXAS 75238TEL: 214-343-9400 www.dimensiongrp.comCAUTION NOTICE TO CONTRACTORS THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND / OR ELEVATION OF THE EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUSUTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD.THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THECONTRACTOR MUCH CALL 811 AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THERESPONSIBILITY OF THE CONTRACTOR TO RELOCATED ALL EXISTING UTILITIESWHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.R16-70302/12/182341 U.S. 377TOWN OF WESLAKE, TEXAS 76262LOT 2R, BLOCK 1WESTCOAST HIGHWAY FIREBRAND ADDITIONSPEC'S WINE & SPIRITSGENERAL NOTES STABILIZED CONSTRUCTION ENTRANCE PROFILE VIEW PLAN VIEW GENERAL NOTES INLET PROTECTIONISOMETRIC PLAN VIEW INLET PROTECTION TYPICAL CONSTRUCTION ENTRANCE DETAILS1 C11.0 N.T.S.TYPICAL SILT FENCE DETAIL2 N.T.S. TYPICAL INLET PROTECTION DETAILS3 N.T.S. 6" MIN. SILT FENCE ISOMETRIC PLAN VIEW R.O.W. LENGTH AS SHOWN ON PLAN LENGTH AS SHOWN ON PLAN C11.0 C11.0 Resolution 18-13 Resolution 18-13 Resolution 18-13 Resolution 18-13 Resolution 18-13 NORTH ELEVATION T.O. CORNICE 128'-0" SPEC'S WINE SPIRITS T.O. ROOFING 122'-8" T.O. PARAPET 125'-8" T.O. WATERTABLE 104'-4" T.O. STOREFRONT 110'-0" T.O. EIFS 115'-0" T.O. SLAB 100'-0" T.O. SLAB 100'-0" T.O. CORNICE 125'-8" T.O. WALL 122'-0" 10 3 6 8 11 1 2 11 5 55 2 2 D 101 3 A4.3 5 D C 8 9 9 9 10 10 10 1010 13 11 13 14 14 14 147'-10"V.I.F4 1 A4.3 3 A4.2 1 A4.2 2 A4.1 3 A4.1 8 S1 B1 S2 E1 S1 E1 M1 B1B2 S1S2 S1S2 B1B2 W1 EAST ELEVATION T.O. PARAPET 127'-0" SPEC'S WINE SPIRITS EXISTING NEW T.O. CORNICE 128'-0" T.O. SLAB 100'-0" T.O. STOREFRONT 110'-0" T.O. SLAB 100'-0" T.O. ROOFING 122'-8" (EXISTING) 12 4 2 10 8 3 11 6 10 B 102 D D 9 14 7'-10"V.I.F3 A4.3 1 A4.3 12 8 E1 S1 W1 M1B1 S1 B2 EXTERIOR FINISH SCHEDULE S1 FIELD STONE, MATCH WITH EXISTING S2 STONE WAINSCOT SILL, MATCH WITH EXISTING B1 ARCHITECTURAL CONCRETE MASONRY,SPEC-BRIK COLOR, MATCH WITH EXISTING B2 ARCHITECTURAL CONCRETE MASONRY, MATCH WITH EXISTING E1 EIFS SYSTEM, BUILDING ACCENT TRIM AND PARAPET SHAPES, COLOR : SANDLEWOOD BEIGE SANDBLAST FINISH ,MATCH WITH EXISTING M1 METAL STANDING SEAM AWNING, MATCH WITH EXISTING W1 ALUMINUM STOREFRONT SYSTEM, MATCH WITH EXISTING ELDORADO STONE ELDORADO STONE PALESTINE CONCRETE TILE PALESTINE CONCRETE TILE DRYVIT SYSTEMS CUSTOM FABRICATIONS VISTA WALLS, DARK BRONZE PROJECT NUMBER: DATE: REVISIONS: 16-703 03-01-2018 2/28/2018 10755 SANDHILL ROAD | DALLAS, TEXAS 75238 | O: 214-343-9400 | F: 214-341-9060 | dimensiongrp.comARCHITECTURE ● CIVIL ENGINEERING ● MEP ENGINEERING ● PLANNINGSPECS2341 US 377WESTLAKE, TEXASA2.0 EXTERIOR ELEVATIONS 1EXTERIOR ELEVATION 1/4"=1'-0" 2EXTERIOR ELEVATION 1/4"=1'-0" KEYED NOTES DOOR AS SCHEDULED. GLAZING AS SCHEDULED SIGNAGE PROVIDED AND INSTALLED BY OTHERS UNDER SEPARATE PERMIT. G.C TO COORDINATE BLOCKING AND POWER REQUIREMENTS. NEW METAL STANDING SEAM AWNING MATCH WITH EXISTING DOWNSPOUT & SCUPPER WITH OVERFLOW ; MATCH EXISTING NEW EIFS CORNICE NOT USED EXTERIOR LIGHTING PROVIDED AND INSTALLED BY G.C.; RE: ELECTRICAL CONCRETE MASONRY MATCH WITH EXISTING FIELD STONE MATCH WITH EXISTING EIFS TRIM AND PARAPET SHAPES MATCH WITH EXISTING PATCH AND REPAIR WALLS WHERE EXISTING SIGNAGE IS REMOVED.MATCH EXISTING WALL COLOR AND EXISTING MORTAR COLOR NEW EXTERIOR AND FINISH SYSTEM MATCH WITH EXISTING STONE WAINSCOT WATERTABLE MATCH WITH EXISTING 1 2 3 4 5 6 7 8 9 10 11 12 13 14 GENERAL NOTES 1.ALL EXTERIOR MATERIALS TO MATCH EXISTING SPEC Resolution 18-13 WEST ELEVATION T.O. SLAB 100'-0" T.O. PARAPET 125'-8" EXISTINGNEW T.O. EIFS 115'-0" T.O. WALL 122'-0" 6 6 10 11 14 14 10 13 15 9 10 10 3 A4.1 8'-0"SIM S1 S1 S2B1B2 SOUTH ELEVATION T.O. SLAB 100'-0" T.O. PARAPET 127'-0"(EXISTING) T.O. STOREFRONT 110'-0"(EXISTING) 2 A 3 12 W1 EXTERIOR FINISH SCHEDULE S1 FIELD STONE, MATCH WITH EXISTING S2 STONE WAINSCOT SILL, MATCH WITH EXISTING B1 ARCHITECTURAL CONCRETE MASONRY,SPEC-BRIK COLOR, MATCH WITH EXISTING B2 ARCHITECTURAL CONCRETE MASONRY, MATCH WITH EXISTING E1 EIFS SYSTEM, BUILDING ACCENT TRIM AND PARAPET SHAPES, COLOR : SANDLEWOOD BEIGE SANDBLAST FINISH ,MATCH WITH EXISTING M1 METAL STANDING SEAM AWNING, MATCH WITH EXISTING W1 ALUMINUM STOREFRONT SYSTEM, MATCH WITH EXISTING ELDORADO STONE ELDORADO STONE PALESTINE CONCRETE TILE PALESTINE CONCRETE TILE DRYVIT SYSTEMS CUSTOM FABRICATIONS VISTA WALLS, DARK BRONZE PROJECT NUMBER: DATE: REVISIONS: 16-703 03-01-2018 2/28/2018 10755 SANDHILL ROAD | DALLAS, TEXAS 75238 | O: 214-343-9400 | F: 214-341-9060 | dimensiongrp.comARCHITECTURE ● CIVIL ENGINEERING ● MEP ENGINEERING ● PLANNINGSPECS2341 US 377WESTLAKE, TEXASA2.1 EXTERIOR ELEVATIONS 1EXTERIOR ELEVATION 1/4"=1'-0" 2EXTERIOR ELEVATION 1/4"=1'-0" KEYED NOTES DOOR AS SCHEDULED. GLAZING AS SCHEDULED; RE: WINDOW SCHEDULE SIGNAGE PROVIDED AND INSTALLED BY OTHERS UNDER SEPARATE PERMIT. G.C TO COORDINATE BLOCKING AND POWER REQUIREMENTS. NEW METAL STANDING SEAM AWNING MATCH WITH EXISTING DOWNSPOUT AND SCUPPER WITH OVERFLOW; MATCH EXISTING EIFS TRIM AND PARAPET SHAPES MATCH WITH EXISTING NOT USED EXTERIOR LIGHTING PROVIDED AND INSTALLED BY G.C.; RE: ELECTRICAL CONCRETE MASONRY MATCH WITH EXISTING NEW FIELD STONE MATCH WITH EXISTING NEW ROLL UP DOOR, RE: DOOR SCHEDULE PATCH AND REPAIR WALLS WHERE EXISTING SIGNAGE IS REMOVED.MATCH EXISTING WALL COLOR AND EXISTING MORTAR COLOR EXISTING ELECTRICAL AND CONDUIT TO BE PAINTED TO MATCH THE BUILDING STONE WAINSCOT SILL MATCH WITH EXISTING NEW EXTERIOR AND FINISH SYSTEM MATCH WITH EXISTING 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 GENERAL NOTES 1.ALL EXTERIOR MATERIALS TO MATCH EXISTING SPEC Resolution 18-13 T.O. SLAB0' -0"T.O. PARAPET.27' -0"NEWEXISTINGT.O. ROOFING22' -8"T.O. CORNICE.28' -0"STOREFRONT10' -0"T.O. SLAB0' -0"STOREFRONT.10' -0"T.O.WALL22' -0"T.O. PARAPET25' -8"WATERTABLE4' -4"T.O. EIFS15' -0"T.O. CORNICE25' -8"T.O. ROOFING22' -8"T.O. CORNICE.28' -0"T.O. SLAB0' -0"T.O. PARAPET.27' -0"STOREFRONT10' -0"T.O. SLAB0' -0"T.O.WALL22' -0"T.O. PARAPET25' -8"NEWEXISTINGT.O. EIFS15' -0"MASONRY: ARCHITECTURAL CONCRETE MASONRY "SPEC BRICK"COLOR A1 -TERRACOTA / RED / BLACK BLENDPALESTINE CONCRETE TILE CO.MORTAR: TEXAS WHEATMASONRY: ARCHITECTURAL CONCRETE MASONRY "SPEC BRICK"COLOR A4 -BUFF / TAN BLENDPALESTINE CONCRETE TILE CO.MORTAR: TEXAS WHEATEXTERIOR INSULATION & FINISH SYSTEM: BUILDING ACCENT TRIM& PARAPET SHAPES. COLOR #108 MANOR WHITE SANDBLAST FINISHDRYBIT SYSTEMS, INC.EXTERIOR INSULATION & FINISH SYSTEM: BUILDING ACCENT TRIM& PARAPET SHAPES. COLOR SANDALWOOD BEIGE SANDBLAST FINISHDRYBIT SYSTEMS, INC.METAL STANDING SEAM AWNING COLOR: PRE-WHEATHERED GALVALUMECUSTOM FABRICATION / BERRIDGEPAINT AT EXTERIOR DOORS, FRAMES, STEEL AWNING FRAMESAND DOWNSPOUTSCOLOR: TO MATCH W1BENJAMIN MOORE DARK BRONZESTONE WAINSCOT SILL: ELDORADO SILL PROFILE. COLOR BUCKSKIN.USE FULL 90 AND 135 DEGREE SHAPES AT ALL OTSIDE CORNERS.2 1/2" H X 19 3/4" L X 3" WELDORADO STONE HEADWATERS CONSTRUCTION MATERIALSFIELD STONE: VINEYARD TRAIL ROUGHCUT WITH FULL JOINT MORTAR TECHNIQUE.MORTAR: TEXAS WHEATELDORADO STONE HEADWATERS CONSTRUCTION MATERIALSALUM. STOREFRONT SYSTEM: VISTAWALL MOR: 2 1/4" X 4 1/2".COLOR: T.B.D. W/ 1" INSULATED GLASS VISTA WALL DARK BRONZE10755 SANDHILL ROAD, DALLAS, TEXAS 75238 TEL. 214-343-9400 FAX. 214-341-90603/12/2018 8:16:41 AMSPECS2341 US 377WESTLAKE, TEXASPRESPROJECT NUMBER 16-703EXTERIORELEVATIONS1/16" = 1'-0"1East1/16" = 1'-0"2North1/16" = 1'-0"3South1/16" = 1'-0"4WestResolution 18-13 Revisions © 2017 State Sign Job Name: THIS DRAWING IS THE EXCLUSIVE PROPERTY OF STATE SIGN. ANY USE OR REPRODUCTION OF THIS DRAWING WITHOUT WRITTEN AUTHORIZATION FROM STATE SIGN IS STRICTLY PROHIBITED. OWNERSHIP AND COPYRIGHT IS RETAINED IN ACCORDANCE WITH U.S. AND INTERNATIONAL TRADEMARK / COPYRIGHT LAWS. CORPORATE OFFICE 7630 HANSEN RD., HOUSTON, TX 77061 P: 713.943.1831 F: 713.943.9771 Proposal Drawing Final Drawing Client: Spec’s Liquor Location: 2341 Hwy 377 S., Westlake, TX 26232 Salesperson: Rani Huffaker Prj. Mngr.: Candy White Date: 1/26/18 Designer: File Name: 38346 R1 Spec's Westlake.cdr Proposal #: 38346 Job #: n/a Note: Page 1 of 1 Led Illuminated Channel Logo Qty: One (1) Scale: 1/4" = 1'-0" A/R1 Proposed • North Elevation • Scale: 1/8" = 1'-0" 77 SF 26'-0"27'-0"BEHIND FASCIAWALL 5" SERVICE PROVIDED BY OTHERS 12V REMOTE L.E.D. POWER SUPPLY IN GALVANIZED BOX NON-FERROUS FASTENERS []USE APPROPRIATE FOR WALL TYPE ¼" WEEP HOLE w/ LIGHT SCREEN [PREVENTS LIGHT LEAKS] ELECTRICAL SERVICE PENETRATIONS THRU-WALL WEATHERPROOFED w/ ⁄” WALL BUSTER PRE-FINISHED WHITE ALUMINUM BACKING L.E.D. MODULES .040” ALUMINUM RETURNS 1 ½” RETAINERS ⁄” ACRYLIC FACES L.E.D. ILLUMINATED CHANNEL LOGO SECTION SAFE FOR USE IN WET CLIMATE CONDITIONSSECTION • Scale: 1 ½" = 1'-0"9'-2"7'-0" 8'-4 ¾" Scope of Work: Manufacture and install one (1) internally illuminated channel logo as shown. • 3/16" #7328 White poly-carbonate face w/ 3M vinyl graphics. • .080" x 5" Alum. returns & .125" aluminum 1 ½" retainers [paint black] • .125” aluminum “wings” painted black w/ white vinyl “®” • GE TetraMAX White LED illumination. Resolution 18-13 Revisions © 2017 State Sign Job Name: THIS DRAWING IS THE EXCLUSIVE PROPERTY OF STATE SIGN. ANY USE OR REPRODUCTION OF THIS DRAWING WITHOUT WRITTEN AUTHORIZATION FROM STATE SIGN IS STRICTLY PROHIBITED. OWNERSHIP AND COPYRIGHT IS RETAINED IN ACCORDANCE WITH U.S. AND INTERNATIONAL TRADEMARK / COPYRIGHT LAWS. CORPORATE OFFICE 7630 HANSEN RD., HOUSTON, TX 77061 P: 713.943.1831 F: 713.943.9771 Proposal Drawing Final Drawing Client: Spec’s Liquor Location: 2341 Hwy 377 S., Westlake, TX 26232 Salesperson: Rani Huffaker Prj. Mngr.: Candy White Date: 1/26/18 Designer: File Name: 38346 Spec's Westlake.cdr Proposal #: 38346 Job #: n/a Note: Page 1 of 1 Led Illuminated Channel Letters Qty: One (1) Set Scale: 1/2" = 1'-0" A3'-0"8'-9 ½"7'-2 ½" 17'-0"1'-3"1'-3"Proposed • North Elevation • Scale: 1/8" = 1'-0" 51 SF 1'-0"Scope of Work: Manufacture and install one (1) set of internally illuminated LED channel letters. Specifications: • 3/16" #2397 Red acrylic faces • 1" Red tim-cap [to match the faces] • .040" returns [Dk Bronze] • Red GE TetraMAX LED illumination 26'-0"27'-0"BEHIND FASCIAWALL 5" SERVICE PROVIDED BY OTHERS 12V REMOTE L.E.D. POWER SUPPLY IN GALVANIZED BOX NON-FERROUS FASTENERS []USE APPROPRIATE FOR WALL TYPE ¼" WEEP HOLE w/ LIGHT SCREEN [PREVENTS LIGHT LEAKS] ELECTRICAL SERVICE PENETRATIONS THRU-WALL WEATHERPROOFED w/ ⁄” WALL BUSTER PRE-FINISHED WHITE ALUMINUM BACKING L.E.D. MODULES .040” ALUMINUM RETURNS 1” TRIM CAP ⁄” ACRYLIC FACES L.E.D. ILLUMINATED CHANNEL LETTER SECTION SAFE FOR USE IN WET CLIMATE CONDITIONSTYP. SECTION • Scale: 1 ½" = 1'-0" NOTE: THIS SET OF CHANNEL LETTERS IS THE EXACT SAME SIZE AND POSITION AS THE TWO EXISTING SETS ALREADY INSTALLED Resolution 18-13 Revisions © 2017 State Sign Job Name: THIS DRAWING IS THE EXCLUSIVE PROPERTY OF STATE SIGN. ANY USE OR REPRODUCTION OF THIS DRAWING WITHOUT WRITTEN AUTHORIZATION FROM STATE SIGN IS STRICTLY PROHIBITED. OWNERSHIP AND COPYRIGHT IS RETAINED IN ACCORDANCE WITH U.S. AND INTERNATIONAL TRADEMARK / COPYRIGHT LAWS. CORPORATE OFFICE 7630 HANSEN RD., HOUSTON, TX 77061 P: 713.943.1831 F: 713.943.9771 Proposal Drawing Final Drawing Client: Spec’s Liquor Location: 2341 Hwy 377 S., Westlake, TX 26232 Salesperson: Rani Huffaker Prj. Mngr.: Candy White Date: 1/26/18 Designer: Michael Reta File Name: 38346 Spec's Westlake [ground sign].cdr Proposal #: 38346 Job #: n/a Note: Page 1 of 2 MONUMENT Qty: One (1) Set Scale: 1/2" = 1'-0" 1B NOTE: ALL COLORS PER “CIRCLE T RANCH” STANDARDS SURVEY REQ’D FOR SIGN WIDTH Pin mounted, FCO aluminum Circle T Logo Rough Cut Lueders Stone Base - (4) sections, Sawcut interior faces. MET # E113766 No. Circuits: KVA: One (1) 120V/20A .96AMPS:8.0 ELECTRICAL LOAD 1'-10" 4"2"3"2'-9" 3'-3" 6'-0" 7'-4" 8'-0" Poly-carbonate faces 1" Alum. retainer TYP. SECTION: (N.T.S.) D/F ILLUMINATED CABINET w/ POLY-CARBONATE FACES .063" ALUMINUM FILLER .063" x 2½" ALUMINUM RETAINERS 12v LED POWER SUPPLY [IN GALVANIZED BOX] POLY-CARBONATE FACE 2" x 3/16" ANGLE FRAME SERVICE PROVIDED BY OTHER LED MODULE ¼" ALUMINUM SQ. TUBE Scope of Work: Manufacture and install one (1) d/f internally illuminated ground sign - mfg’d per Circle-T’s standards. • .177" Clear poly-carbonate face w/ 2nd surface digital print. • .063" Aluminum returns & Filler. • Fabricated .080" Aluminum crowns & reveal. • All paint to be stipple-texture finish. • .125" Aluminum logo, pin mounted to stone fascia. • White LED Illumination. • Stone, pad & foundation by SSC. Resolution 18-13 Revisions © 2017 State Sign Job Name: THIS DRAWING IS THE EXCLUSIVE PROPERTY OF STATE SIGN. ANY USE OR REPRODUCTION OF THIS DRAWING WITHOUT WRITTEN AUTHORIZATION FROM STATE SIGN IS STRICTLY PROHIBITED. OWNERSHIP AND COPYRIGHT IS RETAINED IN ACCORDANCE WITH U.S. AND INTERNATIONAL TRADEMARK / COPYRIGHT LAWS. CORPORATE OFFICE 7630 HANSEN RD., HOUSTON, TX 77061 P: 713.943.1831 F: 713.943.9771 Proposal Drawing Final Drawing Client: Spec’s Liquor Location: 2341 Hwy 377 S., Westlake, TX 26232 Salesperson: Rani Huffaker Prj. Mngr.: Candy White Date: 1/26/18 Designer: Michael Reta File Name: 38346 Spec's Westlake [ground sign].cdr Proposal #: 38346 Job #: n/a Note: Page 2 of 2 MONUMENT Qty: One (1) Set Scale: 1/2" = 1'-0" 2B NOTE: ALL COLORS PER “CIRCLE T RANCH” STANDARDS SURVEY REQ’D FOR SIGN WIDTH Pin mounted, FCO aluminum Circle T Logo Rough Cut Lueders Stone Base - (4) sections, Sawcut interior faces. MET # E113766 No. Circuits: KVA: One (1) 120V/20A .96AMPS:8.0 ELECTRICAL LOAD 1'-10" 4"2"3"2'-9" 3'-3" 6'-0" 7'-4" 8'-0" Poly-carbonate faces 1" Alum. retainer TYP. SECTION: (N.T.S.) D/F ILLUMINATED CABINET w/ POLY-CARBONATE FACES .063" ALUMINUM FILLER .063" x 2½" ALUMINUM RETAINERS 12v LED POWER SUPPLY [IN GALVANIZED BOX] POLY-CARBONATE FACE 2" x 3/16" ANGLE FRAME SERVICE PROVIDED BY OTHER LED MODULE ¼" ALUMINUM SQ. TUBE Scope of Work: Manufacture and install one (1) d/f internally illuminated ground sign - mfg’d per Circle-T’s standards. • .177" Clear poly-carbonate face w/ 2nd surface digital print. • .063" Aluminum returns & Filler. • Fabricated .080" Aluminum crowns & reveal. • All paint to be stipple-texture finish. • .125" Aluminum logo, pin mounted to stone fascia. • White LED Illumination. • Stone, pad & foundation by SSC. Resolution 18-13 0.1 0.1 0.1 0.1 0.1 0.1 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.4 0.5 0.5 0.5 0.4 0.4 0.3 0.4 0.4 0.5 0.4 0.4 0.4 0.5 0.4 0.4 0.4 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.2 0.4 0.4 0.2 0.2 0.10.20.20.30.4 0.80.60.50.50.50.5 0.8 0.70.70.80.70.60.81.00.90.70.60.91.01.00.91.01.01.00.60.30.2 0.2 0.3 0.3 0.4 0.4 0.3 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.2 0.2 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.2 0.2 0.3 0.4 0.4 0.4 0.4 0.5 0.4 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.8 0.7 0.7 0.7 0.8 0.6 0.4 0.3 0.3 0.4 0.5 0.5 0.4 0.4 0.2 0.1 0.2 0.3 0.3 0.3 0.3 0.3 0.2 0.2 1.1 1.1 1.1 1.1 1.2 1.0 0.8 0.7 0.6 0.7 0.7 0.9 0.7 0.5 0.5 0.5 0.5 0.5 0.5 0.4 0.3 0.1 1.0 1.3 2.2 2.1 2.1 1.3 1.1 1.5 1.6 1.7 1.7 1.5 1.5 1.2 1.2 1.1 0.9 0.7 0.8 0.8 0.8 0.7 0.6 0.1 1.2 2.2 2.6 3.0 3.2 1.8 1.7 1.9 2.6 2.5 2.3 2.0 2.1 1.8 2.1 1.9 1.2 1.1 1.5 1.2 0.9 0.6 0.4 0.1 1.1 2.3 2.9 3.0 3.3 2.3 2.0 2.5 2.7 2.2 1.6 1.6 1.6 1.4 1.7 1.7 1.1 1.5 2.3 1.9 1.4 1.0 0.4 0.1 1.3 2.3 3.3 3.4 3.6 2.9 2.7 2.8 2.4 2.0 1.5 1.3 1.1 1.3 1.4 1.4 1.2 1.8 2.5 1.7 1.4 0.8 0.5 0.2 1.1 1.3 2.2 2.5 2.9 2.5 2.1 1.8 1.7 1.8 1.5 1.5 1.5 1.4 1.5 1.6 1.9 2.3 2.6 1.8 1.4 1.0 0.8 0.5 0.3 0.9 1.1 1.6 2.2 2.8 2.9 3.1 5.2 4.8 3.6 5.6 5.5 3.8 5.6 5.4 3.6 3.3 3.6 3.6 2.8 2.1 1.4 1.1 0.8 0.5 0.8 1.5 1.7 2.3 2.5 2.6 1.3 3.2 3.3 3.4 3.7 3.5 3.2 2.1 1.2 0.8 0.5 1.0 1.5 1.9 2.3 2.3 4.2 3.9 4.4 4.4 2.7 3.6 3.1 3.1 1.9 1.3 0.8 0.4 1.1 1.2 1.4 1.5 1.5 3.2 2.1 6.2 4.9 2.1 3.4 3.4 3.0 1.9 1.5 0.9 0.5 1.0 1.4 1.8 1.8 1.7 1.5 2.1 2.9 1.6 2.3 2.1 2.2 1.8 1.8 1.0 0.5 1.0 1.5 1.8 2.1 2.2 1.0 1.2 1.9 1.3 1.5 1.8 2.4 2.8 2.7 1.1 0.5 0.7 1.1 1.4 1.9 1.9 2.1 2.5 2.0 1.1 1.3 1.8 2.0 2.5 2.5 0.9 0.5 0.8 1.0 1.6 1.9 2.0 4.9 5.3 2.1 1.1 1.2 1.4 1.7 1.9 2.0 0.9 0.6 0.8 0.9 1.7 2.0 2.1 4.4 3.1 2.1 1.2 1.4 1.3 1.9 2.1 2.2 1.2 0.8 0.8 1.2 1.4 1.8 1.8 2.4 2.0 1.5 1.2 1.3 1.4 1.9 2.2 2.2 1.2 0.8 1.0 1.6 1.7 2.3 2.4 2.7 3.0 2.0 1.3 1.4 1.6 2.0 2.5 2.5 1.1 0.6 0.8 1.2 1.5 2.0 2.3 2.2 5.0 3.8 2.2 1.4 2.0 2.3 2.5 2.8 2.9 1.0 0.5 0.7 1.0 1.3 1.7 2.1 1.8 4.7 2.2 2.1 2.0 3.0 3.2 3.1 2.5 2.3 1.0 0.4 0.8 1.4 1.9 2.2 2.4 1.8 4.7 3.2 4.7 2.8 3.1 3.9 3.5 3.3 2.2 1.5 0.9 0.6 0.7 1.0 1.5 1.7 2.5 1.9 5.3 6.5 3.1 3.2 3.7 3.6 3.5 2.1 1.3 0.8 0.5 0.9 1.1 1.4 1.8 2.4 2.2 2.9 0.7 5.7 3.4 3.2 0.2 5.5 3.8 3.6 3.0 3.3 3.7 3.4 2.8 1.8 1.3 0.9 0.6 1.3 1.9 2.7 3.4 3.5 2.6 3.3 3.5 3.2 3.4 2.9 2.0 2.1 3.0 3.0 1.7 2.1 2.2 2.6 2.0 1.6 1.3 1.1 0.7 0.5 1.8 3.0 3.4 3.6 3.5 2.5 2.5 2.4 1.7 1.0 0.8 0.7 0.7 0.6 0.6 0.7 1.2 1.8 2.5 1.8 1.5 1.0 0.7 0.6 0.5 1.6 2.8 2.9 3.5 3.0 2.0 2.1 2.4 1.6 1.2 0.9 0.6 0.6 0.8 0.7 0.6 0.7 1.8 2.7 2.1 1.7 1.3 0.7 0.7 0.6 1.4 2.3 3.0 3.3 2.5 2.1 2.2 2.3 1.6 1.4 1.0 0.6 0.7 0.9 0.7 0.9 1.2 1.8 2.2 2.0 1.6 1.5 0.9 0.8 0.7 1.0 1.5 1.7 2.3 2.6 2.5 2.2 2.0 1.4 1.4 1.1 0.7 0.6 0.8 0.7 1.3 1.5 1.6 1.8 1.7 1.7 1.8 1.5 0.9 0.6 1.1 1.1 1.1 1.6 3.0 2.7 2.2 1.9 1.6 1.7 1.0 0.7 0.5 0.6 0.9 1.7 1.9 1.7 1.9 1.9 1.9 2.2 1.7 0.9 0.5 0.7 0.7 0.8 1.4 2.5 2.1 2.1 2.1 2.3 2.2 1.1 0.7 0.6 0.7 1.0 1.7 2.1 1.9 2.2 2.0 2.0 2.2 1.6 0.8 0.6 0.5 0.6 1.0 1.4 2.3 2.0 2.1 2.0 2.3 2.4 1.0 0.6 0.5 0.5 0.5 0.7 0.8 1.0 1.3 1.2 0.9 0.8 0.7 0.5 0.4 0.4 0.6 0.9 1.5 2.5 2.1 1.9 1.9 2.0 2.1 1.1 0.6 0.4 0.4 0.3 0.2 0.2 0.4 0.7 0.7 0.4 0.2 0.2 0.4 0.2 0.3 0.5 0.7 1.2 2.2 2.1 1.8 1.9 2.0 2.2 1.2 0.7 0.4 0.3 0.1 0.1 0.1 0.2 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.2 0.3 0.4 1.0 2.4 2.2 1.9 1.9 1.8 1.9 1.0 0.6 0.3 0.2 0.1 0.1 0.1 0.1 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.2 0.2 0.3 0.8 2.1 2.1 1.9 1.9 1.7 1.9 0.8 0.3 Statistics Description Symbol Avg Max Min Max/Min Avg/Min Area Overall Photometric 1.6 fc 6.5 fc 0.0 fc N/A N/A Dumpster 2.5 fc 5.6 fc 1.5 fc 3.7:1 1.7:1 Entrance East 1.9 fc 2.2 fc 1.7 fc 1.3:1 1.1:1 Entrance South 1.1 fc 1.6 fc 0.7 fc 2.3:1 1.6:1 North Entrance 2 0.7 fc 0.7 fc 0.6 fc 1.2:1 1.2:1 North Entrance 1 0.2 fc 0.3 fc 0.1 fc 3.0:1 2.0:1 Parking & Driving Proposed Addition 1.8 fc 5.6 fc 0.4 fc 14.0:1 4.5:1 Parking & Drving Existing Store 2.0 fc 5.3 fc 0.6 fc 8.8:1 3.3:1 Site Property Line 0.4 fc 1.0 fc 0.0 fc N/A N/A Walkway Proposed Addition 3.3 fc 6.2 fc 1.2 fc 5.2:1 2.8:1 Schedule Symbol Label QTY Catalog Number Description Lamp Number Lamps Lumens per Lamp LLF Wattage Mounting Height A 4 G18-3XL-250PSMH-HS GULLWING CLEAR HORIZONTAL 250PSMH RATED FOR 22000 LUMENS 1 22000 0.81 582 B 6 G18-3XL-250PSMH-HS GULLWING CLEAR HORIZONTAL 250PSMH RATED FOR 22000 LUMENS 1 22000 0.81 291 G 14 EWS3_A7E150_____- 120-277V GE Evolve LED Area Light - Scalable - Wall Pack - EWS3 LED 1 2900 0.81 25 Phillips Gardco Area Luninaire 3' Pole Base 25' Pole 3' Pole Base 25' Pole 12' Wall Mount Philips Gardco Area Luminaire B B B B B B A A A A G G G Dumpster Entrance East Entrance South North Entrance 2North Entrance 1 Parking & Driving Proposed Addition Parking & Drving Existing Store Site Property Line Walkway Proposed Addition Site Photometrics Plan Scale: 1/16" = 1'-0" SITE PHOTOMETRIC PLAN ES1.1 DRAWN BY: AH CHECKED BY: AH PROJECT NUMBER: DATE: REVISIONS: 16-703 02-12-2018 3/9/2018 10755 SANDHILL ROAD | DALLAS, TEXAS 75238 | O: 214-343-9400 | F: 214-341-9060 | dimensiongrp.comARCHITECTURE ● CIVIL ENGINEERING ● MEP ENGINEERING ● PLANNINGSPECS2341 US 377WEST LAKE, TEXASPhilips Gullwing Luminaire GE EWS3 Wall Pack POLE AND BASE FOR POLE LIGHTING TO MATCH EXISTING Resolution 18-13