HomeMy WebLinkAboutEntrada Residential Site PlansTCOURTYARDCOURTYARDCOURTYARDSIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKCOURTYARDCOURTYARDMAILBOXESCOURTYARDCOURTYARDTTRASHCANS5' ACCESS EASEMENT7.5' ACCESS/UTILITYEASEMENT5' UTILITY EASEMENT24' UTILITY/ACCESSEASEMENTSIDEWALK SIDEWALK SIDEWALKLOT: 11LOT: 12LOT: 13LOT: 14LOT: 15LOT: 161st FLOORLOT111,860SQUARE FOOTAGE2nd FLOORTOTAL A/C1,2803,140AUTOMOBILETOTAL121,5891,973141516COV'D ENTRY498TERRACEMECHANICAL31COURTYARD510BALCONY25665283,562529131,862455522--294932528161,8581,8211,5875355251,426391,4651,6181,0165313482337114114917056100322-3,2883,3233,2052,837------4,2085,0254,3454,6554,8793,78526,897SCALESHEETDATEA1.011" = 10'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIA PD SITE PLAN / COVER SHEET/ GENERAL NOTESFIRST FLOOR PLAN - LOT:11A2.02COLD WATER TAP FOR REFRIGERATOR OR ICE MAKERSWITCHED GAS KEYFROST FREE HOSE BIBA1.01GASGAS SUPPLYGAS KEYHBWGASA2.011.PLUMBING AND HVAC SYSTEMS:1.1.DESIGNED BY CONTRACTORS PLUMBING AND MECHANICAL PERSONNEL.1.2.PROPOSED LOCATIONS OF HVAC AND WATER HEATERS DETERMINED BY CONTRACTOR AND SUBMITTED TO OWNERAND ARCHITECT FOR APPROVAL.1.3.PROPOSED LOCATIONS OF HVAC VENTS AND RETURN AIR DETERMINED BY CONTRACTOR AND SUBMITTED TOOWNER AND ARCHITECT FOR APPROVAL.2.ALL VENTILATION SYSTEMS TO MEET LOCAL CODE REQUIREMENTS AND DESIGNED BY CONTRACTORS PERSONNEL.1.CONSTRUCTION:COMPLY WITH APPLICABLE CODES AND RELATED AMENDMENTS.2.THESE DRAWINGS DO NOT CONTAIN COMPLETE SPECIFICATIONS, DETAILS, OR FULL INFORMATION NECESSARY FOR THECOMPLETE CONSTRUCTION OF THE PROJECT. ADDITIONAL INFORMATION SHALL BE OBTAINED FROM THE OWNER.3.NOTIFY ARCHITECT AND OWNER OF ERRORS, OMISSIONS, AND DISCREPANCIES IN CONTRACT DOCUMENTS, OR BETWEENCONTRACT DOCUMENTS AND ACTUAL SITE CONSTRUCTION CONDITIONS. ERRORS, OMISSIONS, AND DISCREPANCIESMUST BE RESOLVED AND DOCUMENTED BEFORE CONTINUING CONSTRUCTION WITH THE WORK IN QUESTION. FAILURETO NOTIFY THE OWNER AND ARCHITECT IN SUCH AN EVENT SHALL CONSTITUTE ACCEPTANCE OF ANY RESULTINGOBLIGATIONS OR RESPONSIBILITIES WITH REGARDS TO DELAYS, COSTS, CODE COMPLIANCE, AND LEGAL REMEDIESRESULTING FROM THIS OR RELATED WORK.4.CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS BY OWNERS CONSULTANTS.4.1.ARCHITECT'S ELECTRICAL, MECHANICAL, AND PLUMBING PLANS ARE DIAGRAMMATIC ONLY. ACTUAL DESIGN BYOWNER'S CONSULTANT.4.2.REFER TO CIVIL AND LANDSCAPE DRAWINGS FOR GRADING AND DRAINAGE REQUIREMENTS.4.3.REFER TO STRUCTURAL ENGINEER FOR STRUCTURAL DESIGN, SPECIFICATIONS, AND DETAILS; INCLUDING REQUIREDRETAINING WALLS, WATERPROOFING, AND FRENCH DRAIN SYSTEMS.4.4.COORDINATE SOIL COMPACTION REQUIREMENTS BEHIND RETAINING WALLS WITH STRUCTURAL ENGINEER.5.THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE SITE AND BE RESPONSIBLE FOR THE ACCURACY ANDCORRECTNESS OF SAME.6.VERIFY TYPE AND LOCATION OF UTILITIES SERVING SITE.7.FIREPLACES:7.1.VERIFY SIZES, INCLUDING HEARTH EXTENSIONS REQUIRED BY CODE.7.2.PROVIDE OUTSIDE MAKE-UP AIR INLET AND SCREENED LOUVER AND DAMPER.8.VENT CLOTHES DRYER TO OUTSIDE.9.REFER TO ELEVATIONS FOR ROOFS TO BE GUTTERED. SUBMIT PROPOSED LOCATIONS OF GUTTERS AND DOWNSPOUTS TOOWNER AND ARCHITECT FOR REVIEW AND APPROVAL.10.ALL FLOOR FINISH HEIGHTS TO MATCH. FLOOR ELEVATIONS AT SECOND FLOOR ARE GIVEN TO TOP OF FLOOR DECK.11.INSTALL STUDS AT CLOSET SIDE WALL ROD LOCATIONS, MEASURED 10" FROM BACK WALL.12.EXTERIOR MATERIALS AND FINISHES ARE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS WRITTENINSTRUCTIONS AND DETAILS.13.FIRE SPRINKLERS SYSTEMS: REFER TO LOCAL JURISDICTION FOR REQUIREMENTS.14.SHOP DRAWINGS SHALL BE SUBMITTED TO OWNER AND ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND INSTALLINGANY EQUIPMENT. I.E. WINDOWS, STEEL, CAST STONE....ETC.15.THE CONTRACTOR SHALL PAY ALL FINES, GIVE ALL NOTICES, FILE ALL NECESSARY DRAWINGS, AND OBTAIN ALL PERMITSAND CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH ALL WORK UNDER THE CONTRACT DOCUMENTS.FOR DIMENSION PURPOSES:1.DO NOT SCALE DRAWINGS.2.VERIFY DIMENSIONS: NOTIFY ARCHITECT OF ANY DISCREPANCIES.3.WOOD STUD WALLS: 2x4'S @ 16" O.C. TO A MAXIMUM HEIGHT OF 10'-0", SUPPORTING ONE FLOOR, ROOF, AND CEILING.UNSUPPORTED WALL HEIGHTS EXCEEDING 10'-0" AND 3 STORY CONDITIONS REQUIRE STRUCTURAL ANALYSIS TODETERMINE STUD SIZE AND SPACING.4.EXTERIOR WOOD STUD/MASONRY ASSEMBLIES:9" w/2x4's, 11" w/2X6's, 13" w/2x8's5.INTERIOR WOOD STUDS DIMENSIONED TO CENTERLINE OF WALL. EXCEPTION: FLAT STUDS DIMENSIONED 2" THICKAND OVER 6" THICK STUD WALLS DIMENSIONED OUT-TO-OUT.6.WALL PLATE HEIGHTS: CROSS REFERENCE EXTERIOR ELEVATIONS, WALL SECTIONS, AND FASCIA DETAILS TODETERMINE.7.WINDOWS AND DOORS:7.1.VERIFY ROUGH OPENINGS WITH SELECTED MANUFACTURER.7.2.REFER TO EXTERIOR ELEVATIONS AND FLOOR PLANS OR SCHEDULE FOR HEAD HEIGHTS.Westlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/2016ROOF PLANS - 1/8" SCALEA1.02FIRST FLOOR PLANS - 1/8" SCALEA1.03SECOND FLOOR PLANS - 1/8" SCALEA1.04FIRST FLOOR PLAN - LOT:12A2.03A2.04A2.05A2.06FIRST FLOOR PLAN - LOT:13FIRST FLOOR PLAN - LOT:14FIRST FLOOR PLAN - LOT:15FIRST FLOOR PLAN - LOT:16SECOND FLOOR PLAN - LOT:11SECOND FLOOR PLAN - LOT:12SECOND FLOOR PLAN - LOT:13SECOND FLOOR PLAN - LOT:14SECOND FLOOR PLAN - LOT:15SECOND FLOOR PLAN - LOT:16A2.07A2.08A2.09A2.10A2.11A2.12ELEVATIONS: A3.01/01,02,03A3.01ELEVATIONS: A3.02/01,02A3.02ELEVATIONS: A3.03/01,02,03A3.03ELEVATIONS: A3.04/01,02A3.04ELEVATIONS: A3.05/01,02A3.05ELEVATIONS: A3.06/01A3.06DETAILSA4.01DETAILSA4.02DETAILSA4.03SCHEDULESA4.0404/11/20164/20/2016 10:44:56 AM, BUSH DESIGN & ASSOC.
T4:12RAKERAKERIDGERIDGE CRICKETRAKERAKE4:12RIDGERAKERAKERAKE RAKERIDGE RAKERAKERAKEPARAPET WALLRIDGERAKERIDGERIDGERIDGERIDGEVALLEYVALLEYRAKERAKE
RIDGE RIDGERI
D
G
E
RI
D
G
ERIDGERI
D
G
E
RI
D
G
E
RIDGE
RIDGERIDGE
RI
D
G
E
RAKERAKERIDGE
V
A
L
L
E
Y
VALLEYRAKERAKERAKERAKECRICKETRAKERAKERAKERAKERAKER
A
K
E
RAKERAKE RAKEVALLEYVALLEYCRICKETRAKERAKERAKERAKERAKERAKEVALLEYR
A
K
E
R
A
K
EVALLEYRAKERAKERAKERAKERAKERAKERAKERAKERIDGERAKERI
D
G
E
VALLEYVALLEY
R
A
K
E
R
A
K
E RIDGERAKERAKEPARAPET WALLRIDGECOURTYARDCOURTYARDCOURTYARDTERRACETERRACECOURTYARDRAKEVALLEYRAKE4:124:124:12RI
D
G
E
VALLEY 3:124:12RAKERAKE
RAKE
RAKERAKETRELLIS
TERRACETERRACECOURTYARDSCUPPERSCUPPER4:12
4:12
4:124:124:12
4:12
4:12
4:12
4:12
4:
1
24:124:12
4:12
4:124:
1
2
4:
1
2
4:
1
2
4:
1
2
4:
1
2
4:12
4:12 4:124:124:12 4:124:12 4:124:12
4:124:12 4:12 4:124:12 4:124:124:12 4:124:124:124:124:124:124:124:12
4:124:
1
2
4:
1
2
4:12RAKECRICKET4:124:12
4:
1
2
4:
1
2 RAKERAKE RAKE CRICKETCOURTYARDR
A
K
E
4:
1
2
4:124:12R
A
K
E
RAKERAKER
A
K
E
R
A
K
E
4:
1
2
4:
1
2
4:
1
2
4:
1
2
4:124:124:
1
2 4:124:12VALLEYVALLEYVALLEY4:124:12RIDGERI
D
G
E
4:
1
24:12CRICKETRAKE4:12
6:124:12RIDGE1.625:12FLAT ROOFPARAPET WALLPARAPET WALL SCUPPERA3.06/01A
3
.
0
2
/
0
2
A
3
.
0
2
/
0
1A3.03/02A3
.
0
5
/
0
2
A
3
.
0
2
/
0
2
A
3
.
0
5
/
0
2A3.04/02A
3
.
0
2
/
0
1A3.04/01A3.01/03A3.01/03A
3
.
0
1
/
0
2
A3.01/01A3.01/01A3.03/01A3.03/01A3.03/03A3.03/03A3.04/02A3.04/01A3.05/01A
3
.
0
5
/
0
2
4:124:124:12CRICKETA/
C
P
L
A
T
F
O
R
M
-
L
O
T
1
4
A/C PLATFORM - LOT 15
A/C PLATFORM - LOT 12 RIDGE4:12RAKERAKEA/C PLATFORM - LOT 13
A3.05/01A3.05/01SCALESHEETDATEA1.021/8" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:44:59 AM, BUSH DESIGN & ASSOC.
10'-1" CLG HT10
'
-
1
"
C
L
G
H
T10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTWC10'-1" CLG HTW
D
WCLAV10'-1" CLG HT10'-1" CLG HT10
'
-
1
"
C
L
G
H
TW
DWC
LAV 10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTSLOPED CLG10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTLAVLAVWC10'-1" CLG HT10'-1" CLG HTWCLAV10'-1" CLG HT10'-1" CLG HT10
'
-
1
"
C
L
G
H
T
W D10'-1" CLG HTWC10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTWCWCLAVLAV10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT 10'-1" CLG HT10'-1" CLG HTWCLAV10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT
10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTLAV10'-1" CLG HTWC10'-1" CLG H
T10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTW D
WDWCLAV10'-1" CLG HTSHOWERSE
A
T
TUBLINENWH10'-1" CLG HTTUB/SHOWERLI
N
E
N10'-1" CLG HTLAVBUILT-INBUILT-INTUBTUBWHWH10
'
-
1
"
C
L
G
H
T
TUBSHOWER SEATLINEN SHOWERSHOWER
SEAT48" REF.48" REF.LOCKERS
LOCKERSBUILT-INBUILT-INFIRE PLACE42" FIRE PLACEFIRE PLACEFIRE PLACE FIRE PLACESINK
DW
KS
SINKSINK
SINK
48" HALF
W
A
L
L
48" H
A
L
F
W
A
L
L
D
W48" HALF
WALL48" HALF WALL W/ ARCH ABOVEOPEN TO ABOVE9-
1
"
C
L
G
H
T
WC10'-1" CLG HT48" REF.SINK MDDW TD42" RANGE W/ HOOD 48" REF.MDSINK DW48" RANGE W/ HOODLOCKERSSEATW
D
SI
N
K
SINK48" REF.48" REF.48" REF.SINKSINK
DW TD
SINK
SINKSINK
SI
N
K
D
W MDREFMDDW TD48" RANGE W/ HOOD
48" RANGE W/ HOOD
DW48" RANGE W/ HOOD48" REF.MD SINK48
"
R
A
N
G
E
W
/
H
O
O
D
M
DLAVLAVGRILL W/ HOOD
BUILT-INSEATSHOWERTUB 10'-1" CLG HT48" 48" REF.MDSINKSEAT DW48" RANGE W/ HOODPHANTOM CAB.LAVMD 6'-10"25'-0"4'-11"4'-5"17'-1"3'-0"3'-4"6'-8"11'-0"6'-8"24'-4"24'-5"52'-1"4'-5"3'-4"17'-2"28'-0"17'-2"10"1'-11"6'-512"3'-912"3'-0"41'-214"7'-5"3'-4"10'-9"14'-11"4'-8"8'-8"8'-8"4'-0"4'-10"8'-1012"3'-1112"5'-10"4'-134"5'-6"8'-10"4'-8"4'-8"3'-8"2'-10"4'-8"4'-8"2'-2"6'-4"9'-4"10'-414"7'-4"4'-4"3'-4"19'-7"17'-4"8'-10"18'-8"13'-1014"18'-0"26'-0"14'-4"27'-4"2'-3"5'-11"11'-934"5'-7"4'-11"3'-3"7'-012"7'-012"8'-2"14'-1"19'-3"8'-912"8'-912"2'-10"5'-0"17'-714"8'-5"4'-10"1'-8"1'-8"16'-0"6'-10"8'-934"3'-2"3'-2"3'-6"1'-4"1'-4"FLUSH HEARTH25'-514"12'-7"4'-4"8'-3"8'-0"1'-10"6'-10"3'-8"4'-8"2'-2"31'-10"10'-134"3'-9"10'-214"2'-412"13'-314"2'-712"6'-114"20'-012"18'-314"3'-914"2'-634"5'-612"2'-634"5'
-612"
2
'
-
6
3
4"
5'
-
6
1
2"
2'-
6
3
4"
10'
-
3
"
10'-41
4"3'-0"11'-2"11'-0"11'-0"6'-8"
53'-21
2"
3'-0"
3'-0"
5'-7"
8"
5'-51
4"
3'
-
1
1
4"
4'
-
1
3
4"
8'
-
4
"
8'
-
4
"
4'
-
2
1
2"
5'
-
6
1
2"
33
'
-
8
"2'-1014"4'-4"7'-10"7'-10"4'-4"6'-10"3'-1"15'-8"9'-11"6'-634"10"4'-4"1'-0"5'-0"3'-8"10"2'-414"4'-212"1'-2"4'-9"6'-4"2'-10"8"2'-10"4'-11"2'-1"2'-8"1'-8"10'-134"3'-1"10"9'-012"6"6'-0"1'-2"21'-4"1'-2"4'-0"6"4'-0"5'-8"8'-4"9'-0"10"17'-93
4"4'-8"
4"
10"3'-4"5'-8"
4'-51
2"2'-6"
10"3'-8"7'-2"3'-0"3'-4"10"3'-6"13'-0"10"5'-10"6"7'-03
4"3'-0"6'-111
2"
17'-0"
1'-2"13'-10"2'-2"9'-6"7'-33
4"3'-4"4'-0"2'-8"4'-2"
2'-4"
6"
19'-21
2"
111
4"9'-23
4"1'-2"2'-10"2'-103
4"2'-8"
8'-6"10"4'-5"4'-5"8"
6'
-
7
1
2"
5'
-
9
1
2"
5'-
6
1
2"
10
"
1
1
'
-
9
"
8"
17
'
-
8
"
6"
1'
-
4
"
5'
-
1
0
"
12
'
-
8
"
1
6
'
-
3
"
2'
-
2
"
1
0
"
22
'
-
8
"
1
0
"
6'
-
0
"
10
"
1
6
'
-
5
"
6'
-
3
"
8'
-
9
"
3'
-
7
"
3'
-
7
"
8'
-
0
1
2"
1
2
'
-
5
"
11
'
-
4
1
2"
3
1
'
-
1
"
1
0
"
2'-9"1'-73
4"
5'-
0
"
7'
-
7
"
7'
-
7
"
3'
-
8
"
6'
-
8
"
11
'
-
0
"
6'
-
8
"
6'
-
8
"
11
'
-
0
"
6'
-
8
"
3
1
'
-
1
"
23
'
-
9
1
2"
54
'
-
8
"
23
'
-
1
1
"
21
'
-
5
1
2"
9'
-
6
"
8'
-
7
1
2"
3'
-
4
"2'-10"1'-0"9'-1"19'-012"20°70°2'-812"5'-0"3'-514"1'-10"10'-4"2'-1114"6'-10"6'-10"6'-8"
1
1
'
-
0
"
6'
-
3
"
6'
-
3
"
1
1
'
-
0
"
6'
-
8
"
13'-8"
2
3
'
-
1
1
"
2
3
'
-
1
1
"
7'
-
6
"
7'
-
6
"
3'
-
2
"
2'
-
3
"
2
2
'
-
4
"
20
'
-
5
"
42
'
-
9
"
37'-8"
A
3
.
0
2
/
0
1
A3
.
0
5
/
0
2A3.06/01A
3
.
0
2
/
0
2
A
3
.
0
5
/
0
2
A
3
.
0
2
/
0
2
A
3
.
0
2
/
0
1
A3.01/03A3.06/01A3.01/03A
3
.
0
1
/
0
2
A3.01/01A3.01/01A3.03/01A3.03/01A3.03/02A3.03/03A3.03/03A3.04/02A3.04/02A3.04/01A3.04/01A
3
.
0
5
/
0
2
3'-0"6'-0"13'-83
4"10"3'-4"2'-4"5'-8"4'-1012"6"9'-0"6'-4"16'-10"4'-4"1'-10"1'-4"6"3'-4"4'-0"8'-111
4"
1'-2"
17'-6"FIXED LAV5'-71
2"
38°2'-8"11"FL
U
S
H
H
E
A
R
T
H
31'-114"7'-812"3'-112"10"2'-0"5'-10"3'-4"22'-4"1'-4"6"13'-4"5'-8"6"20'-8"1'-4"2'-10"6"5'-4"2'-2"2'-2"23'-0"
10"4'-51
2"8'-03
4"4'-111
2"8"
2'
-
8
"
3'-
1
0
1
2"
3'
-
1
0
1
2"
2'-
4
"
1
1
'
-
1
0
1
2"
7'-71
2"10"17'-2"10"
8'-10"
16'-73
4"6'-5"1'-0"12'-2"2'-0"4'-514"2'-114"15'-6"10"2'-212"1'-8"28'-0"10"13'-6"1'-10"1'-10"2'-4"17'-2"24'-412"12'-434"2'-034"12'-614"4'-4"1'-4"2'-4"10"21'-4"8"6'-10"7'-2"4'-6"12'-10"6"2'-0"3'-8"3'-6"10"4'-6"13'-6"10"8"4'-0"4'-0"10"2'-6"14'-6"8"7'-0"10"7'-2"1'-0"8"1'-0"1'-0"3'-414"15'-6"1'-2"1'-2"14'-0"11'-6"10'-2"3'-4"3'-10"6"7'-0"6"3'-8"2'-4"10'-1134"3'-234"2'-912"3'-6"10"3'-4"8"6'-4"23'-2"4'-0"1'-6"10"1'-6"1'-8"10"14'-8"3'-6"3'-10"7'-0"7'-0"3'-4"2'-10"1'-2"3'-6"7'-0"7'-0"7'-0"7'-0"4'-6"6"3'-0"1'-2"7'-0"7'-0"22'-0"4'-934"3'-6"FLUSH HEARTH1'-
0
"
2'-4"2'-0"KS
2'-
2
"
1'
-
0
"
10
"
4'
-
0
"
5'
-
6
"
6"
8'-
8
"
4'-0"4'-734"10'-9"1'-8"21'-0"10"3'-4"10'-2"1'-4"1'-2"6'-2"2'-4"10'-10"10"10"9'-0"9'-0"8"2'-0"6'-0"10"7'-934"6'-10"2'-414"8"3'-6"3'-6"1'-5"6"9'-3"5'-1"10"13'-7"4'-1034"8'-314"6'-3"FLUSH HEARTH8"
2'-
6
"3080 F. ARCH8"11111122171313171881913131111184'-334"2'-714"171820
20
20
20
202013101713131313171216161110191417146'-8"1812'-1"5'-10"1'-4"171919191111113'-0"15'-2"
2'-6"7'-2"5'-6"1717171717171313131313999141818181'-8"1312161317111820
20
14158'-4"111114141414141
0
"
2'
-
9
"
16
'
-
3
"
3'
-
8
"
5'
-
8
"
4'
-
3
"
2'
-
8
"
1'
-
1
1
"
13
'
-
5
"
1
0
"1'-214"3'-9"3'-012"1'-2"11121310131911 159'-4"151515
15
15
1516191920 20202021ABOVE2019191
9
1919
19191920
15
22
22
22
231919191919191919151515153'-6"2'-312"1'-2"5'-312"18'-0"8'-2"4'-434"2'-8"6'-114"6'-3"1'-0"2'-0"3'-734"2'-8"6'-4"6'-4"2'-8"42"FLUSH HEARTH
6'-0"10'-714"
4'
-
0
"
1
0
"2'-10"10'-5"3'-4"23'-0"10"3'-2"10
"
1
7
'
-
1
0
"
4'
-
1
0
"
10"18'-114"4'-634"8'-11"
10
'
-
1
"
C
L
G
H
T
20
20
2020GRILL W/ HOODGRILL W/ HOODG
R
I
L
L
W
/
H
O
O
D 2'-6"1'-8"6"10'-034"2'-8"16'-8"1'-4"10"14'-9"6'-7"5'-0"10"4'-5"4'-5"8"7'-1"9'-1"2'-0"6"3'-2"6"2'-2"4'-2"3'-10"10"7'-812"10'-412"1'-2"15'-11"6'-8"10"2'-10"1'-6"5'
-
1
0
1
2"10"4'-0"2'-012"2'-0"2'-0"6"3'-4"6"3'-6"6"6'-2"10"13'-4"10'-0"3'-6"2'-8"1'2'-4"13'-4"10"3'-10"1'-0"
1
2
'
-
6
3
4"
12
'
-
0
"
1'
-
6
"2'-034"6'
-
0
"
6"
3'
-
8
"
3'
-
0
"
4'-
2
"
2'
-
9
"
10
"
4'-534"3'-7"3'-7"10"5'-7"7'-10"12'-9"10"4'-4"4'-0"8"4'-4"8'-2"1'-2"3'-4"W/ 7'-6" S.L.118080 F. ARCHW/ 7'-6" S.L.
RAISED HEARTH
RAISED HEARTH 5'-3"3'-5"7680 F. ARCHW/ 7'-6" S.L.7080 EB ARCHW/ 7'-6" S.L.7080 EB ARCHW/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.9080 EB ARCHW/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.15680 EB ARCHW/ 7'-6" S.L.4080 F. ARCHW/ 7'-6" S.L.4080 F. ARCHW/ 7'-6" S.L.4080 F. ARCHW/ 7'-6" S.L.4080 F. ARCH
W/ 7'-6" S.L.13080 EB ARCHW/ 7'-6" S.L.13080 EB ARCH
W/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.3080 F. ARCH
W/ 7'-6" S.L.6880 EB ARCHW/ 7'-6" S.L.6880 EB ARCHW/ 7'-6" S.L.7080 EB ARCH
W/ 7'-6" S.L.8980 F. ARCHW/ 7'-6" S.L.6'-6"6'-91
2"4'-2"3080 F. ARCHW/ 7'-6" S.L.STEPSUP(19)STEPSUP(19)STEPSUP(19)STEPSUP(19)STEPSUP(19)STEPSUP(19)STEPSUP(19)5080 F. ARCHW/ 7'-6" S.L.5080 F. ARCHW/ 7'-6" S.L.5080 F. ARCHW/ 7'-6" S.L.5080 F. ARCHW/ 7'-6" S.L.5080 F. ARCHW/ 7'-6" S.L.GROIN VAULTFROM 8'-7" TO 10'-1" 5080 F. ARCHW/ 7'-6" S.L.FRDGEGROIN VAULTFROM 8'-7" TO 10'-1" KSSINK
3080 F. ARCHW/ 7'-6" S.L.8"5080 F. ARCH
W/ 7'-6" S.L.4"5080 F. ARCHW/ 7'-6" S.L.5080 F. ARCHW/ 7'-6" S.L.71
8
0
F
.
A
R
C
H
W
/
7
'
-
6
"
S
.
L
.5080 F. ARCHW/ 7'-6" S.L.71
8
0
F
.
A
R
C
H
W
/
7
'
-
6
"
S
.
L
.
21 212121K.S.36'-6"47'-1"4'-8"3'-5"5'-5"5'-3"6'-8"1'-10"13'-11"10"18'-6"14'-0"10"10"6'-10"1'-10"1'-2"2'-2"1'-0"FL
U
S
H
H
E
A
R
T
H
FLUSH HEARTHK.S.HANDRAIL HANDRAILHANDRAILH
A
N
D
R
A
I
L
HANDRAIL212'-0"24111
4"2'-0"1'-012"2'-2"4'-1114"1'-10"23
3'
-
0
"
3'
-
0
"4'-4"4'-0"LAVLAVLINENBUILT-INBUILT-IN6"
1'-6"
8'-101
2"2'-9"1'-11
2"1'-5"3'-
2
"
101
2"
4'
-
6
1
2"1'-7"3'-5"4'
-
2
"2'-8"4'-1012"FIRE PLACERAISED HEARTH6'-4"8"6'-6"7'-0"FIRE PLACEFIRE PLACE
FIRE PLACE 21'-2"3'-10"6'-10"5'-114"17'-10"52°88'-012"6'-1"3'-0"2'-012"3'-6"1'-0"FIRE PLACE8'-8"3'-10"2'-5"6'-2"A3.05/01SCALESHEETDATEA1.031/8" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:00 AM, BUSH DESIGN & ASSOC.
9'-1" CLG HTLAV10'-1" CLG HT10'-1" CLG HT9-1" CLG HT10'-1" CLG HTLAVWCWCLAV9'-1" CLG HT9-1" CLG HT9'-1" CLG HTLAVWCWCWCLAV9-1" CLG HT9-
1
"
C
L
G
H
T9'-1" CLG HT9'-1" CLG HT9-
1
"
C
L
G
H
T
9-1" CLG HT9-1" CLG HT9-1" CLG HTWCLAV9-1" CLG HTWCLAV9'-1" CLG HT9'-
1
"
C
L
G
H
T
9'-1" CLG HT9-
1
"
C
L
G
H
T
9'-
1
"
C
L
G
H
T
9-1" CLG HT9-
1
"
C
L
G
H
TLAVWC9-1" CLG HTWC9-1" CLG HT9-1" CLG HT9-1" CLG HTWCLAVLAV9-1" CLG HTLAVWCLINEN9-1" CLG HT9-1" CLG HT9'-1" CLG HTWCWCLAVLAVLAVB
U
I
L
T
-
I
N
TUB/SHOWERTUB/SHOWERTUB/SHOWER
TUB/SHOWERBUILT-INSHOWERSEATBUILT-INSHELVES
T
U
B
/
S
H
O
W
E
R
T
U
B
/
S
H
O
W
E
ROPEN TO BELOWHAND RAILSHOWERT
U
B
/
S
H
O
W
E
R
BUILT-IN9-1" CLG HT9'-1" CLG HT9'-1" CLG HT9-1" CLG HTVANITYBUILT-INSHOWER SEAT9'-1" CLG HT9'-1" CLG HTTUB/SHOWER SHOWERSEATLAVTUBWCTUB/SHOWER LINENLINENTUB/SHOWER9'-1" CLG HT9-1" CLG HT9-1" CLG HT9-1" CLG HT9-1" CLG HTSTEPSDWN10'-1" CLG HTWCSHOWERSEAT
9-1" CLG HTLAVWCLINENSEATSHOWERBUILT-INLAVA3.03/01A3
.
0
5
/
0
2A3.06/01A
3
.
0
2
/
0
2
A
3
.
0
5
/
0
2
A
3
.
0
2
/
0
2
A
3
.
0
2
/
0
1
A
3
.
0
2
/
0
1
A3.01/03A3.01/01
A
3
.
0
1
/
0
2
A3.01/01A3.03/01A3.03/02A3.03/03A3.03/03A3.04/02A3.04/02A3.04/01A3.04/01A
3
.
0
5
/
0
2SHOWER 6444444444444444444444444444444446666666664447266666667633333333277231726623 112223456222622222262
998889
9
9
9
1077
8882 22102
2
21021413
12
11 17186'-10"3'-10"21'-2"4'-8"5'-112"5'-112"4'-8"4'-2"4'-6"4'-6"4'-2"17'-4"4'-0"4'-10"8'-10"8'-1012"3'-1112"12'-10"5'-10"16'-2"1'-912"8"14'-414"4'-0"14'-4"7'-114"6'-834"10"5'-1"7'-9"5'-2"8"4'-0"4'-0"1'-0"5'-0"19'-10"7'-8"8'-5"5'-9"5'-0"2'-4"1'-10"7'-6"6'-10"15'-0"11'-0"14'-4"26'-0"7'-4"4'-4"5'-7"4'-11"3'-3"7'-012"7'-012"8'-2"14'-1"19'-3"8'-912"11'-712"10'-4"20'-514"110°4'-4"1'-0"1'-3"13'-10"6"5'-4"12'-10"5'-0"1'-10"2'-9"BARNBARN16'-0"11'-7"5'-0"2'-8"2'-4"4'-0"6'-4"4'-0"22'-8"3'-4"1'-2"5'-8"3'-0"4'-10"1'-10"6'-2"1'-10"1'-2"13'-914"20'-1034"11'-10"1'-2"3'-8"4'-9"10"2'-8"
14'-4"27'-4"18'-0"24'-7"5'-3"5'-3"1'-6"5'-0"4'-8"2'-2"19'-10"32
'
-
0
"10'-6"13'-4"9'-114"5'-4"3'-11"5'
-
0
1
4"
7'
-
7
1
4"
7'
-
8
3
4"
3'
-
7
"
6'
-
8
"
1
1
'
-
0
"
6'
-
8
"
24
'
-
4
"
23
'
-
1
1
1
4"
8'
-
4
1
2"8'-714"9'-6"13'-014"2'-0"10"11'-0"6'-6"2'-8"4'-0"1'-2"5'-8"7'-0"4'-10"3'-8"4'-0"4'-0"6'-4"2'-4"2'-8"15'-514"10"3'-3"2'-1"8"4'-4"52°1'-2"4'-712"8'-3"4'-1112"2'-1012"4'-6"
12'-2"23'-0"10'-8"2'-6"
12'-2"36'-2"3'-0"5'-912"8'-3"9'-312"23'-334"34'-2"31'-114"8'-113
4"28'-0"17'-2"10"12'-0"7'-6"5'-3"1'-2"4'-5"4'-0"1'-10"1'-10"14'-6"1'-2"6'-8"
0"
10'-6"11'-2"2'-73
4"1'-81
2"2'-1"
3'-41
2"
2'-1"
3'-
41
2"
2'-
1
"
1'
-
6
1
2"
1'-4"4'-10"10"14'-8"4'-0"8"8'-10"4'-4"4'-8"3'-8"6'-2"2'-6"10"
10"14'-0"6"6'-0"14'-0"10"45°5'
-
8
"
2'-0"6"11'-8"10"5'-6"14'-6"1'-2"10"9'-0"5'-0"3'-8"1'-4"7'-0"6"5'-8"1'-2"2'-4"10"8"2'2'-71
4"
8"6"9'-101
2"
4'
-
0
"
7'
-
6
"
10
"8"1'-1"15'-234"6"3'-
8
"
8"
5'
-
0
"
10
"
3'
-
8
"
1
1
'
-
6
"
1
0
"
4'-
0
"
7'
-
9
1
4"
6'
-
6
"
5'
-
4
"
5'
-
4
"
5'-
0
1
2"5'-10"6"7'
-
0
1
2"5'-634"52°1'-2"8'-4"1'-2"3'-10"7'-0"7'-0"7'-0"7'-0"8'-9"11'-2"25'-914"27'-114"2
2
4'
-
2
"
7'-
5
3
4"
7'
-
5
3
4"
3'-
2
"
3'-63
4"7'-5"2'-7"2'-7"15'-1134"22
'
-
3
3
4"4"8"1'-7"2'-834"2'-4"4'-2"1'-012"45'-6"79'-4"53'-312"5'-3"5'-5"2'-414"56
'
-
7
3
4"3'-4"1'-10"27'-10"13
'
-
6
"
6'
-
1
0
"
1
0
"
9'
-
1
0
"
4'
-
0
1
2"
15
'
-
1
"
1
0
"
8'
-
4
"
8'
-
4
"
1
6
'
-
8
"
4'
-
2
1
2"
20
'
-
4
"
4'
-
2
1
2"
5'
-
6
1
2"
5
0
'
-
1
1
1
2"
9'
-
9
"7'-10"7'-10"15'-8"9'-11"6'-634"4'-4"13
'
-
9
"
1
3
'
-
9
"
2
7
'
-
6
"
12
'
-
1
"
11
'
-
4
1
2"
3'-
7
"
5'
-
7
"4'-6"5'-
1
0
"
4'
-
7
"
4'
-
0
"
10
"
8'
-
0
"
3'
-
8
"
15
'
-
0
"
53
4"
1
0
'
-
7
1
4"
1'
-
0
"
1
0
"6'-412"4'-4"6'-634"9'-11"10"14'-0"10"4'-4"10"9'-9"5'-912"6'-212"6"3'-8"1'-2"36'-6"A3.01/0350
'
-
1
1
1
2"36'-6"57'-4"
55'-10"4'-214"10'-314"18'-634"13'-014"6"10"2'-6"7'-4"2'-6"52°14'-4"6"6'-10"5'-8"5'-6"4'-0"17'-0"6"2'-4"1'-6"1'-2"11'-0"18'-2"6'-4"7'-334"15'-334"2'-0"4'-0"1'-0"5'-4"6'-10"12'-8"4'-4"1'-2"10'-934"3'-2"4'-012"12'-10"34
'
-
3
"2'-312"9'-1012"5'-212"3'-1114"2'-4"3'-8"9'-414"1'-10"12'-612"1'-2"6'-11"4'-0"1'-5"7"6"12'-5"4'-0"1'-10"10"1'-0"1
0
"
8'
-
3
1
2"
11
'
-
1
3
4"
1'
-
1
0
"
2'
-
4
"
7'
-
4
"
6"
3'
-
8
"
11
'
-
6
"
10
"3'-4"4'-2"1'-2"3'-7"(19)STEPSDWN(19)STEPSDWN(19)STEPSDWN(19)STEPSDWN(19)STEPSDWN(19)STEPSDWN(19)33'-014"4'-514"10"3068 F. ARCHW/ 6'-2" S.L.3068 F. ARCHW/ 6'-2" S.L.30
6
8
F
.
A
R
C
H
W
/
6
'
-
2
"
S
.
L
.6068 C.O.6068 C.O.3068 F. ARCHW/ 6'-2" S.L.4'-0"3068 C.O.3068 C.O.ATTIC ACCESSATTIC ACCESS
3068 F. ARCH
W/ 6'-2" S.L.3068 F. ARCHW/ 6'-2" S.L.5068 F. ARCHW/ 6'-2" S.L.3068 F. ARCHW/ 6'-2" S.L.3'-0"6'-8"3'-11"7'-
1
1
4"
5'-
4
"
6"6'-1012"10"2'-0"6"5'-4"11'-8"10"42" HALF WALL 42" HALF WALL42" HALF WALL42" HALF WALLHANDRAILH
A
N
D
R
A
I
L
HANDRAILHANDRAILHANDRAILHANDRAIL HANDRAILHANDRAIL
HANDRAILHANDRAILHAND
R
A
I
L
HANDRAIL8'-11"10"R17'-4"6'-034"2'-91
4"
8'-10"4'-0"HANDRAIL
HANDRAIL
7'-
1
1
1
2"
1
3
'
-
0
"
1
0
"
5'-
2
"
2'-
6
"
5'-
8
"
6"10'-1" CLG HT11'-0"65'-7"4'-8"13'-11"ATTIC ACCESS63'-4"4'-4"6A3.05/01A3.05/013'-6"3'-6"4'-012"SCALESHEETDATEA1.041/8" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:02 AM, BUSH DESIGN & ASSOC.
10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTLAV10'-1" CLG HTWC10
'
-
1
"
C
L
G
H
T10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTWCLAV10'-1" CLG HTSHOWERSE
A
T
TUBLINEN10'-1" CLG HTTUB/SHOWERLI
N
E
N FIRE PLACE9-
1
"
C
L
G
H
T
WC48" REF.MDSINK DW
48" RANGE W/ HOOD
L
O
C
K
E
R
S
SE
A
T
W
D
SI
N
K48" REF.MD6'-10"25'-0"4'-11"4'-5"17'-1"3'-0"3'-4"6'-8"11'-0"6'-8"24'-4"24'-5"52'-1"4'-5"3'-4"17'-2"41'-214"7'-5"3'-4"10'-9"14'-11"4'-8"8'-8"8'-8"3'-4"19'-7"17'-4"
2
2
'
-
4
"A3.04/0110"2'-6"14'-6"8"7'-0"10"7'-2"1'-0"8"3'-4"8"6'-4"23'-2"4'-0"1'-6"10"1'-6"1'-8"10"14'-8"3'-6"3'-10"7'-0"7'-0"3'-4"2'-10"1'-2"3'-6"7'-0"7'-0"7'-0"7'-0"4'-6"6"3'-0"1'-2"7'-0"7'-0"22'-0"4'-934"3'-6"FLUSH HEARTH2'
-
2
"
1'
-
0
"
1
0
"
4'
-
0
"
5'
-
6
"
6"
8'
-
8
"
4'
-
0
"
4'
-
7
3
4"10'-9"1'-8"21'-0"10"3'-4"10'-2"1'-4"1'-2"6'-2"2'-4"10'-10"10"7'-93
4"6'-10"2'-41
4"8"3'-6"3'-6"1'-5"6"9'-3"5'-1"10"8"111111221713131718820201310131319159'-4"1515206'-0"1
0
'
-
7
1
4"
4'
-
0
"
1
0
"2'-10"10'-5"3'-4"23'-0"10"3'-2"1'
-
0
"
1
2
'
-
6
3
4"
1
2
'
-
0
"
1'
-
6
"
3'
-
0
"
4'
-
2
"
2'
-
9
"
1
0
"STEPSUP(19)5080 F. ARCHW/ 7'-6" S.L.5080 F. ARCHW/ 7'-6" S.L.5080 F. ARCHW/ 7'-6" S.L.5080 F. ARCHW/ 7'-6" S.L.5080 F. ARCHW/ 7'-6" S.L.GROIN VAULTFROM 8'-7" TO 10'-1" 5080 F. ARCH
W/ 7'-6" S.L.FRDGEGROIN VAULTFROM 8'-7" TO 10'-1" KS 21LAVLAVLINENBUILT-INBUILT-INFIRE PLACERAISED HEARTH6'-4"8"6'-6"7'-0"21'-2"3'-10"6'-10"5'-11
4"
17'-10"52°88'-012"6'-1"A3.05/01A3.05/01SCALESHEETDATEA2.011/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:04 AM, BUSH DESIGN & ASSOC.
WCLAV10'-1" CLG HT10
'
-
1
"
C
L
G
H
T 10'-1" CLG HT10'-1" CLG HTWCLAV10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTWC10
'
-
1
"
C
L
G
H
T10'-1" CLG HTWDWCLAV10'-1" CLG HTWHTUB/SHOWERLI
N
E
NTUBLINENSHOWERFIRE PLACE FIRE PLACE9-
1
"
C
L
G
H
T48" REF.MDSINK
48" RANGE W/ HOOD
L
O
C
K
E
R
S
SE
A
T
W
D
SI
N
K
SINK48" REF.MDREF10'-1" CLG HT48" 48" REF.MDSI
N
K
SEAT
D
W
48
"
R
A
N
G
E
W
/
H
O
O
D
P
H
A
N
T
O
M
C
A
B
.LAV8'-8"4'-0"4'-10"8'-1012"3'-1112"5'-10"4'-134"5'-6"8'-10"17'-4"8'-10"18'-8"13'-1014"18'-0"2'-3"5'-11"11'-934"1
1
'
-
0
"
6'
-
8
"
6'
-
8
"
5
4
'
-
8
"
6'
-
3
"
6'
-
3
"
1
1
'
-
0
"
6'
-
8
"
2
3
'
-
1
1
"
7'
-
6
"
7'
-
6
"
3'
-
2
"
2'
-
3
"
2
2
'
-
4
"
2
0
'
-
5
"
4
2
'
-
9
"
A
3
.
0
5
/
0
2
A
3
.
0
2
/
0
2A3.04/02A3.04/01A
3
.
0
5
/
0
215'-6"10"2'-212"1'-8"28'-0"10"13'-6"1'-10"1'-10"2'-4"17'-2"2'-034"12'-614"2'-0"3'-8"3'-6"10"4'-6"13'-6"10"8"4'-0"4'-0"10"2'-6"14'-6"1'-0"1'-0"3'-414"15'-6"3'-23
4"2'-91
2"3'-6"10"1'-2"7'-0"7'-0"22'-0"4'-934"3'-6"FLUSH HEARTH2'-4"2'-0"
K
S
21'-0"10"3'-4"1'-2"6'-2"2'-4"10'-10"10"10"9'-0"9'-0"8"2'-0"6'-0"10"7'-93
4"13'-7"4'-1034"8'-314"6'-3"FLUSH HEARTH8"
2'
-
6
"131913131111184'-334"2'-714"171820
20
20
1017131314171420 115
15
1520 20153'-6"2'-312"1'-2"5'-312"18'-0"8'-2"4'-434"2'-8"6'-114"6'-3"1'-0"2'-0"3'-734"2'-8"6'-4"6'-4"2'-8"
42"
FLUSH HEARTH
6'-0"10"1
0
"
1
7
'
-
1
0
"
4'
-
1
0
"
1
0
"
1
8
'
-
1
1
4"
4'
-
6
3
4"
10
'
-
1
"
C
L
G
H
T
20 GRILL W/ HOOD2'-6"1'-8"6"10'-034"2'-8"16'-8"1'-4"1'
-
0
"
1
2
'
-
6
3
4"2'-034"6'
-
0
"
6"
3'
-
8
"
3'
-
0
"
4'
-
2
"
2'
-
9
"
1
0
"
4'-53
4"3'-7"7080 EB ARCHW/ 7'-6" S.L.7080 EB ARCHW/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.
3080 F. ARCH
W/ 7'-6" S.L.9080 EB ARCHW/ 7'-6" S.L.3080 F. ARCH
W/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.15680 EB ARCH
W/ 7'-6" S.L.
4080 F. ARCH
W/ 7'-6" S.L.
4080 F. ARCH
W/ 7'-6" S.L.STEPSUP(19)STEPSUP(19)SINK21HANDRAILHANDRAIL1'-012"SCALESHEETDATEA2.021/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:06 AM, BUSH DESIGN & ASSOC.
10'-1" CLG HTWCWCLAV10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10
'
-
1
"
C
L
G
H
T10'-1" CLG HT10
'
-
1
"
C
L
G
H
T
W
D10'-1" CLG HTLAVBUILT-INBUILT-INTUBLINEN SHOWERFIRE PLACESI
N
K
48" HALF WALL48" HALF WALL
W/ ARCH ABOVE48" REF.SINK MDDW TD42" RANGE W/ HOOD 48" REF.SI
N
K
SINK MDDW TD48" RANGE W/ HOOD SEATLAV 4'-134"5'-6"8'-10"4'-8"4'-8"3'-8"2'-10"4'-8"4'-8"2'-2"6'-4"9'-4"10'-414"7'-4"4'-4"13'-1018'-0"26'-0"14'-4"27'-4"11'-934"5'-7"4'-11"3'-3"7'-012"7'-012"8'-2"14'-1"19'-3"8'-912"8'-912"2'-10"5'-0"17'-714"8'-5"4'-10"1'-8"1'-8"16'-0"6'-10"8'-934"3'-2"3'-2"3'-6"1'-4"1'-4"FLUSH HEARTH
25'-514"12'-7"4'-4"8'-3"10'-134"5'
-
0
"
7'
-
7
"
2
3
'
-
1
1
"
2
1
'
-
5
1
2"
9'
-
6
"
8'
-
7
1
2"
3'
-
4
"2'-10"1'-0"9'-1"19'-012"20°70°2'-81
2"5'-0"3'-514"1'-10"10'-4"2'-1114"6'
-
1
0
"
6'
-
1
0
"
6'
-
8
"
1
1
'
-
0
"
6'
-
3
"
6'
-
3
"
1
1
'
-
0
"
1
3
'
-
8
"
2
3
'
-
1
1
"
2
3
'
-
1
1
"
37'-8"
A
3
.
0
5
/
0
2A3.06/01A
3
.
0
2
/
0
2A3.06/01A3.03/01A3.04/02A3.04/021'-0"12'-2"2'-0"4'-514"2'-114"15'-6"10"2'-212"1'-8"2'-034"12'-614"4'-4"1'-4"2'-4"10"21'-4"8"6'-10"7'-2"4'-6"12'-10"6"2'-0"3'-8"3'-6"10"4'-6"13'-6"1'-0"1'-0"3'-414"15'-6"1'-2"1'-2"
14'-0"11'-6"10'-2"3'-4"3'-10"6"7'-0"6"3'-8"2'-4"10'-113
4"
3'-23
4"2'-91
2"3'-6"10"
1'
-
0
"
8"3080 F. ARCH184'-334"2'-714"20
20
20131317121616111019 1417146'-8"1812'-1"5'-10"1'-4"171516191920
2219191919 19151515154'
-
1
0
"
1
0
"
1
8
'
-
1
1
4"
4'
-
6
3
4"
8'
-
1
1
"GRILL W/ HOODG
R
I
L
L
W
/
H
O
O
D
6'-7"3'-7"3'-7"10"5'-7"7'-10"12'-9"10"4'-4"4'-0"8"4'-4"8'-2"1'-2"3'-4"W/ 7'-6" S.L.118080 F. ARCH
W/ 7'-6" S.L.7680 F. ARCHW/ 7'-6" S.L.STEPSUP(19)STEPSUP(19)47'-1"3'-5"K.S.
HANDRAIL HANDRAIL2'-2"4'-1114"1'-10"FIRE PLACE3'-6"1'-0"FIRE PLACE8'-8"3'-10"2'-5"6'-2"SCALESHEETDATEA2.031/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:06 AM, BUSH DESIGN & ASSOC.
WCLAV10'-1" CLG HT10'-1" CLG HT10
'
-
1
"
C
L
G
H
T
W D10'-1" CLG HTWC10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTWHSHOWER
SEAT48" REF.FIRE PLACESINK
DW
KS
SINK48" HALF WALLOPEN TO ABOVE48" REF.SINK
DW TD
SINK
48" RANGE W/ HOOD
LAVLAVTUBMD2'-10"5'-0"16'-0"12'-7"4'-4"8'-3"8'-0"1'-10"6'-10"3'-8"4'-8"2'-2"31'-10"10'-134"3'-9"10'-214"6'-114"20'-012"1'-2"13'-10"2'-2"9'-6"7'-33
4"3'-4"4'-0"2'-8"4'-2"
2'-4"
6"
19'-21
2"
111
4"9'-23
4"1'-2"2'-10"2'-103
4"2'-8"
8'-6"10"4'-5"4'-5"8"
1
0
"
6'
-
0
"
1
0
"
1
6
'
-
5
"
6'
-
3
"
8'
-
9
"
3'
-
7
"
3'
-
7
"
8'-012"10"
2'-9"1'-73
4"
5'-0"7'-7"7'-7"3'-8"6'-8"
1
1
'
-
0
"
6'
-
8
"
23'-11"21'-512"9'-6"8'-712"3'-4"2'-10"1'-0"9'-1"19'-012"20°11'-0"6'-3"6'-3"23'-11"A3.05/02A3.02/02
A
3
.
0
2
/
0
2A3.03/025'-71
2"
38°2'-8"11"FL
U
S
H
H
E
A
R
T
H
31'-114"24'-412"1'-0"20201911
1717131313131399141820
20
1
0
"
2'
-
9
"2021ABOVE22222223
191919GRILL W/ HOOD
10"14'-9"6'-7"5'-0"10"4'-5"4'-5"8"7'-1"9'-1"2'-0"6"3'-2"6"2'-2"4'-2"3'-10"10"5'
-
1
0
1
2"4'-0"2'-012"2'-0"2'-0"6"3'-4"6"3'-6"6"6'-2"10"5'-3"3'-5"4080 F. ARCHW/ 7'-6" S.L.4080 F. ARCH
W/ 7'-6" S.L.13080 EB ARCHW/ 7'-6" S.L.13080 EB ARCH
W/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.STEPSUP(19)4'-8"3'-5"5'-5"5'-3"6'-8"1'-10"10"18'-6"14'-0"10"10"6'-10"1'-10"FL
U
S
H
H
E
A
R
T
H
H
A
N
D
R
A
I
L 2'-0"111
4"23
3'
-
0
"
3'
-
0
"4'-4"4'-0"6"
1'-6"1'-5"4'
-
2
"2'-8"FIRE PLACESCALESHEETDATEA2.041/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:08 AM, BUSH DESIGN & ASSOC.
10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTW
WCLAV10'-1" CLG HTWDWC
LAV 10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTSLOPED CLG10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTLAVLAVWC10'-1" CLG HT10'-1" CLG HTWCLAV10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTWD10'-1" CLG HTWC10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTTUBWHWH10
'
-
1
"
C
L
G
H
T
TUBSHOWER SEATSHOWER SEAT48" REF.LOCKERS
LOCKERSBUILT-INBUILT-INFIRE PLACE42" FIRE PLACESINKDW KS
SINKSINK
48" HALF
W
A
L
L
48"
H
A
L
F
W
A
L
L10'-1" CLG HT48" REF.SINKSINKDW TD SINK48" RANGE W/ HOOD
DW48" RANGE W/ HOOD48" REF.MD SINKLAVLAVGRILL W/ HOOD
BUILT-INSEATSHOWERTUBMD
3'-0"3'-8"4'-8"2'-2"3'-9"10'-214"2'-412"13'-314"2'-712"6'-114"20'-012"18'-314"3'-914"2'-634"5'-612"2'-634"5'
-612"
2
'
-
6
3
4"
5'
-
6
1
2"
2'-
6
3
4"
10'
-
3
"
10'-41
4"3'-0"11'-2"11'-0"11'-0"6'-8"
53'-21
2"
3'-0"
3'-0"
5'-7"
8"
5'-51
4"
3'
-
1
1
4"
4'
-
1
3
4"2'-1014"10'-134"3'-1"10"9'-012"6"6'-0"1'-2"21'-4"1'-2"4'-0"6"4'-0"5'-8"8'-4"9'-0"10"17'-93
4"4'-8"10"3'-4"5'-8"
4'-51
2"2'-6"
10"3'-8"7'-2"3'-0"3'-4"10"3'-6"13'-0"10"5'-10"6"7'-03
4"3'-0"6'-111
2"
17'-0"
1'-2"13'-10"2'-2"9'-6"7'-334"3'-4"4'-0"2'-8"4'-2"2'-4"6"19'-212"1114"9'-234"1'-2"2'-10"2'-1034"2'-8"22'-8
"
10"6'-0"10"16'-5"6'-3"8'-9"11'-0"6'-8"6'-8"54'-8"A3.02/02
A
3
.
0
1
/
0
2
A3.01/01A3.01/01A3.03/02A3.03/03A3.03/033'-0"6'-0"13'-83
4"10"3'-4"6"9'-0"6'-4"4'-4"1'-10"6"3'-4"4'-0"8'-111
4"
1'-2"
17'-6"FIXED LAV5'-712"38°2'-8"11"FLUSH HEARTH 31'-114"7'-812"3'-112"10"2'-0"5'-10"3'-4"22'-4"1'-4"6"13'-4"5'-8"6"20'-8"1'-4"2'-10"6"5'-4"2'-2"2'-2"23'-0"
10"4'-51
2"8'-03
4"4'-111
2"8"
7'-71
2"10"17'-2"10"
8'-10"
16'-73
4"6'-5"28'-0"24'-412"12'-434"1911113'-0"15'-2"
2'-6"7'-2"5'-6"1717171717171313131313999141818181'-8"1312161317111820
14158'-4"111114141410"2'-9"
1
6
'
-
3
"
3'
-
8
"
5'
-
8
"1'-214"3'-9"3'-012"1'-2"1112021ABOVE19191
9
1919191920
202014'-9"8"7'-1"9'-1"2'-0"6"3'-2"6"2'-2"4'-2"3'-10"10"7'-812"10'-412"1'-2"15'-11"6'-8"10"2'-10"1'-6"5'-1012"10"4'-0"2'-012"2'-0"2'-0"6"3'-4"6"3'-6"6"6'-2"10"13'-4"10'-0"3'-6"2'-8"1'2'-4"13'-4"10"3'-10"RAISED HEARTH
RAISED HEARTH
4080 F. ARCHW/ 7'-6" S.L.13080 EB ARCHW/ 7'-6" S.L.13080 EB ARCHW/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.3080 F. ARCHW/ 7'-6" S.L.3080 F. ARCH
W/ 7'-6" S.L.6880 EB ARCHW/ 7'-6" S.L.6880 EB ARCHW/ 7'-6" S.L.7080 EB ARCH
W/ 7'-6" S.L.8980 F. ARCHW/ 7'-6" S.L.6'-6"6'-91
2"4'-2"STEPSUP(19)STEPSUP(19)STEPSUP(19)3080 F. ARCHW/ 7'-6" S.L.8"5080 F. ARCH
W/ 7'-6" S.L.4"212121K.S.4'-8"13'-11"10"18'-6"14'-0"10"1'-2"2'-2"1'-0"FLUSH HEARTH
FLUSH HEARTHHANDRAIL
HANDRAIL241114"2'-0"233'-0"3'-0"4'-4"4'-0"6"1'-6"
8'-101
2"2'-9"1'-11
2"1'-5"4'-2"2'-8"4'-1012"FIRE PLACE
FIRE PLACE
2'-012"SCALESHEETDATEA2.051/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:09 AM, BUSH DESIGN & ASSOC.
10'-1" CLG HT10
'
-
1
"
C
L
G
H
T10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HT10'-1" CLG HTWC10'-1" CLG HTW
D
WCLAV10'-1" CLG HT10'-1" CLG HT10
'
-
1
"
C
L
G
H
T LAVWH10
'
-
1
"
C
L
G
H
T
TUB48" REF.LOCKERS
42" FIRE PLACE48" HALF
W
A
L
L
48"
H
A
L
F
W
A
L
L
D
W
SI
N
K
D
WSINK 48
"
R
A
N
G
E
W
/
H
O
O
D
M
D
BUILT-INSEATSHOWER 17'-2"28'-0"17'-2"10"1'-11"6'-512"3'-912"3'-0"3'-0"
3'-0"
5'-7"
8"
5'-51
4"
3'
-
1
1
4"
4'
-
1
3
4"
8'
-
4
"
8'
-
4
"
4'
-
2
1
2"
5'
-
6
1
2"
3
3
'
-
8
"2'-1014"4'-4"7'-10"7'-10"4'-4"6'-10"3'-1"15'-8"9'-11"6'-634"10"4'-4"1'-0"5'-0"3'-8"10"2'-414"4'-212"1'-2"4'-9"6'-4"2'-10"8"2'-10"4'-11"2'-1"2'-8"1'-8"10'-134"3'-1"10"9'-012"6"6'-0"10"17'-93
4"4'-8"
4"
10"5'-10"6"7'-03
4"
17'-0"
6'
-
7
1
2"
5'
-
9
1
2"
5'
-
6
1
2"
1
0
"
1
1
'
-
9
"
8"
1
7
'
-
8
"
6"
1'
-
4
"
5'
-
1
0
"
1
2
'
-
8
"
1
6
'
-
3
"
2'
-
2
"
1
0
"
22'-8"10"6'-0"10"
1
2
'
-
5
"
1
1
'
-
4
1
2"
3
1
'
-
1
"
6'-8"6'-8"11'-0"6'-8"
3
1
'
-
1
"
2
3
'
-
9
1
2"
54'-8"A3.02/01 A3.05/02
A
3
.
0
2
/
0
1
A3.01/03A3.01/03A
3
.
0
1
/
0
2
3'-0"6'-0"13'-83
4"10"2'-4"5'-8"4'-1012"6"16'-10"4'-4"1'-10"1'-4"LAV31'-114"10"4'-51
2"8'-03
4"4'-111
2"8"
2'
-
8
"
3'
-
1
0
1
2"
3'
-
1
0
1
2"
2'
-
4
"
1
1
'
-
1
0
1
2"24'-412"191717181820
1111141414141410"2'-9"
1
6
'
-
3
"
3'
-
8
"
5'
-
8
"
4'
-
3
"
2'
-
8
"
1'
-
1
1
"
1
3
'
-
5
"
1
0
"1'-214"3'-9"3'-012"1'-2"11121310131
2019
19191920
15
20 20
3080 F. ARCHW/ 7'-6" S.L.STEPSUP(19)4"5080 F. ARCHW/ 7'-6" S.L.5080 F. ARCHW/ 7'-6" S.L.71
8
0
F
.
A
R
C
H
W
/
7
'
-
6
"
S
.
L
.5080 F. ARCHW/ 7'-6" S.L.71
8
0
F
.
A
R
C
H
W
/
7
'
-
6
"
S
.
L
.
21
36'-6"FLUSH HEARTHHANDRAIL233'-0"3'-0"
2'-9"1'-11
2"1'-5"3'
-
2
"
1
01
2"
4'
-
6
1
2"1'-7"3'-5"4'-1012"3'-0"2'-012"SCALESHEETDATEA2.061/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:11 AM, BUSH DESIGN & ASSOC.
LAVWCWCLAVT
U
B
/
S
H
O
W
E
R
BUILT-IN9-1" CLG HT9'-1" CLG HT9'-1" CLG HT9-1" CLG HTLINENLINENTUB/SHOWER9-1" CLG HT9-1" CLG HT9-1" CLG HTSTEPSDWNWCSHOWERSEAT A3.04/01644444266112223452226'-10"3'-10"21'-2"4'-8"5'-112"5'-112"4'-8"4'-2"4'-6"4'-6"4'-2"17'-4"1'-0"5'-0"19'-10"7'-8"8'-5"5'-9"5'-0"24'-7"1'-2"8'-4"1'-2"3'-10"7'-0"7'-0"7'-0"7'-0"8'-9"11'-2"27'-114"10"2'-6"7'-4"2'-6"
1'-0"5'-4"6'-10"12'-8"4'-4"1'-2"10'-934"3'-2"4
'
-
0
1
2"(19)5068 F. ARCHW/ 6'-2" S.L.3'-0"6'-8"3'-11"7'
-
1
1
4"
5'
-
4
"
6"6'-1012"10"2'-0"6"5'-4"42" HALF WALL1
0
"
5'
-
2
"
2'
-
6
"11'-0"6A3.05/01A3.05/01A3.05/013'-6"4'-012"SCALESHEETDATEA2.071/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:12 AM, BUSH DESIGN & ASSOC.
10'-1" CLG HT10'-1" CLG HTWCWCLAV9-1" CLG HT9'-1" CLG HTWCWCLAVLAVLAVT
U
B
/
S
H
O
W
E
R
T
U
B
/
S
H
O
W
E
R9-1" CLG HTVANITYBUILT-IN
SHOWER SEAT9'-1" CLG HT9'-1" CLG HTLAVTUBWCTUB/SHOWER LINENLINENTUB/SHOWER9'-1" CLG HT9-1" CLG HT9-1" CLG HT9-1" CLG HT9-1" CLG HT10'-1" CLG HTSHOWERSEAT
LAVA
3
.
0
5
/
0
2
A
3
.
0
2
/
0
2A3.04/02A3.04/01A
3
.
0
5
/
0
2 4444444446666763317626226222
10
84'-6"4'-6"4'-2"17'-4"4'-0"4'-10"8'-10"8'-1012"3'-1112"12'-10"5'-10"16'-2"1'-912"8"14'-414"4'-0"14'-4"7'-114"6'-834"10"5'-1"7'-9"5'-2"8"4'-0"4'-0"1'-0"5'-0"2'-4"1'-10"18'-0"
1
1
'
-
0
"
6'
-
8
"
2
4
'
-
4
"8'-714"28'-0"17'-2"10"12'-0"7'-6"27'-114"2
2
4'
-
2
"
7'
-
5
3
4"
7'
-
5
3
4"
3'
-
2
"
3'-63
4"7'-5"2'-7"2'-7"15'-1134"2
2
'
-
3
3
4"4"8"1'-7"2'-834"2'-4"4'-2"1'-012"45'-6"4'-214"10'-314"18'-634"13'-01
4"6"10"2'-6"7'-4"52°14'-4"6"6'-10"5'-8"5'-6"4'-0"
17'-0"
6"
2'-4"1'-6"1'-2"11'-0"18'-2"6'-4"7'-334"15'-33
4"
2'-0"
4'-0"1'-0"5'-4"6'-10"4'-4"1'-2"10'-934"3'-2"4
'
-
0
1
2"
3
4
'
-
3
"2'-312"9'-1012"5'-212"3'-1114"2'-4"3'-8"9'-414"1'-10"12'-612"STEPSDWN(19)STEPSDWN(19)33'-014"4'-514"10"3068 F. ARCHW/ 6'-2" S.L.3068 F. ARCH
W/ 6'-2" S.L.3'-0"6'-8"3'-11"7'
-
1
1
4"
5'
-
4
"6'-1012"10"2'-0"6"5'-4"11'-8"10"42" HALF WALLHANDRAILHANDRAIL HANDRAIL
7'
-
1
1
1
2"
1
3
'
-
0
"
1
0
"
5'
-
2
"
2'
-
6
"
5'
-
8
"
6"10'-1" CLG HT11'-0"63'-6"SCALESHEETDATEA2.081/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:14 AM, BUSH DESIGN & ASSOC.
9-1" CLG HT9-1" CLG HTWC9-1" CLG HT9-1" CLG HT9-1" CLG HTWCLAVLAV9-1" CLG HTLAVWCLINEN9-1" CLG HT9-1" CLG HTSHOWERTUB/SHOWER SHOWERSEATA3.03/01A
3
.
0
5
/
0
2A3.06/01A
3
.
0
2
/
0
2A3.03/01A3.04/02A3.04/02SHOWER444444666333772222629917 187'-6"6'-10"15'-0"11'-0"
14'-4"26'-0"7'-4"4'-4"5'-7"4'-11"3'-3"7'-012"7'-012"8'-2"14'-1"19'-3"8'-912"11'-712"10'-4"20'-514"11
0
°
4'-4"1'-0"1'-3"13'-10"6"5'-4"12'-10"5'-0"1'-10"2'-9"BARNBARN16'-0"11'-7"
5'-0"2'-8"2'-4"
4'-0"6'-4"4'-0"22'-8"3'-4"1'-2"5'-8"3'-0"4'-10"1'-10"6'-2"1'-10"1'-2"13'-91
4"20'-103
4"11'-10"1'-2"3'-8"4'-9"10"2'-8"
14'-4"
27'-4"9'-15'-4"3'-11"5'
-
0
1
4"
7'
-
7
1
4"2
3
'
-
1
1
1
4"
8'
-
4
1
2"
79'-4"53'-312"3'-4"1'-10"27'-10"4'-214"10'-314"18'-634"1'-2"6'-11"4'-0"1'-5"7"6"12'-5"4'-0"1'-10"10"1'-0"STEPSDWN(19)33'-014"3068 F. ARCHW/ 6'-2" S.L.42" HALF WALL
HANDRAILHANDRAIL
HANDRAIL
8'-11"10"65'-7"4'-8"ATTIC ACCESS3'-4"
4'-4"6SCALESHEETDATEA2.091/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:15 AM, BUSH DESIGN & ASSOC.
10'-1" CLG HTWCLAV9'-1" CL
G
H
T
9'-1" CLG HT9-
1
"
C
L
G
H
T
9'-
1
"
C
L
G
H
T
9-1" CLG HT9-
1
"
C
L
G
H
TLAVWC T
U
B
/
S
H
O
W
E
R
T
U
B
/
S
H
O
W
E
ROPEN TO BELOWHAND RAIL9-1" CLG HTLAVWCLINENSEATSHOWERBUILT-INA3.05/02A3.02/02
A
3
.
0
2
/
0
2A3.03/02A3.03/03A3.05/02
44444666444722998889 9 9
9
1077
810'-4"16'-0"2'-8"5'-3"5'-3"1'-6"5'-0"4'-8"2'-2"19'-10"3
2
'
-
0
"10'-6"13'-4"9'-114"5'-4"3'-11"5'-014"7'-714"7'-834"3'-7"
6'
-
8
"
1
1
'
-
0
"
6'
-
8
"
2
4
'
-
4
"
23'-1114"8'-412"8'-714"9'-6"13'-014"2'-0"10"11'-0"6'-6"2'-8"4'-0"1'-2"5'-8"7'-0"4'-10"3'-8"4'-0"4'-0"6'-4"2'-4"2'-8"15'-514"10"3'-3"2'-1"8"4'-4"52°1'-2"
4'-6"
12'-2"23'-0"10'-8"2'-6"
12'-2"36'-2"3'-0"31'-114"8'-113
4"28'-0"10"8"2'2'-71
4"
8"6"9'-101
2"
4'
-
0
"
7'
-
6
"
1
0
"8"1'-1"15'-234"6"3'
-
8
"
8"
5'
-
0
"
1
0
"
3'
-
8
"
1
1
'
-
6
"
1
0
"
4'
-
0
"
7'
-
9
1
4"
6'
-
6
"
5'
-
4
"
5'
-
4
"
5'
-
0
1
2"5'-10"6"7'
-
0
1
2"5'-634"52°2'-7"5'-3"5'-5"2'-414"56'-734"
55'-10"12'-10"10"8'-312"
1
1
'
-
1
3
4"
1'
-
1
0
"
2'
-
4
"
7'
-
4
"
6"
3'
-
8
"
1
1
'
-
6
"
1
0
"3'-4"3'-7"STEPSDWN(19)3068 F. ARCHW/ 6'-2" S.L.30
6
8
F
.
A
R
C
H
W
/
6
'
-
2
"
S
.
L
.ATTIC ACCESS3068 F. ARCH
W/ 6'-2" S.L.42" HALF WALLHANDRAIL10"8'-10"4'-0"13'-11"SCALESHEETDATEA2.101/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:16 AM, BUSH DESIGN & ASSOC.
9'-1" CLG HTLAVLAVWCWC9-1" CLG HT9'-1" CLG HT9'-1" CLG HT9-1" CLG HT9-1" CLG HT9-1" CLG HTWCLAV9-1" CLG HTWCLAV9'-1" CLG HT9'-1" CLG HT9-1" CLG HT9'-1" CLG HT 9-1" CLG HT9-1" CLG HTLAVWC
B
U
I
L
T
-
I
N
TUB/SHOWER
TUB/SHOWERBUILT-INSHOWERSEATBUILT-INSHELVES
TUB/SHOWERTUB/SHOWER 9-1" CLG HTLAVWCLINENSEATSHOWERBUILT-INA3.02/02
A3.01/01
A
3
.
0
1
/
0
2
A3.01/01A3.03/02A3.03/03A3.03/034444444444446666664447233332888108
88210
21413
12
11 1'-6"5'-0"4'-8"2'-2"19'-10"32'-0"13'-4"11'-0"6'-8"8'-714"9'-6"13'-014"11'-0"6'-6"2'-8"4'-0"1'-2"5'-8"7'-0"4'-10"3'-8"4'-0"4'-0"6'-4"2'-4"2'-8"8"4'-4"52°1'-2"4'-712"8'-3"4'-1112"2'-1012"4'-6"
12'-2"23'-0"10'-8"2'-6"
12'-2"36'-2"3'-0"5'-912"8'-3"9'-312"23'-334"34'-2"31'-114"8'-113
4"28'-0"5'-3"1'-2"4'-5"4'-0"1'-10"1'-10"14'-6"1'-2"6'-8"
0"
10'-6"11'-2"2'-73
4"1'-81
2"2'-1"
3'-41
2"
2'-1"
3'-
41
2"
2'-
1
"
1'
-
6
1
2"
1'-4"4'-10"10"14'-8"4'-0"8"8'-10"4'-4"4'-8"3'-8"6'-2"2'-6"10"
10"14'-0"6"6'-0"14'-0"10"45°5'-8"2'-0"6"11'-8"10"5'-6"14'-6"1'-2"10"9'-0"5'-0"3'-8"1'-4"7'-0"6"5'-8"1'-2"2'-4"8"6"9'-1012"4'-0"7'-6"10"8"1'-1"15'-234"6"3'-8"8"5'-0"10"3'-8"11'-6"10"4'-0"7'-914"6'-6"5'-4"5'-4"5'-012"5'-10"6"7'
-
0
1
2"5'-634"52°25'-914"1
3
'
-
6
"
6'
-
1
0
"
4'
-
2
1
2"
2
0
'
-
4
"
5
0
'
-
1
1
26'-412"4'-4"36'-6"57'-4"
55'-10"12'-10"1'-10"2'-4"7'-4"6"3'-8"11'-6"10"3'-4"4'-2"1'-2"3'-7"STEPSDWN(19)STEPSDWN(19)3068 F. ARCHW/ 6'-2" S.L.6068 C.O.6068 C.O.3068 F. ARCHW/ 6'-2" S.L.4'-0"ATTIC ACCESSATTIC ACCESS
3068 F. ARCHW/ 6'-2" S.L.42" HALF WALLHANDRAILHANDRAILHANDRAILHANDRAILHANDR
A
I
L R17'-4"6'-034"2'-91
4"
HANDRAIL13'-11"SCALESHEETDATEA2.111/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:16 AM, BUSH DESIGN & ASSOC.
WCLAV9'-1" CLG HT9-1" CLG HT9'-1" CLG HTWCLAV9-
1
"
C
L
G
H
T
9-
1
"
C
L
G
H
TWCLAV9-1" CLG HT 9-1" CLG HTB
U
I
L
T
-
I
N
TUB/SHOWERTUB/SHOWERTUB/SHOWER A3.05/02A3.02/01
A
3
.
0
2
/
0
1
A3.01/03A
3
.
0
1
/
0
244 4444466638108
2 22102
2
2
6'-8"8'-714"9'-6"2'-6"34'-2"31'-114"10"
10"
10"25'-914"1
3
'
-
6
"
6'
-
1
0
"
1
0
"
9'
-
1
0
"
4'
-
0
1
2"
1
5
'
-
1
"
1
0
"
8'
-
4
"
8'
-
4
"
1
6
'
-
8
"
4'
-
2
1
2"
2
0
'
-
4
"
4'
-
2
1
2"
5'
-
6
1
2"
5
0
'
-
1
1
1
2"
9'
-
9
"7'-10"7'-10"15'-8"9'-11"6'-634"4'-4"1
3
'
-
9
"
1
3
'
-
9
"
2
7
'
-
6
"
1
2
'
-
1
"
1
1
'
-
4
1
2"
3'
-
7
"
5'
-
7
"4'-6"5'
-
1
0
"
4'
-
7
"
4'
-
0
"
1
0
"
8'
-
0
"
3'
-
8
"
1
5
'
-
0
"
53
4"
1
0
'
-
7
1
4"
1'
-
0
"
1
0
"6'-412"4'-4"6'-634"9'-11"10"14'-0"10"4'-4"10"9'-9"5'-912"6'-212"6"3'-8"1'-2"36'-6"A3.01/035
0
'
-
1
1
1
2"36'-6"12'-10"34'-3"10"STEPSDWN(19)3068 C.O.3068 C.O.H
A
N
D
R
A
I
L
HANDRAILSCALESHEETDATEA2.121/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:17 AM, BUSH DESIGN & ASSOC.
STONET.P.T.P.T.D.T.P.T.P.T.D.T.S.T.S.A4.01/05A4.03/09A4.03/09A4.03/09A4.03/09A4.02/04A4.02/04A4.02/08A4.02/089'-1"1'-4"10'-1"TERRA COTTA TILE ROOFSTONEA4.03/08A4.03/08A4.03/01STONESTONESTONEA4.01/05T.P.T.P.T.D.T.S.T.P.T.P.T.D.T.S.STONESTUCCOA4.02/05A4.03/09STONESTONESTONESTONEA4.02/09A4.02/069'-1"1'-4"10'-1"A4.02/05A4.03/09A4.02/10TERRA COTTA TILE ROOFTERRA COTTA TILE ROOFA4.02/10A4.01/04A4.01/03A4.01/1110'-1"T.P.T.P.T.D.T.S.T.P.T.P.T.D.T.S.STONESTONEA4.02/05A4.01/06A4.01/11A4.01/03STONEA4.02/02STONEA4.02/049'-1"1'-4"10'-1"A4.02/05A4.02/05TERRA COTTA TILE ROOFTERRA COTTA TILE ROOFA4.02/10STONEA4.03/02A4.01/03STONEA4.03/121'-4"T.P.T.P.21'-10"SCALESHEETDATEA3.011/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:18 AM, BUSH DESIGN & ASSOC.
T.S.T.P.T.D.T.P.T.S.T.P.T.D.T.P.T.S.T.P.T.D.T.P.STONEA4.01/06STONEA4.02/06A4.01/11A4.02/10A4.01/03A4.01/10A4.01/11STUCCOSTONESTONESTONEA4.03/09A4.03/09STONE9'-1"1'-4"10'-1"
9'-1"1'-4"10'-1"A4.02/05A4.02/05A4.02/05A4.02/10TERRA COTTA TILE ROOFTERRA COTTA TILE ROOFA4.02/09A4.03/07A4.03/07A4.01/03A4.01/03T.S.T.P.T.D.T.P.T.S.T.P.T.D.T.P.STONEA4.01/06A4.01/03STONESTONEA4.03/09A4.03/09A4.03/09A4.03/09STONEA4.02/03A4.02/04A4.01/01A4.01/019'-1"1'-4"10'-1"
9'-1"1'-4"10'-1"A4.02/05TERRA COTTA TILE ROOFTERRA COTTA TILE ROOFSTONEA4.03/07A4.03/07A4.03/07STONESCALESHEETDATEA3.021/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:20 AM, BUSH DESIGN & ASSOC.
T.P.T.P.T.D.T.D.T.P.T.P.T.P.T.S.T.S.COURTYARD WALLSTUCCOSTUCCOT.P.T.P.A4.01/06A4.01/02A4.02/02A4.03/09A4.03/09A4.03/09STONESTONESTONESTONEA4.02/03A4.02/04A4.03/129'-1"1'-4"10'-1"T.P.A4.02/09A4.02/10STONETERRA COTTA TILE ROOFA4.02/09A4.01/04GAS LAMPSTONEA4.03/038'-0"21STONEA4.02/10A4.02/05A4.03/09A4.02/08T.P.T.P.T.P.T.D.T.P.T.P.T.S.COURTYARD WALLA4.01/08A4.01/02A4.03/09A4.03/09A4.03/09STONESTONESTONEA4.03/12A4.03/129'-1"1'-4"10'-1"T.P.T.P.A4.02/10A4.02/10STONESTONEA4.03/09T.P.T.P.T.P.T.P.T.D.T.D.T.P.T.P.T.D.T.P.T.P.T.S.T.S.A4.01/06A4.01/03STONESTONESTONEA4.01/11A4.03/09STONESTONEA4.02/089'-1"1'-4"10'-1"A4.02/08A4.02/10STONESTONETERRA COTTA TILE ROOFA4.02/09A4.02/09A4.03/024'-0"A4.02/05A4.03/11SCALESHEETDATEA3.031/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:21 AM, BUSH DESIGN & ASSOC.
T.P.T.P.T.P.T.S.T.D.T.S.T.D.T.P.T.P.T.P.STUCCOA4.01/06STUCCOA4.01/06A4.01/10A4.03/09STONESTONESTONESTONESTONESTONESTUCCOA4.03/12A4.03/12A4.02/08A4.01/07A4.02/09A4.02/10A4.02/10A4.01/01CLAY TILE ROOFA4.01/05GAS LAMPA4.03/04A4.03/05A4.02/09A4.02/08STUCCOSTONEA4.01/05A4.02/05A4.02/05T.P.T.P.T.D.17'-3"10'-1"1'-4"9'-1"T.P.T.S.T.D.T.P.T.P.T.P.T.P.T.S.T.D.T.P.T.S.T.D.STUCCOSTUCCOSTONEA4.01/03A4.03/09A4.03/09A4.03/09STONESTONESTONESTONESTONESTONESTUCCOSTONEA4.02/08A4.02/08A4.01/01STONEA4.01/03A4.01/03A4.03/11A4.03/09A4.02/09CLAY TILE ROOFCLAY TILE ROOF9'-1"1'-4"10'-1"SCALESHEETDATEA3.041/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:23 AM, BUSH DESIGN & ASSOC.
T.P.T.P.STUCCOSTUCCOSTONESTUCCOSTUCCOSTONESTONESTONEA4.01/02A4.01/02A4.03/09A4.03/09A4.02/11A4.01/07A4.01/08A4.01/06T.S.T.P.T.P.T.S.T.P.9'-1"1'-4"10'-1"
9'-1"1'-4"10'-1"A4.01/03A4.01/03GAS LAMPA4.02/10A4.02/10A4.03/08A4.03/08STONEA4.02/05STUCCOCLAY TILE ROOFCLAY TILE ROOFT.P.STUCCOSTUCCOSTUCCOSTUCCOSTUCCOSTONEA4.03/09A4.03/09A4.03/09STUCCOSCUPPERT.D.STONESTONESTUCCOSTONET.P.T.D.T.S.T.P.9'-1"T.S.T.P.T.P.10'-1"1'-4"
1'-4"10'-1"
9'-1"2'-0"A4.02/11TERRA COTTA TILE ROOFTERRA COTTA TILE ROOFA4.01/03A4.01/03A4.01/03A4.03/06A4.03/06A4.03/06A4.03/06A4.03/06A4.02/04A4.03/10A4.02/05A4.02/06T.P.T.S.T.P.T.P.1'-4"10'-1"
10'-1"1'-4"9'-1"4'-0"SCALESHEETDATEA3.051/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:25 AM, BUSH DESIGN & ASSOC.
T.P.T.P.A4.03/09A4.03/09STONESTONESTONEA4.02/08A4.01/07T.D.T.P.T.P.T.D.T.S.9'-1"1'-4"10'-1"
9'-1"1'-4"10'-1"STONESTONESTUCCOA4.01/01STONETERRA COTTA TILE ROOFTERRA COTTA TILE ROOFA4.01/06A4.01/03A4.01/03SCALESHEETDATEA3.061/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:27 AM, BUSH DESIGN & ASSOC.
ELEV.12REF.RAFTER - REF. STRUCT.PLATE HT.1x4 FASCIA6" HALF RND.MTL. GUTTER2x4 SUB-FASCIACAST STONEA4.01/09STONE VENEERDRIP EDGEBIRD STOPTILE ROOFINGDECKING &BLDR PAPERPACKEDMORTARPACKEDMORTARBATT INSUL. -REF. I.E.C.C.GYP. BOARDCEILING JOIST -REF. STRUCT.REF: A4.01/08ELEVATIONREF: A4.01/09,10123"x4" CEDAR RAFTER TAIL1/4" CEDART&GGYP. BOARDBATT INSUL. -REF. I.E.C.C.CEILING JOIST -REF. STRUCT.PLATE HT.RAFTER - REF. STRUCT.ELEV.12REF.DECKING &BLDR PAPERSTONE VENEER1x4 FASCIA2x4 SUB-FASCIA6" HALF ROUNDGUTTERDRIP EDGEBIRD STOPTILE ROOFINGPLUMB CUTFACE OF 2X6PLATE HT.BATT INSUL.- REF. I.E.C.C.CEILING JOIST- REF. STRUCT.GYP. BOARDGUTTER6" HALF RNDELEV.12REF.1X6CEDART>ILE ROOFINGBIRD STOPDRIP EDGESTONE VENEERRAFTER - REF. STRUCT.2.5" STONE2.5" STONE1/2" SOFFIT1x4 FASCIA6" HALF RND.MTL. GUTTER2x4 SUB-FASCIAMOTORMOTORRAFTER
-
REF
.
STRUCT
.PLATE HT.PACKEDMORTARCUT CLAY TILE2x4 SUB-FASCIASTUCCOCEILING JOIST -REF. STRUCT.GYP. BOARDTREATED 2x4 BLOCKBATT INSUL. -REF. I.E.C.C.ELEV.12REF.DECKING &BLDR PAPERTILE ROOFINGBIRD STOPDRIP EDGE6" HALF RND.MTL. GUTTER1x4 FASCIAPACKEDMORTAR1"2"412"CAST STONE CAP6"x6"CAST STONE3" CLAYBARREL TILE2" STONEBANDINGCASTSTONECAPMETAL VENT2" STONEBANDINGMETAL VENT CAP3" CLAYBARREL TILECAST STONE CAP2" STONE BANDINGCASTSTONE CAP6"X6"CASTSTONE2" STONEBANDTERRA COTTA BRICK3" CLAYBARREL TILESTONE ORSTUCCO VENEERCAST STONEENDCAPCLAY BARRELTILE ROOFCAST STONE FASCIACUT CLAYBARREL TILE412"11"1'-0"33
4"3"21
2"2"412"11"3"6"13
4"2"34"412"112"2'-0"412"112"412"112"412"34"6"3"6"33
4"312"4"COORDINATESPACING WITH CLAYTILE MANUFACTURER8"8"3"1'-6"1" PROJECTIONSTUCCO ORMORTAR FILLED4" DIA. CUT CLAY PIPE123"x4" CEDAR RAFTER TAIL1/4" CEDART&GGYP. BOARDBATT INSUL. -REF. I.E.C.C.CEILING JOIST -REF. STRUCT.PLATE HT.RAFTER - REF. STRUCT.ELEV.12REF.DECKING &BLDR PAPERSTONE VENEER6" HALF ROUNDGUTTERDRIP EDGEBIRD STOPTILE ROOFINGPLUMB CUTFACE OF 2X6BACKER RODCAULKINGSCALESHEETDATEA4.011/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:28 AM, BUSH DESIGN & ASSOC.
BATT INSUL. -REF. I.E.C.C.GYP. BOARDFLOOR JOIST -REF. STRUCT.BATT INSUL. -REF. I.E.C.C.GYP. BOARDSTONE VENEERTRIMMEDROOF TILESTUCCO VENEERFLASHINGPACKEDMORTARTREATED 2X6TREATED 2X4ROUGH 2"-3"THICK STONERANDOM DEPTHRANDOM DEPTHSEE PAGE 57ENTRADA DESIGN GUIDELINESFOR ADD'N INFORMATIONHAND-SHAPEDSTONEHAND-SHAPEDSTONESTONEVENEERWOODPLANKEDDOORHANDFORGEDIRONGRILLVARY MOTORJOINTS TOMAINTAINRADIUS1'-3"1'-3"1'-0"6"9"9"8"R1
'
-
3
"
R9
"SHAVEDBRICK2" RECESSEDSTONEVENEER6"9"9"8"R9"SHAVEDBRICKSHAVEDBRICK1"112"1"2"TERRACOTTABRICKSEE PAGE 57ENTRADA DESIGN GUIDELINESFOR ADD'N INFORMATIONCAST STONEHANDRAILINSUL.REF: I.E.C.C.DECKING &BLDG. PAPERTILE ROOFCONTINUOUSMETAL EDGE2X4 SUB-FASCIA1X4 FREIZE1X4 BLOCKINGSTONE W/ GALV.WALL TIES PERCODERAFTERRAFTERGYP. BOARDGYP. BOARDINSUL.REF:I.E.C.C.EXT. SHEATHING W/WEATHER RESISTANTSHEATHING PAPERRAFTERRAFTERGYP. BOARDGYP. BOARDINSUL.REF:I.E.C.C.INSUL.REF: I.E.C.C.DECKING &BLDG. PAPERTILE ROOFCONTINUOUSMETAL EDGE2X4 SUB-FASCIASTUCCO W/GALV. WALL TIESPER CODEDECO BOLTSDECO BOLTSSHUTTER DOGSILLHEADER1'-0"8"3'-2"METAL HANDRAIL PERENTRADA DESIGN GUIDELINESPRE-CASTCONCRETEBALCONYREF. A4.03 FOR BALCONY NOTE:WROUGHT IRON DESIGNS WATER PROOFINGWEEP HOLE2x BLOCKINGA4.02/13STONE/CASTSTONECORBELHAND SHAVEDSTONECONTINUOUS SILL6"6" OVERLAPTHEN PONY WALLS & P.L. 5/8"IF 4' NO RAFTERS CROSS P.L.DECKING WITH NO 4' FLAREUNDER RAFTERSNOTE:-TWO INTERIOR SHEETS OF 5/8" MUST GOFROM THE SLAB TO THE DECK-POST TENSION CABLES MAY CROSS P.L.REF ELEV.CONC. FOUNDATIONREF. STRUCT.INSULATIONREF. I.E.C.C.REF. STRUCT.REF. STRUCT.1" AIR GAP (TYP.)5/8" FIRE ROCK4' FLARE OF FIREROCK UNDERRAFTERS2X6 JOISTS(JOISTS SHOULD BE RUNPARALLEL TO FIRE WALL)5/8" FIRE ROCKREF. I.R.C. FORVAPORRETARDERREQUIREMENTSBRACED STUD WALLREF. STRUCT.REF ELEV.TREATED WD. PLATERAFTERS4'-0"4'-0"2x FIRE BLOCK4' OUT ON RAFTERDECKING2x FIRE BLOCK4' OUT ON RAFTER2X4 PONY WALL5/8" FIRE ROCK5/8" FIRE ROCK TODECKING BETWEENFIREWALL12" X 1/2" J- BOLT12"1/4" STEEL PLATE1/2" BOLT5"5"4"10"8"2x BLOCKING1/2" OSB/ SHEATHINGSCALESHEETDATEA4.021/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:31 AM, BUSH DESIGN & ASSOC.
CEDARDECO. MACEDAR1X1 DIMOND CLAVOWITH SCEW STUD(CREATIVE RESINS#300-72825)33" SOLID HINGEW/ FLAT END(RUSTIC SERIES#300-72032)4-1/2" RING PULLW/ COORDINATINGCLAVOS(RUSTIC SERIES#300-72100)CEDARCEDAR1X1 DIMOND CLAVOWITH SCEW STUD(CREATIVE RESINS#300-72825)33" SOLID HINGEW/ FLAT END(RUSTIC SERIES#300-72032)4-1/2" RING PULLW/ COORDINATINGCLAVOS(RUSTIC SERIES#300-72100)CEDARCEDAR1X1 DIMOND CLAVOWITH SCEW STUD(CREATIVE RESINS#300-72825)33" SOLID HINGEW/ FLAT END(RUSTIC SERIES#300-72032)4-1/2" RING PULLW/ COORDINATINGCLAVOS(RUSTIC SERIES#300-72100)CEDARCAST STONECLAY BRICKSCLAY BRICKS1'-4"R6"10"SEE PAGE 57ENTRADA DESIGN GUIDELINESFOR ADD'N INFORMATIONCAST STONEBARREL TILECAST STONEBARREL TILEFASCIA BOARD1'-6"CEDAR PLANKS1X1 DIMOND CLAVOWITH SCEW STUD(CREATIVE RESINS#300-72825)CUT LIMESTONESCALESHEETDATEA4.031/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/2016Westlake Re-Submittal3/8/201604/11/20164/20/2016 10:45:34 AM, BUSH DESIGN & ASSOC.
2-14682-20682-266812246826682868DOOR SCHEDULEDOORTYPEINTERIOR345672868STYLEPAIRMATERIALNOTES-891011122-14802-20802-268020802480268028802880308026802-1680EXTERIORINTERIORINTERIOREXTERIORINTERIORINTERIOR1314151617EXTERIORINTERIORINTERIORINTERIOR18EXTERIOREXTERIOREXTERIORINTERIORINTERIORINTERIORINTERIOR2480EXTERIOR19PAIRFRENCHFRENCHPAIRPAIRPAIRCLADUPSTAIRSDOWNSTAIRS9080O. HEAD20ARCHED3050GATE21ARCHEDCLADCLADCLADCLADCLADCLADCLAD2880EXTERIOR22CLADA4.03/01-052-2680GATE23ARCHED12636WINDOW SCHEDULEWINDOWTYPECASEMNTUPSTAIRSDOWNSTAIRS2HEIGHTWIDTH2'-6"3'-6"NOTES2650CASEMNT2'-6"5'-0"32040FIXED2'-0"4'-0"ARCHEDHDR HT6'-8"6'-8"14'-8"42040FIXED2'-0"4'-0"ARCHED16'-4 1/2"52040FIXED2'-0"4'-0"ARCHED18'-1"62040FIXED2'-0"4'-0"ARCHED6'-8"72-1640FIXED3'-0"4'-0"6'-8"MULLED82850CASEMNT2'-8"5'-0"6'-8"3050CASEMNT3'-0"5'-0"6'-8"93050FIXED3'-0"5'-0"6'-8"10112040FIXED2'-0"4'-0"14'-1"122040FIXED2'-0"4'-0"15'-5"132040FIXED2'-0"4'-0"16'-9"142040FIXED2'-0"4'-0"6'-8"152650CASEMNT2'-6"5'-0"8'-0"162040FIXED2'-0"4'-0"8'-0"172040FIXED2'-0"4'-0"13'-11 1/4"182040FIXED2'-0"4'-0"18'-1"192650FIXED2'-6"5'-0"8'-0"203-2660FIXED7'-6"6'-0"8'-0"ARCHED212626FIXED2'-6"2'-6"14'-0"BLCK OUT2230503'-0"5'-0"8'-0"CASEMNT2330503'-0"5'-0"8'-0"FIXED242-20504'-0"5'-0"8'-0"FIXEDMULLEDSCALESHEETDATEA4.041/4" = 1'-0"BUSH DESIGN & ASSOCIATES, INC.
CAN LEGALLY RESULT IN THE CESSATION OF CONSTRUCTION OR BUILDINGS BEING SEIZED AND/ OR MONETARY COMPENSATION TO
AND ELEMENTS OF THE DESIGN. UNDER SUCH PROTECTION, UNAUTHORIZED USE OF THESE PLANS, WORK OR HOME REPRESENTED,
PROTECTION INCLUDES BUT IS NOT LIMITED TO THE OVERALL FORM AS WELL AS THE ARRANGEMENT AND COMPOSITION OF SPACES
17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. THE
COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN "ARCHITECTURAL WORK" UNDER SEC. 102 OF THE COPYRIGHT ACT,
MAY CONFLICT WITH SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS ARE
ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH
COMPLETE ENGINEERING SERVICES, FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. NOTE:
BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN
ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER
STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT.
THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS
COPYRIGHT, BUSH DESIGN & ASSOCIATES, INC. - 2016
PHONE: 972-333-9455EMAIL: ralphbush@hotmail.comPO BOX 456FRANKLIN, TEXAS 77856ISSUE LOGDESCRIPTIONDATEPrelim8/10/2015Westlake Submittal1/18/2016ENTRADA, WESTLAKE
A CATALONIAN VILLAGE
BLOCK: J LOTS 11-16
XXX,XXX,XXX CORTES
XXX CARDONA
XXX,XXX CATALONIAWestlake Re-Submittal2/23/2016Westlake Re-Submittal3/1/201604/11/2016Westlake Re-Submittal3/8/20164/20/2016 10:45:37 AM, BUSH DESIGN & ASSOC.
Design-Project Management-
972-347-9930
Horticulture Services
Davis & State Hwy. 114
Westlake, Texas Date:Scale:Project No.:Drawn by:Approved: Revised:04/08/161" = 20'-0"SOL-1Sheet No.
2 VECES EL DIAMETRO DE LABOLA DE RAIZBOLA DE RAIZ CON ARPILLERA O LONA O EN SU CONTENEDOR2 X DIAMETER OF ROOTBALLB&B OR CONTAINER TRANSPLANTED TREE/ARBOL TRANSPLANTADOTREE PLANTING DETAILNO SCALE/NO ESCALABOLA DE LA RAIZ - DEBE QUEDAR 2"MAS ALTA QUES EL NIVEL FINAL,REMUEVA LA LONA 1/3NIVEL FINAL DESPUES DERASTRILLAR ("REQUEAR")FINISHED GRADEWIRE 1/3 THE DEPTH OF THE ROOT BALLFINISHED GRADE; REMOVE BURLAP ANDROOT BALL - PLANT 2" HIGHER THANSUBSUELO EXISTENTE ONATURAL3" HARDWOOD MULCHBACKFILL PER NOTESEXISTING SUBGRADERELLENAR SEGUNINDICACIONES3" PAJA O PAJOTEBEFORE CONTINUING WORK.BACKFILL & PLANT MATERIAL. NOTIFY OWNER OF RESULTSTEST EACH HOLE FOR PERCOLATION RATE BEFORE INSTALLINGNOTE: DIG ONE CONTINUOUS HOLE FOR EACH SHRUB MASSING.MIN.12"NO SCALE/SIN ESCALA2" DEPTH OF MULCHCONTAINER PLANT12" MIN.TAMPING.IN 6" LIFTS, USING WATER & HANDCOMPACT SOIL BELOW ROOT BALLSFINISH GRADESET TOP OF ROOT BALL 1" ABOVEFINISH GRADEMIXTURE OF EXPANDED SHALE & COMPOSTPREPARE PLANTING BED WITH 2" OF A 50/50ROOT SYSTEM.OUTER ROW OF PLANT MATERIALEXCAVATE HOLE 12" BEYONDSPACE PLANTS PER PLANB & B PLANTSHRUB BED PREPARATION & SHRUB PLANTING/ESPACIO ENTRE PLANTASSEGUN PLANONOTA: HAGA UN POZP CONTINUO PARA CADA ARBUSTO O PLANTA.COMPRUEBE EL RANGO DE TRANSMINACION ANTES DE RELLENAR YPLANTAR EL MATERIAL. NOTIFIQUE AL PROPEIRTARIO DE LOSRESULTADOS ANTES DE SEGUIR TRABAJANDO.PLANTA DEL CONTENEDORLONA Y BOLA DE RAIZDE LA PLANTANIVEL FINALCOLOCA LA BOLA DE RAIZ1" ARRIBA DEL NIVEL FINALEXCAVAR 12" FUERA DE LA LINEADE LA BOLA DE RAIZ DELMATERIAL A PLANTAR2" DE PAJA O PAJOTE (MULCH)PREPARAR CAMA PARA PLANTACIONRELLENAR SEGUN ESPECIFICACIONESDEJAR 6" DE TIERRA PREPARADA BAJO LABOLA DE RAIZ; COMPACTARLA USANDOAGUA Y COMPACTADOR DE MANOPREPARACION PARA CAMA DE PLANTAS Y PLANTACIONDE ARBUSTOS O PLANTASTYPICAL GROUNDCOVER PLANTINGSURFACE W/OUT EDGINGMIN. 4" TILLED DEPTH-ALL BEDSFINISHED LAWN W/ EDGING (TRIANGULAR SPACING)MIN.4"PER DETAIL OR HARD1" COMPOST OR MULCHEXISTING SOILOF EXPANDED SHALE & COMPOSTWITH 2" OF A 50/50 MIXTURE1"SEE PLANS FOR SPACING(NO WEED CLOTH) TYP.O.C. SPACINGEQUAL/SPACING1/2 O.C.2 X O.C.SPACING TYP.
TYP.
O.C.SPACING
18" OR LAWNHARD SURFACEFIRST ROW/EQUAL/
EQUAL/
TYP.
O.C.SPACINGVER PLANOS PARA ESPACIOENTRE PLANTAS1" DE ABONO O PAJA (NO TELAPARA HIERBA MALA)CESPED TERMINADO CON BORDESEGUN DETALLES O SUPERFICIEDURA (BANQUETA, MADERA, ETC.)MINIMO REVOLVER O TRILLAR TODAS LASCAMAS A 4" DE PROFUNDIDAD CON ABONO OENMIENDAS SEGUN ESPECIFICACIONESSUELO O TIERRA EXISTENTE1/2 DISTANCIADEL CENTROEQUIVALENTE O IGUALDISTANCIA DEL CENTRO2 VECES EL ESPACIAMIENTO
DEL CENTROPRIMERA LINEASUPERFICIE DURA O CESPEDTIPICA PLANTACEAN DE CUBIERTA DE TERRENO(ESPACIAMINETO TRIANGULAR)NO SCALE/SIN ESCALAIGUAL
IGUAL
IGUALEQUAL/IGUAL120 DEGREES AROUND TREEMETAL STAKES AT(3) 2"x2" WOOD OR TURNBUCKLETIGHTENING STICK ORHOSE AT TRUNKREINFORCED RUBBEROR CINCH TIE14 GA. WIRE TWISTED;TO MAX. 54"2/3 HT. OF TREEmin.15"STAKING DETAILS/DETALLE PARA ESTACANDONO SCALE/MECHANICALTRANSPLANTED TREETO MAX. 54"2/3 HT. OF TREETIGHTENING STICK OR(3) 2"x2" WOOD OR METAL STAKES AT120 DEGREES AROUND TREE14 GA. WIRE TWISTED;TURNBUCKLEOR CINCH TIEREINFORCED RUBBERHOSE AT TRUNKB&B OR CONTAINER TRANSPLANTED TREEMANGUERA DE PLASTICOEN EL TRONCOALAMBRE CALIBRE 14RETORCIDOO SINCHO ESTIRADOESTACA PARA APRETAR OVARILLA GIRATORIA(3) BARROTES 2" X 2" OESTACASDE METAL A 120 GRADOSALREDEDOR DEL ARBOLMANGUERA DE PLASTICOEN EL TRONCOALAMBRE CALIBRE 14RETORCIDOO SINCHO ESTIRADOESTACA PARA APRETAR OVARILLA GIRATORIA(3) BARROTES 2" X 2" OESTACASDE METAL A 120 GRADOSALREDEDOR DEL ARBOL2/3 DE LA ALTURADEL ARBOLMAXIMO 54"ARBOL TRANSPLANTADO EN SU CONTENEDOR OBOLA DE RAIZ CON ARPILLERA O LONAARBOL TRANSPLANTADO DE MAQUINAL2/3 DE LA ALTURADEL ARBOLMAXIMO 54"SIN ESCALA1L22L23L24L25L2Design-Project Management-
972-347-9930
Horticulture Services
Davis & State Hwy. 114
Westlake, Texas Date:Scale:Project No.:Drawn by:Approved: Revised:04/08/16NTSSOL-2Sheet No.SHEPHERD WALL DETAILNO SCALE/6L2